2) BASIC WIRINGS FOR DOOR LOCK OPEN AND ALARM ARM-DISARM CONTROL
NOTE:
The door lock function is exactly the same as like the Application Example (1)
Relay Output 2 is used for Alarm Arm-Disarm Control. Please consult your alarm control panel
manual for the appropriate output contact and the operation mode for the control; such as N.O.
or N.C. contact, and Momentary or Start / Stop mode are required.
Connect the Tamper Switch to a 24 hour N.C. zone and the Duress output to a 24 hour N.O. zone
for tamperproof and emergency reporting.
Connect the common ground to link up the keypad and the alarm control panel to achieve the
logical functions is necessary.
Please also see the NOTE stated in Application Example (1) for the common information.
●
●
●
●
●