System operating hours
It is possible to display the operating hours
of the system (relay in ON status).
Field
(7)
displays the writing
“ tot= ”
while
fields
(11)
and
(8)
dispaly the timing value
(this value consists of 5 digits, 3 on field
(11)
and 2 on field
(8)
and the reading
direction is from left to right. In the example
the value is 1274 hours).
There are two indipendent totalizers for
winter and summer operating mode. The
maximum storable value is 65535 hours.
To reset the counter, press the key
“ ”
for about 3 seconds in the counter
display menu.
ADVANCED FUNCTIONS
Emergency regulation
In winter operating mode if the sensor is failed, the thermostat activates the relay
for 10 minutes every 4 hours in order to avoid problems due to freezing and field
(8)
displays the symbol
“ --- ”
.
Restoring default values
Just pressing the key
“ R ”
do not cause a total reset of the instrument. To reset
the instrument and restore the default values, it is necessary to press the key
“ R ”
then the key
“ ”
within 3 seconds. The display shows the writing
“dEF”
.
Note: In this way, also the remote operating settings (stored numbers,
recipient of alarm, etc.) are reset (see “Gsm interface” page 21).