background image

 

WS1060 

V. 02 – 26/04/2013 

©Velleman nv 

 

set includes:  

o

 

receiver 

o

 

4 outdoor sensors: thermo-hygrometer, wind speed sensor, wind direction sensor, and rain sensor. 

5.

 

Overview 

Refer to the illustrations on page 

2-3

 of this manual. 

Base station display 

Time alarm enabled 

15 

Rainfall unit: mm or inch 

RCC signal reception 

16 

Outdoor temperature alarm high/low enabled 

Day of the week 

17 

Outdoor temperature 

Date 

18 

Outdoor signal reception 

Wind direction alarm enabled 

19 

Outdoor humidity 

Maximum measurements are displayed 

20 

Outdoor transmitter battery low 

Wind direction 

21 

Outdoor humidity alarm high/low enabled 

Minimum measurements are displayed 

22 

Rainfall 

Rainfall high alarm enabled 

23 

Rainfall period: 1h, 24h, week, month, or total 

10 

Indoor temperature alarm high/low enabled 

24 

Wind speed 

11 

Temperature unit: °C or °F 

25 

Wind speed unit: bft, mph, knots, km/h, m/s 

12 

Indoor temperature 

26 

Wind speed high alarm enabled 

13 

Indoor humidity alarm high/low enabled 

27 

Time 

14 

Indoor humidity 

 

 

Outdoor unit 

Wind direction sensor 

Thermo-hygrometer (shielded) and transmitter unit 

Bubble level 

Shaft 

Rain collector 

Anemometer 

6.

 

Installation 

Refer to the illustrations on page 

2-3

 of this manual. 

6.1

 

Assembly 

The thermo-hygrometer, rain collector, and wind direction sensor are already mounted on the shaft. You just 
need to attach the wind cups for the anemometer. 

1.

 

Push the wind cups onto the anemometer’s steel shaft 

[K]

2.

 

Use an Allen key (incl.) to tighten the screw on the side of the wind cups 

[L]

3.

 

Spin the wind cups and make sure they can move freely. If the movement is hindered, the wind speed 
measurements will be incorrect. 

6.2

 

Initialising the weather station 

Before installing the weather station in its final location, you must install batteries in the outdoor unit and base 
station, and let the devices initialise and synchronise. This makes sure that the communication between 
outdoor unit and base station is working correctly. Poor communication can often be improved by changing the 
location. 

Battery guidelines 

 

Do not puncture batteries or throw them in fire as they may explode. Do not attempt to recharge non-
rechargeable batteries (alkaline). Dispose of batteries in accordance with local regulations. Keep 
batteries away from children. 

 

Use only batteries of the correct size and voltage. 

 

Remove the batteries from the indoor and outdoor units if the device will not be used for a long time. Old 
batteries can begin to leak and damage the device. 

 

Respect the polarity when inserting batteries. The wrong polarity can damage the device. 

 

Alkaline batteries have a typical operating temperature range of -20°C~+54°C. Do not use the device 
outside this temperature range. 

Summary of Contents for WS1060

Page 1: ...ETEOROL GICA INAL MBRICA CON RELOJ DCF Y SENSOR EXTERIOR DRAHTLOSE WETTERSTATION MIT DCF UHR UND AU ENSENSOR ESTA O METEOROL GICA SEM FIO REL GIO DCF SENSOR EXTERNO BEZPRZEWODOWA STACJA POGODOWA ZEGAR...

Page 2: ...WS1060 V 02 26 04 2013 2 Velleman nv Base station Basistation Station de base Estaci n de base Basisstation Outdoor unit Buitenstation Station ext rieure Unidad exterior Au enger t G H I J...

Page 3: ...WS1060 V 02 26 04 2013 3 Velleman nv M O P Q R S T...

Page 4: ...from shocks and abuse Avoid brute force when operating the device Familiarise yourself with the functions of the device before actually using it All modifications of the device are forbidden for safe...

Page 5: ...eter rain collector and wind direction sensor are already mounted on the shaft You just need to attach the wind cups for the anemometer 1 Push the wind cups onto the anemometer s steel shaft K 2 Use a...

Page 6: ...d reception is not possible the transmitter stops searching after 1 minute and returns to normal operating mode transmitting weather data to the base station The transmitter retries once every two hou...

Page 7: ...ease decrease in larger steps The setting procedure will end automatically after 30 seconds if you press no keys or you can exit the setting procedure at any time by pressing HISTORY 7 1 Quick display...

Page 8: ...4 Setting alarms You can program the base station to trigger an alarm at a specific time or for specific indoor or outdoor weather conditions When an alarm is triggered the alarm sounds for 120 second...

Page 9: ...door humidity Set the indoor humidity value 1 99 The alarm goes off when the indoor humidity is higher than the specified value Indoor temperature Set the indoor temperature value 9 9 C 60 C The alarm...

Page 10: ...d HISTORY for 8 seconds The station is now in calibration mode The wind factor digits on the display flash 2 Press SET to go to the next setting use the or MIN MAX keys to change the values 3 To exit...

Page 11: ...vidual tips of the bucket in the rain collector You can adjust the total rainfall in 0 3 mm steps The total rainfall measurement works as follows 1 The rain collector is calibrated at the factory so t...

Page 12: ...sensor unit and pull it gently off the shaft 3 Slide the new sensor unit on the shaft and fix it with the screw 4 Reconnect the data cable 5 On the edge of the wind direction sensor there are markers...

Page 13: ...ce with original accessories only Velleman nv cannot be held responsible in the event of damage or injury resulted from incorrect use of this device For more info concerning this product and the lates...

Page 14: ...scherm tegen stof en extreme temperaturen Bescherm tegen schokken Vermijd brute kracht tijdens de bediening Leer eerst de functies van het toestel kennen voor u het gaat gebruiken Om veiligheidsredene...

Page 15: ...stang C Regencollector F Anemometer 6 Installatie Raadpleeg de afbeeldingen op pagina 2 3 van deze handleiding 6 1 Montage De thermo hygrometer regen en windrichtingmeter zijn al gemonteerd op de met...

Page 16: ...len Bij het ontvangen van het DCF signaal knippert de led aan de achterzijde van de regencollector 5 keer en licht daarna gedurende 20 seconden op De zender stuurt de tijdsgegevens naar het basisstati...

Page 17: ...stelbare bevestigingsringen M 7 Het basisstation programmeren Het basisstation is voorzien van 5 toetsen voor een gemakkelijke bediening SET HISTORY ALARM en MIN MAX Druk op SET om door de instellinge...

Page 18: ...druk op HISTORY 7 3 Historiekmodus In historiekmodus worden metingen van de voorbije 24u weergegeven Historiek weergeven 1 In normale weergavemodus druk op HISTORY Het station is nu in historiekmodus...

Page 19: ...nelheid van een windstoot hoger is dan de ingestelde waarde Windrichting Stel de windrichting in Het alarm gaat af wanneer de wind komt van de ingestelde windrichting 1u neerslag Stel de waarde in van...

Page 20: ...mwaarden resetten Om een minimum of maximumwaarde te resetten 1 Ga in minimum en maximummodus en druk op om de waarde die u wilt resetten weer te geven 2 Houd SET ingedrukt gedurende 3 seconden 3 Herh...

Reviews: