ROBOT HP7E / HP10E / HP12E / HP15E / HP20E
6. Graphical control
6-49
© VEMAG 2010
6.6.4.44 Maximum filling pressure (pressure monitoring on grinding system)
Display:
Max. filling pressure
Unit:
Bar [bar]
Resolution:
0.1 bar
Setting range:
Off / 10 – 50 bar (depending on the machine)
Application:
Separation grinder 982, separation attachment 801
• Enter max. filling pressure which, when reached, will cause the
machine to stop.
• Press
Enter
.
This function monitors pressure in separation grinder 982/ separation
attachment 801. Current pressure is displayed in bar. When the maximum
pressure entered is reached, the machine is stopped. Pressure can be
reduced by reducing speed.
The pressure is monitored even if these settings are deactivated. In this
case, the monitoring refers to the maximum value set in the machine
configuration settings.
Warning!
The machine stopping can be an indication that blades and hole plates
are blocked with sinew. In this case, clean the blade set.
6.6.4.45 Maximum temperature (temperature monitoring for the grinding system)
Display:
Temperature
Unit:
Degrees [°C] / Kilogram [kg]
Resolution:
0.1 °C / 1 kg
Setting range:
Off / -19.9 °C – +31.0 °C / 1,0 kg - 99 kg
Application:
Separation grinder 982, separation attachment 801
• Enter the max. temperature, at which to sound the alarm.
• Enter the min. temperature to define a temperature range you wish to
monitor.
• Enter the filling volume still to be reached after the alarm is sounded
before the machine stops.
• Press Enter.
This function monitors temperature in separation grinder 982/ separation
attachment 801. Current temperature is displayed in degrees Celsius.
If the temperature is outside the defined range, a message is issued
and the relevant indicator comes on.
Summary of Contents for ROBOT HP7E
Page 8: ......
Page 10: ...ROBOT HP7E HP10E HP12E HP15E HP20E 0 Foreword 0 2 VEMAG 2010...
Page 22: ...ROBOT HP7E HP10E HP12E HP15E HP20E 2 Description 2 8 VEMAG 2010...
Page 32: ...ROBOT HP7E HP10E HP12E HP15E HP20E 3 Installation and commissioning 3 10 VEMAG 2010...
Page 58: ...ROBOT HP7E HP10E HP12E HP15E HP20E 6 Graphical control 6 12 VEMAG 2010 USB stick plugged in...
Page 60: ...ROBOT HP7E HP10E HP12E HP15E HP20E 6 Graphical control 6 14 VEMAG 2010 Mode group Mode View...
Page 64: ...ROBOT HP7E HP10E HP12E HP15E HP20E 6 Graphical control 6 18 VEMAG 2010...
Page 66: ...ROBOT HP7E HP10E HP12E HP15E HP20E 6 Graphical control 6 20 VEMAG 2010...
Page 68: ...ROBOT HP7E HP10E HP12E HP15E HP20E 6 Graphical control 6 22 VEMAG 2010...
Page 100: ...ROBOT HP7E HP10E HP12E HP15E HP20E 6 Graphical control 6 54 VEMAG 2010...
Page 102: ...ROBOT HP7E HP10E HP12E HP15E HP20E 6 Graphical control 6 56 VEMAG 2010...
Page 112: ...ROBOT HP7E HP10E HP12E HP15E HP20E 6 Graphical control 6 66 VEMAG 2010...
Page 128: ...ROBOT HP7E HP10E HP12E HP15E HP20E 7 Cleaning 7 16 VEMAG 2010...
Page 164: ...ROBOT HP7E HP10E HP12E HP15E HP20E 10 Appendix 10 12 VEMAG 2010 10 8 Hydraulic plan...
Page 168: ...ROBOT HP7E HP10E HP12E HP15E HP20E 10 Appendix 10 16 VEMAG 2010...