IMPOSTA ALLARME MASSIMA restores the current configuration for the
maximum threshold
IMPOSTA ALLARME MINIMA restores the current configuration for the minimum
threshold
Some examples:
IMPOSTA ALLARME MINIMA INT 12 2 30 generates a minimum alarm if the
temperature measured by the internal
probe goes below 12°C for at least 30
minutes and considers the alarm restored
when the temperature exceeds 14°C
(12+2).
IMPOSTA ALLARME MASSIMA EXT 28.5 1.5 50 generates a maximum alarm if
the temperature measured by the
external probe exceeds 28.5°C for
at least 50 minutes and considers
the alarm restored when the
temperature goes below 27°C
(28.5-1.5).
Note: the alarm return is immediate when the alarm return temperature is
reached (no delay)
Power supply failure alarm
In the case of a power supply failure, the Mithos GSM RF has a backup battery that
permits operation of the chronothermostat for approx. one hour.
The recipients of this alarm will receive the following message in the case of power
network failure and restoration:
ALLARME ALIMENTAZIONE=INTERROTTA (gg/mm/aa hh:mm)
FINE ALLARME ALIMENTAZIONE=RIPRISTINATA
(gg/mm/aa hh:mm)
By default, the number in the telephone book with index 1 receives the network
failure alarm.
Note: the alarm message is not sent instantaneously, but there is a delay
of a few seconds (signaled by the flashing symbol), to make sure the
device has a stable GSM connection.
Summary of Contents for Mithos GSM RF
Page 1: ...Cronotermostato Digitale Mithos GSM RF Manuale d Uso User Manual DIGITAL CHRONOTHERMOSTAT...
Page 2: ......
Page 56: ......
Page 59: ......