33
DELETION: To delete a connected device, proceed by sending the SMS “CSnn, where “nn” stands for the
zone number corresponding to the device to be deleted. For example: SMS “CS01” (to remove the device
corresponding to zone 1). You will receive an SMS to confirm the correct deletion.
ZONES CONFIGURATION: To configure zones, an SMS with all zones configuration has to be sent: SMS
“LT?
L1.L2.
…. .
L18
?”, where L1-6 stand for the 16 wireless zones and L17-18 for the 2 hardwired
zones. Fields marked in red must be filled up with the desired options for each zone, according to the
chart below:
ZONE 1-16
ZONE 17-18
Magnetic reed + SWALL inputs ON
a
-
Infrared ON
a
-
Only magnetic reed ON
i
-
Only SWALL input ON
e
-
CTH-18 hardwired zone ON
-
a
Zone OFF for partial mode
p
p
Delayed zone
r
r
Balanced zone
-
b
System total armed
-
n
System disarmed
-
f
For example: “LT?apr.apr.i.ep.a.a.a.a.a.a……apb.ar?”. In this case zones 1 and 2 activate the magnetic
reed and the additional SWALL input – the zones are OFF for partial mode; zone 3 is ON only on
the magnetic reed; zone 4 is ON on the additional SWALL input and OFF for partial mode; zones
5,6,7,8,9,10 are infrared sensors; zones 11,12,13,14,15,16 are programmed; zone 17 is ON but
deactivated for partial mode and balanced; zone 18 is ON and delayed.
ZONES CONFIGURATION DISPLAY: To receive the zones configuration, you just need to send the SMS
“VL”.