7. Maintenance
7-7
ROBOT HP7C / HP10C / HP15C / HP17C
© VEMAG 2004
7.6.2 Vacuum pump (air filter and oil level)
An air filter is located in the intake line to the vacuum pump and this needs
to be cleaned weekly.
• Remove the housing cover next to the main switch on the rear of the
machine.
• Open the two locking clips (1) of the air filter and remove the filter
cover (2).
• Clean the filter cartridge (3) by blowing it out. If it is severely
contaminated, the filter cartridge must be replaced.
• Insert the filter cartridge and fix the filter cover in position.
1
Locking clips
2
Filter cover
3
Filter cartridge
Fig. 7-5
Air filter of intake line
2
3
1