CAMCOLD4_v2
VELLEMAN
5
5. Setting the Protocol and the Camera ID
Before installing the camera, configure the camera ID and the communication protocol using the DIP switches.
There are two sets of DIP switches. Note that the default protocol is
Pelco-D with a baud rate of 2400 bps.
a.
Protocol Setting
PRO0
Pin 1
PRO1
Pin 2
PRO2
Pin 3
Protocol / Baud
ZM1
Pin 4
ZM2
Pin 5
NT/PAL
Pin 6
Camera
OFF
OFF
OFF
Pelco-D, 2400 bps
OFF
OFF
OFF
SONY X18, NTSC
ON
OFF
ON
Pelco-D, 9600 bps
OFF
OFF
OFF
CNB X26, NTSC
OFF
ON
OFF
Pelco-P, 4800 bps
ON
OFF
OFF
CNB X22, NTSC
ON
ON
ON
Pelco-P, 9600 bps
ON
OFF
OFF
LG X27, NTSC
OFF
ON
ON
SONY X18, PAL
OFF
ON
ON
CNB X26, PAL
ON
ON
ON
CNB X22, PAL
ON
ON
ON
LG X27, PAL
Press F4 on the controller and select the same protocol as the one on the camera.
b.
Camera ID Setting
Make sure the camera ID on the DIP switches and the camera ID on the
controller are identical. When controlling more than one camera, it is
recommended to memorize the IDs and the location of each camera.
By changing the DIP switch setting, you can set the binary number for each
camera ID (1 ~ 63, except 0). Default camera ID is 1. Example: Set the
camera ID as 10: 0 + 2 + 0 + 8 + 0.
c.
RS485 Resistor
It is recommended to set the terminal resistor of the last camera in the series to ON. The switch is placed on the
alarm and connection board.
Summary of Contents for CAMCOLD4