124
Argus Encoder Family Version 2.6 API Developer’s Guide
Filter Manager Error/Status Codes
-254
An attempt to create a pin object failed. The error
message will indicate which pin.
Ascertain that Vela_Pin is
registered.
-255
Pin component failed when trying to create a
mutex
System error. Check handle
count using task manager.
-256
Pin writer not started.
Occurs only with a new
pause/resume.
-257
Pin method unsupported.
Occurs only with a new
pause/resume.
-258
Invalid pin read request.
-260
Undefined error occurred when attempting to
create or use a pin.
-331
RemoteStore component attempted to write very
last block of data to the file, but failed.
This error occurs only when the FilterMgr
“Optimized MuxWrite” flag is set to 1.
We use a write procedure
that requires that all write-
blocks must be evenly divis-
ible by the disk sector size.
To get around this restric-
tion on the last block of
data, we close the file,
reopen it in another mode,
then write the last block.
This error could be a timing
error-make certain that no
attempt was made to move
or lock the file before the
encode finished.
-332
Error closing the remote (FTP) file.
Make certain that the FTP
process was not aborted
before the encode finished.
-334
Failure creating, initializing, or using the decoder
input pin (usually from the Mux).
Filter Manager Error/Status Codes (Continued)
Error Code
Meaning
Comments
Table C-1. Filter Manager Error/Status Codes (Continued)