background image

Digital

chronothermostat

Dafne Wi-Fi 

User manual

Summary of Contents for Dafne Wi-Fi

Page 1: ...Digital chronothermostat Dafne Wi Fi User manual ...

Page 2: ......

Page 3: ... the device from your account Page 25 Q Configuration without remote control Page 26 Q Programming menu Page 28 Time and date modification Page 28 Programs modification Page 29 Temperatures modification T1 T2 T3 Page 30 Timing setting Page 32 Advanced functions menu Page 33 Q Manual operation Page 39 Q Off operation Page 40 Q Backlighting management Page 41 Q Minimum and maximum values Page 41 Q Summe...

Page 4: ... bedrooms The integrated Wi Fi module allows you to control the device remotely using your smartphone or tablet It is necessary to connect the device to the home router and install the appropriate app on your smartphone or tablet available free of charge for iOS and Android devices The device connects to the Vemer cloud to check if there are any changes to the configuration and schedule created us...

Page 5: ...and 230V power supply 7 programs available for heating operation 7 programs available for cooling operation Integrated Wi Fi module that allows you to remotely control the device using your smartphone or tablet it is necessary to connect the device to the home router and install the appropriate app on your smartphone or tablet available free for iOS and Android devices Flush mounting in three modu...

Page 6: ... Do not power or connect the device if any part of it is damaged 3 After installation inaccessibility to the connection terminals without appropriate tools must be guaranteed 4 The device must be installed and activated in compliance with current electric system standards 5 Before accessing the connection terminals verify that the leads are not live 6 In the electrical system of the building where...

Page 7: ...English 5 Dafne Wi Fi Chronothermostat User Manual DAFNE WI FI MOUNTING Bticino Living series Light Light Tech Livinglight Axolute Vimar Eikon series Eikon Evo Plana Ave S44 series ABB Mylos series A ...

Page 8: ...English 6 Dafne Wi Fi Chronothermostat User Manual DAFNE WI FI MOUNTING ABB Chiara series Vimar Arké series B ...

Page 9: ...English 7 Dafne Wi Fi Chronothermostat User Manual DAFNE WI FI MOUNTING Gewiss Chorus series B Remove the cogs ...

Page 10: ...English 8 Dafne Wi Fi Chronothermostat User Manual DAFNE WI FI MOUNTING Bticino Matix series B BM Remove the cogs ...

Page 11: ...English 9 Dafne Wi Fi Chronothermostat User Manual DAFNE WI FI MOUNTING Vimar Idea series VI B ...

Page 12: ...tat User Manual DAFNE WI FI MOUNTING Bticino Livinglight AIR series AIR Note if the box extension is not present adapter which increases the depth of the flush mounting box we recommend you using the frame for Livinglight AIR installation ...

Page 13: ...English 11 Dafne Wi Fi Chronothermostat User Manual DAFNE WI FI MOUNTING Bticino Axolute AIR series AXO AIR mount not included in the package purchasable as an accessory AXO AIR ...

Page 14: ...hronothermostat User Manual DAFNE WI FI MOUNTING Bticino Living Now series Vemer frame and front panel not included in the package which can be purchased as accessories with dedicated mounting KIT FRONT PANEL VEMER FRAME VEMER ...

Page 15: ...et delays activation of 15 30 45 minutes independent for each hour 5 settable temperatures T1 T2 T3 in automatic operation Tm in manual operation Toff in off mode antifreeze Measured temperature display 0 50 C Measurement precision 0 5 C Measured temperature resolution 0 1 C Setpoint range 2 50 C Clock precision 1 second day Key lock by password Backlight display desactivable Operating frequency b...

Page 16: ...g T1 T2 T3 Timings menu Advanced programming menu Synchronization with Vemer Cloud settings in progress Active Wi Fi network connection Time and minutes Load activation in summer cooling mode Program on graphic for the current day in automatic operation Manual operation activation Load activation in winter heating mode Measured environment temperature Not used Off operation DISPLAY AND KEYBOARD ...

Page 17: ...I plastic elements BM mount A mount B mount AIR Q Keyboard The keys carry out different functions on the basis of the instrument status and they will be described step by step in this user manual There are two types of pressure brief pressure long pressure with duration higher than 3 seconds Q Cleaning the display To clean the display use a soft lint free cloth without using excess force ...

Page 18: ...do the following 1 Install and start the Clima Wi Fi app on your smartphone or tablet 2 Choose Register and fill in the e mail and password fields Note for security reasons it is recommended to choose a password different from the one used to access your e mail box 3 Check your e mail box confirm the activation of the account by clicking on the link contained in the e mail sent by the system 4 Log in...

Page 19: ... diagrams shown in this manual Fix the device inside the 3 modules box in compliance with the assembly diagrams described at the beginning of this manual The accessories for the installation included in the package allow the mounting of the plates described in the diagram adjustable plates and they are mount A mount B according to the needs it could be necessary to remove the side cogs mount AIR c...

Page 20: ...ser through the configuration of the Dafne Wi Fi 4 Select the iwm network to connect to the network generated by the device Wait for the device display to show the icon to indicate the successful connection between the app and the device 5 On the next screen choose the home Wi Fi network to connect the Dafne Wi Fi to Enter the password of the home Wi Fi network and confirm Important before proceedin...

Page 21: ...e iwm network generated by the device by accessing the iPhone s Wi Fi settings Wait for the Wi Fi icon to appear on the iPhone or iPad display and tap Next Wait for the device display to show the icon to indicate the successful connection between the app and the device 5 Enter the full name of the home Wi Fi network to which to connect the device and the password and click Next Important before pr...

Page 22: ...e Wi Fi device remotely easily and intuitively Access using the access credentials email password chosen during registration phase of your account identifies a device or created group allows you to record a new device allows you to group several devices Page Devices list APP DESCRIPTION Page Login ...

Page 23: ...indicates that the program can not be modified or canceled This screen shows the Dafne Wi Fi status indicates the measured temperature 25 0 C the operating mode Heating the system status red on gray off indicates the set temperature and running program name touch this area to access the program list indicates operating mode touch this area to change the operating mode heating cooling and mode autom...

Page 24: ...ee available tempe rature T1 T2 and T3 marked by blue green and red colours Created a program for a day it s possible to copy it to any other day of the week Copy function It is also possible to set a switching delay by tapping on the desired time Note the image refers to the version of the app for smartphone On the tablet the whole weekly programming is visible on a single screen Modify a program...

Page 25: ...the name of Dafne Wi Fi modify the icon that identifies it set the themperature values T0 T1 T2 and T3 NOTE the chronothermostat is compatible with Google Home and Amazon Echo By the association with Google or Amazon account is possible to interact with the device by giving voice commands by speaking to the Voice Assistant via the voice activated speaker Dafne Wi Fi settings ...

Page 26: ...tivates local operation In this way the device does not check if there are new settings on the cloud and adjusts the temperature according to the settings entered from the keyboard the programming and configuration on the cloud are not changed Advanced settings access the screen for setting the temperature blocking local operation choosing the time zone or setting the temperature compensation enter...

Page 27: ...ecause the device is installed in a rented home and tenants change Proceed as follows 1 Disconnect the device from the old user using one of the following two alternatives a Access the Wi Fi signal strength page ADV G menu see page 36 and while the icon flashes hold down the and keys for a long time until the display shows G b From the old user s app on the device list screen long tap on the icon t...

Page 28: ...ent to choosing 1 7 21 The device asks to enter the date and time enter the parameters seconds only synchronization at value 00 minutes hours year month day Use the and keys to increase and decrease the values and the key to confirm and move to the next parameter Once all the values have been set long press 3 seconds the key to exit the clock synchronization menu CONFIGURATION WITHOUT REMOTE CONTRO...

Page 29: ...onothermostat requires the time and date insertion If once you set the device without Wifi remote control Q W R no value is set within about half a minute the chronothermostat starts to operate in the off mode indicated on the display by the icon The lack of time is indicated by the time flashing 12 00 The chronothermostat remains in off operation condition until when the hour is not inserted ensuri...

Page 30: ...the keys and to modify the values and the key to confirm and move to the next parameter for seconds it s possible only the synchronisation at value 00 4 Once all parameters are set to exit and go back to the programming menu press for a short time the key To exit and go back to the normal operation automatic manual press for a long time the key or wait for the time out expiration 30 seconds about I...

Page 31: ...2 2 Press briefly the key until the symbol flashes and press the key to access the parameters modification 3 The programs page is displayed the first day of the week DAY 1 flashing the current program for example P1 of the current operation mode or and the profile that corresponds to the program 3 1 If the set program is good move to the next day with the keys and 3 2 If the set program is not good pres...

Page 32: ...shes field 3 set with the keys and the delay and press the key to move to the next hour 4 When the program satisfies the user s needs go back to the days page pressing twice the key and repeat for the other days of the week the operations just described When all modifications have been performed exit the programming menu by pressing for a long time the key Temperature modification T1 T2 T3 To modify t...

Page 33: ...keys and and press the key to go back to the page of T1 temperature 6 Once all parameters are set to exit and to o back to the programming menu press for a short time the key To exit and to go back to the normal operation press for a long time the key or wait for the time out expiration 30 seconds about Attention the set values of temperature must respect the condition T1 T2 T3 In cooling mode T1 ...

Page 34: ...hort time the key To exit and go back to the normal operation automatic manual press for a long time the key or wait for the time out expiration 30 seconds about If a timing is active the display shows the symbol To interrupt a timing access again the menu and set the value Timing setting This menu allows the setting of a timing on the current operating mode expressed in hours or days For further ...

Page 35: ...u if remote control enabled minimum maximum settable temperature password for keylock system operation hours To access the menu ADV 1 From the normal operation display press for a long time the key until the symbol starts flashing on field 2 2 Press briefly the key until the symbol starts flashing and press the key to access the parameters modification 3 At this point the first parameter of the menu sta...

Page 36: ...ther information about the operating mode see the chapter Regulation type on page 44 Regulation type for heating mode only For heating mode it s possible to choose between on off regulation 5HJ or proportional U J 3 For further information about regulation type see the chapter Regulation type on page 44 For further information about regulation type see the chapter Regulation type on page 44 ...

Page 37: ...ostat is switched off It s possible to choose a value between 1 C and 50 C It s also possible to deactivate the antifreeze function by pressing the key until the display shows B In this case if the chronothermostat is switched off no safety temperature is maintained Adjustment of the measured temperature In particular installation conditions it can happen that the temperature measured by the devic...

Page 38: ... the strength of the signal between the device and the access point For values above 60dB excellent signal quality between 60dB and 90dB good signal quality below 90dB poor signal quality that could compromise the communication between the device and the access point In this case move the device closer to the access point This screen also shows the status of the Wi Fi connection steady on device c...

Page 39: ...ages in the example 42 F5 20 1E F8 20 Minimum Maximum settable temperature Under particular installation conditions for example in public buildings hotels etc it may be useful to limit the range of values that the temperatures T1 T2 T3 and Tm can assume in order to prevent incorrect settings by the user is the lower limit Allowed values 2 C NL Factory value 2 C NL is the upper limit Allowed values...

Page 40: ...key until the flashing dashes appear enter the password to unlock the keyboard which will remain unlocked for 30 seconds from the last press Note if the password has been forgotten to unlock the device it is necessary to remove and restore power to the device When switched on again the keyboard remains unlocked for 30 seconds which is sufficient time to access the appropriate menu and consult deacti...

Page 41: ... from automatic operation to manual operation 1 Press the key twice In the field 8 the setpoint Tm currently set flashes 2 set the desired setpoint with the keys and and confirm with the key 3 at this point on field 8 the value of the environment temperature reappears and the instrument operates in manual If you want to change the setpoint Tm press the key and repeat the points 2 and 3 To go back to t...

Page 42: ...nd of the environment where the device is installed Toff can have values between 1 C and 50 C or it can be completely excluded in this last case the maintainance of minimum temperature is not guaranteed The default Toff is 6 C but it s possible to modify this value by accessing the ADV menu see Antifreeze temperature on page 35 To switch the device off press the key until the symbol is displayed fi...

Page 43: ... only when the programming menu is entered It s possible to turn off the backlighting by pressing the key for 3 seconds To reactivate the backlighting press the key for at least 3 seconds MINIMUM AND MAXIMUM VALUES It s possible to display the measured values of minimum and maximum temperature To display these values press the key maximum value NL or minimum value During the display it is possible...

Page 44: ...mmer winter time change is managed automatically by the device increasing by one hour if you switch from solar time to summer time and decreasing by one hour if you switch from summer time to winter time The device is factory configured to switch to daylight saving time on the last Sunday in March at 02 00 to return to solar time on the last Sunday in October at 03 00 in accordance with what happen...

Page 45: ... week of the month first second third fourth last iii the month 1 12 iv the hour 3s 5 Press the key the current setting for the passage to the winter time is displayed indicated with the symbol In the example a the Sunday of the last week of October at 3 o clock b if it s necessary change the parameters with the keys and and move to the next parameter with the key The sequence requires the insertio...

Page 46: ... to the reaching of the setpoint Proportional regulation heating only In heating mode the on off regulation is available and also the proportional regulation which in some systems allows a more precise regulation to obtain a constant temperature This regulation requires to specify two parameters the band which represents the temperature values within whom to perform the proportional regulation The...

Page 47: ...or low thermal inertia systems fan coil 20 for medium thermal inertia systems aluminium radiators 30 for high thermal inertia systems cast iron radiators Select the regulation band value as follows broad band 5 C for systems with high thermal gradient narrow band 0 5 C for systems with low thermal gradient Attention the device is default configured to operate in on off with differential set at 0 3 ...

Page 48: ...thermostat changes the operating mode as described below The timed operations are the following Timed automatic If you set a timing in automatic status this off status will be maintained until the end of the timing will then switched to off mode Timed manual If you set a timing in manual status this off status will be maintained until the end of the timing operation will then switched to automatic...

Page 49: ...is calculated in minutes and for this reason if for example you set a timing of 3 days at 12 15 on Tuesday it will expire at 12 15 on Friday Attention the timings can end before their programmed expiration if one of these actions occur time date modification modification of the summer time change included manual modification of the operating mode change of the operating logic from winter to summer or...

Page 50: ...Q Q Q Q Q Q Q Q Q Q Q Q Q 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 P4 T3 Q Q Q Q Q Q Q Q Q Q Q T2 Q Q Q Q Q Q Q Q Q Q Q Q Q Q Q Q Q Q Q Q Q Q Q Q T1 Q Q Q Q Q Q Q Q Q Q Q Q Q Q Q Q Q Q Q Q Q Q Q Q 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 P5 T3 Q Q Q Q Q Q Q Q Q Q T2 Q Q Q Q Q Q Q Q Q Q Q Q Q Q Q Q Q Q Q Q Q Q Q Q T1 Q Q Q Q Q Q Q Q Q Q Q Q Q Q Q Q Q Q Q Q ...

Page 51: ...Q Q Q Q Q Q Q Q Q Q Q Q Q Q Q 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 P4 T3 Q Q Q Q Q Q Q Q Q Q Q Q Q T2 Q Q Q Q Q Q Q Q Q Q Q Q Q Q Q Q Q Q Q Q Q Q Q Q T1 Q Q Q Q Q Q Q Q Q Q Q Q Q Q Q Q Q Q Q Q Q Q Q Q 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 P5 T3 Q Q Q Q Q Q Q Q Q Q Q Q Q Q T2 Q Q Q Q Q Q Q Q Q Q Q Q Q Q Q Q Q Q Q Q Q Q Q Q T1 Q Q Q Q Q Q Q Q Q Q Q Q ...

Page 52: ... DECLARATION OF CONFORMITY Vemer declares that the device complies with the EU directive 2014 53 EU RED with reference to the following standards EN 60730 2 7 EN 60730 2 9 ETSI EN 300 328 ETSI EN 301 489 1 ETSI EN 301 489 17 The full text of the EU declaration of conformity is available on the Internet www vemer it Operationmode heating winter Regulationtype on off Differential on off 0 3 C Band p...

Page 53: ...ts working life The user must take the worn product to a sorted waste center or return it to the retailer when purchasing a new one Products for disposal can be consigned free of charge without any new purchase obligation to retailers with a sales area of at least 400 m2 if they measure less than 25 cm An efficient sorted waste collection for the environmentally friendly disposal of the used devic...