![Vemer Mithos GSM RF User Manual Download Page 12](http://html1.mh-extra.com/html/vemer/mithos-gsm-rf/mithos-gsm-rf_user-manual_4041136012.webp)
English
- 10 -
Mithos GSM RF Chronothermostat User Manual
INITIAL START-UP / RESET
Mithos GSM RF is a chronothermostat thought to be controlled remotely via SMS or
APP. To make this possible, it is necessary to have a SIM card of a telephone operator
to ensure a good coverage of GSM signal receiving.
1. Connecting the Mithos GSM RF to the GSM network
Mithos GSM RF is able to determine which operator ensures the best GSM coverage in
the area of installation.
Testing the GSM signal intensity
1. Turn on the Mithos GSM RF and make sure that no SIM card is inserted in the
housing
2. Press the
“R”
key and right after the
“ ”
key
3. The display shows
“FLD”
and then a screen like this:
Identifying operator
Operator name
01 – 43 – 48
TIM
10 – 06
VODAFONE
88 – 44
WIND
99 – 33
3
4. Press the
“ ”
and
“ ”
keys to
scroll and check the intensity of the
signals of all detected operators.
5. To exit, press the
“R”
key
It is advisable to choose a SIM card of the
operator with the highest signal intensity.
Requirements of the SIM card
– It must be enabled to telephone traffic (voice, not SIM data)
– it must have the PIN code request disabled (if necessary use a mobile phone to
disable the request)
– it must have the voice mail disabled
Identificativo
operatore
Intensità del segnale
Progressivo
operatore rilevato
Progressive
detected operator
Identifying
operator
Signal intensity