background image

La Crosse Technology, Ltd.  

Page 1 

 

W S-1025 FAQS  

 

The links below will work in most PDF viewers and link to the topic area by clicking the link. We 
recommend Adobe Reader version 10 or greater available at:  

http://get.adobe.com/reader

  

 

T ABLE OF  CONT E NT S 

WS-1025 FAQS ......................................................................................................................... 1 

Batteries..................................................................................................................................... 1 

Thermometer Factory Restart .................................................................................................... 1 

Window Thermometer ................................................................................................................ 2 

Power requirements ............................................................................................................... 2 

Set Time ................................................................................................................................. 2 

Can I view temperature in Celsius? ........................................................................................ 2 

Dashes, OF.L or stuck Temperature ....................................................................................... 2 

Time is off by hours. ............................................................................................................... 2 

Mount on Window ................................................................................................................... 2 

Remove from Window ............................................................................................................ 2 

Accuracy ................................................................................................................................ 2 

Thermometer is Dim. .............................................................................................................. 3 

Thermometer has a Distorted Display. .................................................................................... 3 

Thermometer has missing segments. ..................................................................................... 3 

Thermometer Display appears Frozen.................................................................................... 3 

Thermometer is Blank: No letters, numbers or dashed lines. .................................................. 4 

 

 

Batteries 

 

  Half of all warranty issues can be resolved with fresh batteries of the appropriate voltage.  

  We suggest name brand alkaline batteries.   

  Use batteries dated at least six years in advance of the current year. Batteries dated earlier 

than six years from now may still work, but may be unstable in performance.   

  Alkaline batteries manufactured this year will have an expiration date 10 years in the future. 

Battery technology has improved and batteries will maintain voltage longer in storage. 
However, the environment the batteries reside in for the 10 years can deplete the power. 

  Good name brand batteries make less noise, which reduces the chance of RF (radio 

frequency) interference from the battery compartment. A minimum voltage of 1.48V for each 
battery is necessary for proper performance.  

 

Thermometer Factory Restart 

  

1.  Remove the battery for 15 minutes.  
2.  Press one of the buttons at least 20 times to clear all memory.  
3.  Insert a fresh battery into the thermometer.  
4.  Do not press buttons for 15 minutes. 

 

 

Summary of Contents for WS-1025

Page 1: ...th fresh batteries of the appropriate voltage We suggest name brand alkaline batteries Use batteries dated at least six years in advance of the current year Batteries dated earlier than six years from now may still work but may be unstable in performance Alkaline batteries manufactured this year will have an expiration date 10 years in the future Battery technology has improved and batteries will ...

Page 2: ... hours This thermometer has manual set time Mount on Window Thoroughly clean the window where the thermometer holder will attach Remove the mounting bracket from the thermometer by firmly grasping the edges and pulling strait back Attach the mounting bracket to the outside of the window with the enclosed adhesive tape Hang the thermometer on the bracket by firmly pressing onto the mounting bracket...

Page 3: ...d the thermometer should be blank If numbers still appear please check for scratch guard Check that the batteries are installed correctly Batteries may be overpowered or underpowered Remove batteries from Wireless Thermometer Press any button 20 times Leave the batteries out of the display for 2 hours Insert fresh batteries into the wireless thermometer Thermometer has missing segments This is gen...

Page 4: ...ashed lines Check that the batteries are installed correctly Batteries may be overpowered or underpowered Remove batteries from wireless thermometer Press any button 20 times Leave the batteries out of the display for 2 hours Insert fresh batteries into the wireless thermometer ...

Reviews: