Velleman MML10 Quick Start Manual Download Page 1

MML10 version 2                                                                                                                                                      GB 

MML10 – Message Board 

 
 

1. Features 

 
 
Your electronic message board is ideal for advertisements and meetings. You can programme 
up to four original messages and set the message board to repeatedly run a single message or 
run several messages in a programmed sequence. You can also connect the message board to 
your alarm system and programme a fifth message that only appears when an intruder triggers 
your alarm system. 
 

Additional features include : 

 
Adjustable scrolling speed  : controls the speed with which the message scrolls across the 

display. 

Memory backup 

: saves your messages for up to a year if the message board is not 

connected to an AC power source. 

 
Warning :  Do not use the message board in your vehicle. Using such a device in your vehicle 

endangers other motorists and constitutes a penal act is some countries. 

 
 

2. Installation 

 
 
You can place the message board on a horizontal surface or mount it on a wall. If you plan to 
connect the display to your alarm system, you should select a location where people can read 
the alarm messages, e.g. in front of a window. 
 
Caution : This message board is designed for indoor use only. Protect the device against water, 

moisture and excessive heat in order to ensure proper operation. 

 

Placing the message board on a table 

 
Place the message board on a stable and horizontal surface (e.g. a table). Use a screwdriver to 
loosen the screws at the back of the device if you wish to adjust the viewing angle of the 
message board. Retighten the screws afterwards. 
 
 
 
 
 
 
 
 
 

FIG. 1 

Summary of Contents for MML10

Page 1: ...AC power source Warning Do not use the message board in your vehicle Using such a device in your vehicle endangers other motorists and constitutes a penal act is some countries 2 Installation You can...

Page 2: ...8 150mm apart 3 Insert the supplied screws in the holes and let them protrude from the wall by 5 to 6mm 4 Fit the keyhole slots of the back plate over the screws and press the back plate against the w...

Page 3: ...adapter The outer ring of the plug should be connected to the negative pole The plug should be compatible with the message board s 9V jack Using an adapter that does not meet these specifications may...

Page 4: ...e supplied power cable to the ALARM jack on the side of the message board 2 Connect the cable s two wires to the N O normally open terminals of your alarm system These terminals should not supply powe...

Page 5: ...e device is able to resume its display of messages without having to perform the self test again The message board will no longer display messages if the display is deactivated The alarm message howev...

Page 6: ...Message 1 will be displayed Press Y if you wish to store a message The display will now read PROGRAM MESSAGE _ The cursor appears and you should now use the procedure outlined in 6 Type the Message se...

Page 7: ...de The original message will now continuously scroll across the screen The display will read WARNING THE MESSAGE IS EMPTY if a message does not contain at least one character In this case you should f...

Page 8: ...ss OFF END when the editing is finished The display now reads SAVE IT Y OR N Press Y to save the message The message will now continuously scroll across the display Press N to leave the edit mode The...

Page 9: ...ssage Use the procedure outlined under heading 8 Entering a Message on p 5 in order to enter an alarm message but press 5 for the message number Follow the procedure outlined under heading 9 Editing a...

Page 10: ...quential display mode Message 1 will appear and repeatedly scroll across the display when the message board or the display is reactivated Reading Messages in the Sequential Display Mode Press or to vi...

Reviews: