27
INSERTING THE MICRO-SIM CARD
A
B
INSERTING THE MICRO-SIM
FOLOWING THE SHAPE
AND DIRECTION OF THE SLOT
C
HOLES FOR
THE WIRING
FIXING
HOLES
FIXING
HOLES
FIXING
HOLES
FIXING
HOLES
FLASH COVER
REMOVAL
COVER FIXING
SCREW
ATTENTION:
BEFORE INSTALLING THE MICRO-SIM IN THE ALARM CONTROL PANEL, MAKE SURE THAT
THE PIN IS DEACTIVATED.
1. Open the slot and insert the micro-SIM;
2. Close the slot until you feel it click
(
NOTE
: IF THE SLOT IS NOT PROPERLY CLOSED, THE SIM WILL
NOT MAKE CONTACT AND THE CORRECT FUNCTIONING WILL BE COMPROMISED)
;
220V TERMINAL BLOCK CONNECTION
N.C.
GND
N.O
.
C.
+12V
RELÈ
OUT1
100
mA
L 17
L 18
TA
M
P
STI
OC 1
OC 2
+ –
500
mA
GND
GND
+12V
MICRO-SIM SLOT
FLASHING UNIT
CONNECTOR
GSM ANTENNA
CONNECTOR
ANTI-FOAM
CONNECTOR
TAMPER
CONNECTOR
BATTERY/ LOUDSPEAKER
CONNECTOR
SUPPLY
CONNECTOR
1
2 3
4
5 6 7 8 9 10 11 12 13 14
N.C.
GND
N.O.
C.
+12V
RELÈ
OUT1
100
mA
L 17
L 18
TAMP
STI
OC 1
OC 2
+ –
500
mA
GND
GND
+12V
GSM STATUS LED
N.C.
GND
N.O.
C.
+12V
RELÈ
OUT1
100
mA
L 17
L 18
TAMP
STI
OC 1
OC 2
+ –
500
mA
GND
GND
+12V
5,6 Kohm
RESISTOR
L
N
T630mA
FUSE
NOT USED
POWER SUPPLY
14.5V 0.8V
DEVICES
DEVICES
CASE A: NC WIRING
CASE B: SINGLE-ENDED
BALANCED WIRING
ATTENTION:
PROCEED TO THE NECESSARY WIRING BUT DO NOT
GIVE ELECTRICAL SUPPLY TO CTH-18
Mains connection must respect the installation norms in force in the Country of reference. In particular,
as indicated in the current regulations, an automatic overcurrent circuit breaker with high interruption
power (1500°) has to be located upstream with respect to the connection of the terminal board. Connect
230Vac 50Hz mains cable to the dedicated terminal block respecting phase and ground wires order, as
shown in the picture. The terminal block is equipped with a T630mA fuse.
MINI BUZZER
CTH-18 is equipped with a mini buzzer in the terminal block as acoustic communicator during
configuration. It can be removed at the end of configuration.