![background image](http://html1.mh-extra.com/html/vela/argus-2000-1500/argus-2000-1500_developers-manual_3878168124.webp)
116
Argus Encoder Family Version 2.6 API Developer’s Guide
Filter Manager Error/Status Codes
-33, -34
Error resetting or starting audio storage
component.
Summary message. Check
log file for more specific
messages. Last encode
may not have shut down
correctly? Exit application
and try again.
-35
Video storage, Ligos storage, or plug-in compo-
nent failed to start.
Summary error. Check for
more specific error
messages in log.
-36
Main storage component failed to start or reset.
Summary message. Check
for more specific messages
in error log.
-39
Unable to set outpoint on tape deck.
Check COM port connection
(including converter). Make
sure tape deck is on remote.
Make sure application is
looking at the correct COM
port.
-41
Invalid VTR shuttle speed requested through
Sony protocol.
-42
Tape deck failed to receive shuttle command.
Check COM port connection
(including converter). Make
sure tape deck is on remote.
Make sure application is look-
ing at the correct COM port.
-44
Invalid pre-roll value. Pre-roll should be a num-
ber between 0 and 60 (seconds). AND mark-in
value must be greater than pre-roll.
Check validity of mark-in
and preroll.
-45
When you adjust the mark-in time code by add-
ing or subtracting the pre-roll adjustment, the
result is invalid (<0).
Check mark-in and adjust-
ment time codes. Adjust-
ment must be less than
mark-in.
-47
Unable to read preroll from tape deck.
Check COM port connec-
tions, Check to see that VTR
is in remote mode, etc.
Filter Manager Error/Status Codes (Continued)
Error Code
Meaning
Comments
Table C-1. Filter Manager Error/Status Codes (Continued)