background image

Thermostat installation location recommendations  .  .  . 2
Thermostat mounting .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 2
Equipment control module installation location 

recommendations .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 2
Equipment control module mounting   .  .  .  .  .  .  .  .  .  .  .  .  .  . 2
Thermostat wiring   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 3
Remote temperature sensor (optional)   .  .  .  .  .  .  .  .  .  .  .  .  . 3
Equipment control module wiring  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 4
Outdoor temperature sensor (included) .  .  .  .  .  .  .  .  .  .  .  .  . 5
Optional wireless outdoor temperature  

and humidity sensor .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 5
Return air temperature sensor (optional)   .  .  .  .  .  .  .  .  .  .  . 6
Leaving air temperature sensor (optional)   .  .  .  .  .  .  .  .  .  . 6

TABLE OF CONTENTS

INSTALLATION

HVAC WIRING DIAGRAMS

INDOOR AIR QUALITY WIRING DIAGRAMS

POWER & RESET OPTIONS

SETUP & TESTING

REFERENCES

Power and reset options   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 10

Installer setup wizard   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 10
HVAC installer system settings tables   .  .  .  .  .  .  .  .  . 10-12
   General system settings table  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 10
   Thermostat system settings table   .  .  .  .  .  .  .  .  .  .  . 11-12
Indoor Air Quality system settings tables .  .  .  .  .  .  . 13-16
   Humidifier system settings table  .  .  .  .  .  .  .  .  .  .  .  . 13-14
   Dehumidifier system settings table  .  .  .  .  .  .  .  .  .  .  .  .  . 14
   Air cleaning system settings table .  .  .  .  .  .  .  .  .  .  .  .  .  . 15
   Fresh air system settings table   .  .  .  .  .  .  .  .  .  .  .  .  . 15-16
Installer system test   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 16
Wi-Fi setup .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 16

Quick reference to controls & display .  .  .  .  .  .  .  .  .  . 17-18
Thermostat features   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 18
Troubleshooting   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 19
Specifications .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 20

Conventional heat/cool single transformer .  .  .  .  .  .  .  .  .  . 7
Conventional heat/cool two transformer   .  .  .  .  .  .  .  .  .  .  . 7
Heat pump single transformer .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 8
Heat pump two transformer   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 8

Indoor Air Quality wiring with separate transformers  .  .  . 9
Indoor Air Quality wiring with a single transformer .  .  .  .  . 9

Safety & Installation 
Instructions

Model 8920W Touch Screen  

Wi‑Fi Thermostat with Integrated 

Indoor Air Quality Solutions

READ AND SAVE THESE INSTRUCTIONS

61000995 B2205906G 10.18

English

 1

Summary of Contents for 8920W

Page 1: ...bles 10 12 General system settings table 10 Thermostat system settings table 11 12 Indoor Air Quality system settings tables 13 16 Humidifier system settings table 13 14 Dehumidifier system settings table 14 Air cleaning system settings table 15 Fresh air system settings table 15 16 Installer system test 16 Wi Fi setup 16 Quick reference to controls display 17 18 Thermostat features 18 Troubleshoo...

Page 2: ...perature sensor should be mounted On an interior wall in a frequently occupied space Approximately 5 above floor At least 18 from outside wall Using less than 300 of wire Do not mount remote sensor Behind doors in corners or other dead air spaces In direct sunlight near lighting fixtures or other appliances that give off heat On an outside or unconditioned area wall In the flow of a supply registe...

Page 3: ...2 sensor to the ODT terminals and enabling the outdoor sensor in the installer setup menu When an outdoor sensor is installed the features below will be enabled In heat pump mode the outdoor temperature sensor can be used to efficiently utilize an air source heat pump When the outdoor temperature is less than the Low Balance Point the heat pump will be locked out and only auxiliary heating will be...

Page 4: ...OLING LOCATE SENSOR IN SHADED AREA CONVENTIONAL HEAT COOL TWO TRANSFORMER REMOVE JUMPER HEATING TRANSFORMER COOLING TRANSFORMER C R W W2 B Y Y2 O G L RH RC C 3 EQ HP HC G Y3 Y2 Y W3 W2 W TRANSFORMER THERMOSTAT 1 2 2nd COOLING 1st COOLING FAN 1st HEATING 2nd HEATING 3rd HEATING 3rd COOLING 1 R and C can be powered from the HVAC equipment transformer or any other constantly powered 24VAC source 1 RE...

Page 5: ...FAULT DETECT REVERSING VALVE REVERSING VALVE 2nd HEATING 1st HEATING FAN 1st COMPRESSOR 2nd COMPRESSOR 2 1 1 R and C can be powered from the HVAC equipment transformer or any other constantly powered 24VAC source INDOOR AIR QUALITY WIRING DIAGRAMS INDOOR AIR QUALITY WIRING WITH SEPARATE TRANSFORMERS INDOOR AIR QUALITY WIRING WITH A SINGLE TRANSFORMER TRANSFORMER TRANSFORMER TRANSFORMER VNT DH HUM ...

Page 6: ...compressor stages Heat Pump mode only One Two Number of Auxiliary Heat Stages Select number of auxiliary heat stages Heat Pump mode only One Two Number of Stages of Heat Select number of heat stages Heat Cool mode only One Two Three Number of Stages of Cool Select number of cool stages Heat Cool mode only One Two Three Remote Temperature Sensor Installed Select if the remote sensor is attached and...

Page 7: ...ettings are only present dependent upon the value of other settings The use of an outdoor temperature sensor recommended enables additional Indoor Air Quality functionality Please refer to the Model 8920W Owner s Manual for further information about thermostat features Note Refer to manuals for humidifier dehumidifier air cleaner and ventilation products for recommended installation and operation ...

Page 8: ...y default setting bold and setting range Fresh Air Vent Installed Selects if ventilation is installed If set to No no other ventilation settings will be available No Yes Display Button Note only available if Fresh Air Installed is set to No Yes No Fresh Air Setup Type Selects if ventilation is configured through the Code setup or Comfort Comfort setup has more lockout options Code setting ensures ...

Page 9: ...MPERATURE SCALE LOCKOUTS AWAY MODE SETTING IF ENABLED AWAY MODE STATUS IF INSTALLED FAN MODE SELECTION CLEAN DISPLAY TOUCHSCREEN IS OFF FOR 30 SECONDS ROOM TEMPERATURE HUMIDITY HEAT SETTING THERMOSTAT NAME System setting Description Factory default setting bold and setting range Enable Low Vent Temperature Limit Enables low ventilation temperature lockout limit Only available if Outdoor Sensor is ...

Page 10: ...ting Equipment Type to make sure it is set to match the installed heating cooling equipment HEATING IS NOT DISPLAYED Check Installer Setting Control Setup is set correctly Change the System Mode to Heat and set the temperature level above the current room temperature COOLING IS NOT DISPLAYED Check Installer Setting Control Setup is set correctly Change the System Mode to Cool and set the temperatu...

Page 11: ... to 50 R H Dehumidification 40 to 90 R H SPECIFICATIONS Electrical Operating voltage 24VAC 18 30VAC Current Maximum 2 5A total 1 0A single output Maximum surge current 5A Environment Temperature shipping 30 to 150 F 34 to 65 C Temperature thermostat operating 32 to 120 F 0 to 48 C Temperature equipment control module operating 32 to 158 F 0 to 70 C Relative humidity Operating 5 to 90 R H non conde...

Reviews: