6123
H200
7-7-98A
1-16-02B
INST INSTRUCTIONS
VP/VC-6D, VP/VC-6R
SUPERCEDES
TITLE
DATE
SECTION
10. Dash Control Switch Installation: See Dwg. 40124
- Install dash mounting plate under the dash in a convenient location for operator control.
Use the #12 pan head slotted screws, 1/2" long, furnished in kit.
- Install switch extension onto toggle switch.
- Connect center post of switch to the 20 amp in-line fuse.
Connect fuse to hot lead under dash.
- Connect the 16/2 SJO cable in the following manner:
Connect one wire lead to top pole, and the other lead to the lower pole of switch. Run cable
to the power unit.
Single Acting: See Dwg. 6133B, 6506, 6507.
Double Acting: See Dwg. 6096, 6493, 6500.