EC-Declaration of Conformity
Note: This Declaration of Conformity and the
-mark affixed to the nameplate are valid for the vacuum pump within the Busch-scope of delivery.
When this vacuum pump is integrated into a superordinate machinery the manufacturer of the superordinate machinery (this can be the operating
company, too) must conduct the conformity assessment process acc. to the Directive Machinery 2006/42/EC for the superordinate machine, issue
the Declaration of Conformity for it and affix the
-mark.
We
Busch Produktions GmbH
Schauinslandstr. 1
79689 Maulburg
Germany
declare that vacuum pumps KC 0040 D VEMAG
in accordance with the European Directives:
–
“Machinery” 2006/42/EC,
–
“Electrical Equipment Designed for Use within Certain Voltage Limits” (so called “Low Voltage”) 2006/95/EC,
–
“Electromagnetic Compatibility” 2004/108/EC,
have been designed and manufactured to the following specifications:
Standard
Title of the Standard
Harmonised Standards
EN ISO 12100-1
EN ISO 12100-2
Safety of machinery - Basic concepts, general principles of design - Part 1 and 2
EN ISO 13857
Safety of machinery - Safety distances to prevent hazard zones being reached by the upper and lower limbs
EN 1012-1
EN 1012-2
Compressors and vacuum pumps - Safety requirements - Part 1 and 2
EN ISO 2151
Acoustics - Noise test code for compressors and vacuum pumps - Engineering method (grade 2)
EN 60204-1
Safety of machinery - Electrical equipment of machines - Part 1: General requirements
EN 61000-6-1
EN 61000-6-2
Electromagnetic compatibility (EMC) - Generic immunity standards
EN 61000-6-3
EN 61000-6-4
Electromagnetic compatibility (EMC) - Generic emission standards
Manufacturer
Person authorised to compile
the technical file
Dr.-Ing. Karl Busch
General director
Andrej Riwe
Technical writer
Troubleshooting
WARNING
_ab
Risk of electrical shock, risk of damage to equipment.
Electrical installation work must only be executed by qualified personnel that knows and observes the following regulations:
- IEC 364 or CENELEC HD 384 or DIN VDE 0100, respectively,
- IEC-Report 664 or DIN VDE 0110,
- BGV A2 (VBG 4) or equivalent national accident prevention regulation.
CAUTION
_ac
During operation the surface of the vacuum pump may reach temperatures of more than 70 °C.
Risk of burns!
Let the vacuum pump cool down prior to a required contact or wear heat protection gloves.
KC 0040 D VEMAG
Troubleshooting
0870149117 / 100111
page 3
Summary of Contents for ROBOT HP7E
Page 8: ......
Page 10: ...ROBOT HP7E HP10E HP12E HP15E HP20E 0 Foreword 0 2 VEMAG 2010...
Page 22: ...ROBOT HP7E HP10E HP12E HP15E HP20E 2 Description 2 8 VEMAG 2010...
Page 32: ...ROBOT HP7E HP10E HP12E HP15E HP20E 3 Installation and commissioning 3 10 VEMAG 2010...
Page 58: ...ROBOT HP7E HP10E HP12E HP15E HP20E 6 Graphical control 6 12 VEMAG 2010 USB stick plugged in...
Page 60: ...ROBOT HP7E HP10E HP12E HP15E HP20E 6 Graphical control 6 14 VEMAG 2010 Mode group Mode View...
Page 64: ...ROBOT HP7E HP10E HP12E HP15E HP20E 6 Graphical control 6 18 VEMAG 2010...
Page 66: ...ROBOT HP7E HP10E HP12E HP15E HP20E 6 Graphical control 6 20 VEMAG 2010...
Page 68: ...ROBOT HP7E HP10E HP12E HP15E HP20E 6 Graphical control 6 22 VEMAG 2010...
Page 100: ...ROBOT HP7E HP10E HP12E HP15E HP20E 6 Graphical control 6 54 VEMAG 2010...
Page 102: ...ROBOT HP7E HP10E HP12E HP15E HP20E 6 Graphical control 6 56 VEMAG 2010...
Page 112: ...ROBOT HP7E HP10E HP12E HP15E HP20E 6 Graphical control 6 66 VEMAG 2010...
Page 128: ...ROBOT HP7E HP10E HP12E HP15E HP20E 7 Cleaning 7 16 VEMAG 2010...
Page 164: ...ROBOT HP7E HP10E HP12E HP15E HP20E 10 Appendix 10 12 VEMAG 2010 10 8 Hydraulic plan...
Page 168: ...ROBOT HP7E HP10E HP12E HP15E HP20E 10 Appendix 10 16 VEMAG 2010...