background image

3

English: 

• Hand over these instructions to any new user.
• This product has been designed for use with genuine VELUX products. Use of 

the product in ways other than the ones shown in these instructions may cause 
damage or malfunction.

• If installed and used correctly, the interface WLF 111 normally requires a min-

imal amount of maintenance only.

• Disconnect from mains supply before carrying out any maintenance (including 

cleaning of window pane) or service work and ensure that it cannot be recon-

nected unintentionally during this time.

• The packaging can be disposed of with usual household waste.
• The interface WLF 111 complies with the EMC requirements for use in house-

hold and light industry environments.

• If you have any technical questions, please contact VELUX, see telephone list.

Deutsch:

• Die Anleitung an den jeweiligen neuen Benutzer weitergeben.
• Dieses Produkt ist für den Gebrauch mit original VELUX Produkten konstruiert. 

Der Gebrauch des Produkts in anderer als der in dieser Anleitung abgebildeten

Weise kann Schäden oder Funktionsstörungen verursachen.

• Bei richtiger Montage und Bedienung ist das Interface WLF 111 fast wartungs-

frei. 

• Bei Wartung (einschließlich Putzen der Fensterscheibe) und Service des Fen-

sters/Zubehörs zuerst die Netzspannung ausschalten und sicherstellen, dass 

diese nicht unabsichtlich wieder eingeschaltet werden kann.

• Die Verpackung kann mit dem Hausmüll entsorgt werden.
• Das Interface WLF 111 wird den Anforderungen der EMV-Richtlinie bei Anwen-

dung im Haushalt und im Kleingewerbe gerecht.

• Bei eventuellen technischen Fragen wenden Sie sich bitte an VELUX, siehe Tele-

fonliste.

Français :

• Veuillez remettre ces instructions à tout nouvel utilisateur.
• Ce produit a été conçu pour fonctionner avec des produits de marque VELUX.

Toute utilisation du produit différente de celles décrites dans la présente notice

peut provoquer des dommages ou entraîner un dysfonctionnement.

• Installée et utilisée correctement, l’interface WLF 111 ne requiert qu’un mini-

mum d’entretien.

• Avant toute vérification ou entretien de la fenêtre ou de ses accessoires (dont 

nettoyage du vitrage), débrancher l’alimentation. S’assurer que l’on ne puisse
pas rebrancher l’alimentation par inadvertance.

• L’emballage peut être jeté aux ordures ménagères.
• L’interface WLF 111 est conforme aux spécifications CEM pour une utilisation 

en logement et environnement industriel léger.

• En cas de questions techniques complémentaires, contacter VELUX au numéro

indiqué.

Dansk:

• Videregiv vejledningen til en evt. ny bruger.
• Dette produkt er konstrueret til brug sammen med originale VELUX produkter. 

Brug af produktet på andre måder end de i vejledningen viste kan medføre 
skader eller funktionssvigt.

• Ved korrekt montering og brug kræver interface WLF 111 normalt kun minimal

vedligeholdelse.

• Ved vedligeholdelse inkl. pudsning af vindue og service af vindue/tilbehør skal

netspændingen være afbrudt, og det skal sikres, at den ikke uforvarende kan 

genindkobles.

• Emballagen kan bortskaffes sammen med almindeligt husholdningsaffald.
• Interface WLF 111 overholder EMC-kravene til anvendelse i husholdnings- og 

let industrimiljø.

• Eventuelle tekniske spørgsmål rettes til VELUX, se telefonliste.

English: Important information
Deutsch: Wichtige Informationen
Français : Information importante
Dansk: Vigtig information

WLF 111 

451191

VELUX, DK-2950 Vedbæk

English: 

Instructions for interface WLF 111

Read installation instructions carefully before proceeding and
keep for future reference.

Deutsch:

Anleitung für Interface WLF 111

Vor Montagebeginn bitte sorgfältig die gesamte Einbauanleitung
lesen und für spätere Verwendung aufbewahren.

Français :

Notice de l’interface WLF 111

Lire attentivement la totalité de la notice avant l’installation, et la
conserver pour une utilisation ultérieure.

Dansk:

Vejledning for interface WLF 111

Læs hele vejledningen grundigt igennem før montering. Vejled-
ningen bør opbevares til senere brug.

English: Contents
Deutsch: Inhalt
Français : Sommaire
Dansk: Indhold

2

Choice of functions in interface WLF 111.....................4-5 
Wahl zwischen den beiden Funktionen im 

Interface WLF 111......................................................4-5
Choix entre les deux fonctions de l’interface WLF 111.... 4-5
Valg mellem de to funktioner i interface WLF 111..........4-5

Fitting of interface WLF 111...................................6
Montage des Interface WLF 111............................ 6
Fixation de l’interface WLF 111..............................6
Montering af interface WLF 111.............................6

Important information.............................................3
Wichtige Informationen..........................................3
Information importante............................................3
Vigtig information..................................................3

Connection of interface WLF 111.........................7-8
Anschluss des Interface WLF 111.........................7-8
Connexion de l’interface WLF 111.......................7-8
Tilslutning af interface WLF 111...........................7-8

Ventilation....................................................... 9-14
Lüftung.............................................................9-14
Aération...........................................................9-14
Ventilation........................................................9-14

Connection diagram........................................17-18
Schaltbild.......................................................17-18
Schéma de branchement..................................17-18
Diagram.........................................................17-18

S

M

Wiring for GGL/GGU INTEGRA............................19-20
Leitungsfürung für GGL/GGU INTEGRA..................19-20
Câblage pour GGL/GGU INTEGRA ......................19-20
Ledningsføring for GGL/GGU INTEGRA..................19-20

Individual control of sunscreening and ventilation.....15-16
Individuelle Steuerung von Sonnenschutz und 

Fenstermotoren.......................................................15-16
Contrôle individuel des moteurs de fenêtres, volets 

roulants et stores.....................................................15-16
Individuel styring af solafskærmning og ventilation...15-16

TM

TM

TM

TM

Summary of Contents for WLF 111

Page 1: ...egiv vejledningen til en evt ny bruger Dette produkt er konstrueret til brug sammen med originale VELUX produkter Brug af produktet p andre m der end de i vejledningen viste kan medf re skader eller f...

Page 2: ...ht unterst tzt Fran ais A l aide de la molette de r glage il est possible de choisir entre deux fonctions A ration automatique par contr le des moteurs de fen tres Le signal de commande est r p t chaq...

Page 3: ...is Exemple de connexion de l interface WLF 111 dif f rents produits lectriques VELUX fen tres et centrale de com mande Nota Certaines r f rences peuvent ne pas tre disponibles dans votre pays En cas d...

Page 4: ...ndarder EN 55014 1 EN 55014 2 N r ovenst ende interface tilsluttes en VELUX styreenhed en VELUX vindues bner eller en anden VELUX motor der er installeret i et VELUX ovenlysvindue betragtes det samled...

Page 5: ...re en anden som f eks en termostat i at bne vinduet p bestemte tidspunkter f eks n r bygningen er tom Signaler til styreindgangene bner eller lukker vinduerne helt til endeposition Med styreenhed WLC...

Page 6: ...nale auf Seite 17 18 Fran ais Lorsque la molette est cod e sur l interface WLF 111 contr le les diff rentes sorties moteurs ind pendamment les unes des autres L entr e 1 commande le moteur d ouverture...

Page 7: ...he Abbildung A Die Hilfsspannung er brigt sich dann Fran ais Dans les cas o les actionneurs sont des appareillages contacts secs libres de potentiel la tension sur l entr e doit provenir de la source...

Page 8: ...r anschlie en Dann das Loch im Blendrahmen versiegeln Aufputzleitungsf hrung B Eine der vorgestanzten Stellen am IR Empf nger siehe Abb B herausbrechen Die Leitung an die Anschl sse INT EXT anschlie e...