INSTALLATION/MAINTENANCE ADVICES: 

In case the sounder does not work properly, verify if the LED located on the main board is flashing. 
If it flashes, check the ANOMALY NOTICE CHART above. 
 
MOUNTING: 

1.

 

Screw the sounder on the wall and check if the tamper works properly; 

2.

 

Insert the connection cables through the holes localed on the sounder base; 

3.

 

If necessary, modify the default settings acting on the DIPSWITCHES as indicated in the charts here above; 

4.

 

Connect the battery and the power supply to the control panel; 

5.

 

Close both internal and external covers using the screws provided; 

6.

 

Battery must have UL94-HB flammability rate;  

7.

 

Power supply must be of SELV type. 

 

Attention:  not  to  have  condensation  in  the  sounder,  it  is  important  to  avoid  any  air  flow  inside  the  duct.  To  such  purpose,  once  the 
sounder is connected, seal the hole using some silicon or any other plaster. This operation prevents condensation from forming inside the 
sounder; condensation mostly appears in winter and it is usually caused by warm and humid air coming out of the wall where the sounder 
is installed and passing through the holes located on the sounder base. 
 
 
 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 

 

 

 

 

 

 

 

 

 

 

 

117.1 dB (Rialto LSX) 
115.0 dB (Triade L/Lido LS) 
115.5 dB (Rialto LS) 

Diagram 1 

Summary of Contents for RIALTO L

Page 1: ...timings alarm counting optical and acoustic signaling of System ON OFF arming disarming electronic circuit protected against polarity inversion and tropicalized by resin immersion microprocessor self...

Page 2: ...TERMINAL NEGATIVE INPUT FOR SOUND BLOCK It activates the sound interruption trigger by taking a negative 0V to terminal no 4 D STI TERMINAL SYSTEM STATUS NOTICE PERMANENT MOMENTARY ALARM SYSTEM ON OFF...

Page 3: ...5 STI to 12V for 10 seconds then take away the voltage from the terminal These steps launch the test which will last 60 seconds During the test the sounder verifies its own functioning and notifies an...

Page 4: ...ive missing alarm if disconnected or 0V ON Negative missing alarm if disconnected or 12V Chart 6 TONE SELECTION DIP 4 TONE FREQUENCY LIMITS Hz OFF default setting CERTIFIED Increasing Continuous Decre...

Page 5: ...nd the power supply to the control panel 5 Close both internal and external covers using the screws provided 6 Battery must have UL94 HB flammability rate 7 Power supply must be of SELV type Attention...

Page 6: ...5 mA Vc 12V 0 3 mA Vc 0V Open collector 10mA max LED flashing unit life 1 000 000 flashes Timing 3 minutes settable at 8 minutes Battery capacity 12V 2 0 Ah Switch tamper range N C 0 2 A max Fundament...

Page 7: ...MA SE RTL0 03 01 Manuale Rialto Triade Lido Eng rev1 Page 7 of 8 NOTE...

Page 8: ...MA SE RTL0 03 01 Manuale Rialto Triade Lido Eng rev1 Page 8 of 8 Via del Lavoro 10 30030 Salzano VE Tel 39 041 5740374 Fax 39 041 5740388 Web site www venitem com E mail info venitem com...

Reviews: