DIP Switch Setting
PTZ CAMERA
DIP S/W NO.
DEFINITION
DETAIL
1
Binary Number Protocol #1
321 : Dip S/W Number
000 : PELCO-D/P 001
: VICON
010 : SAMSUNG 011
: SAE
100 : x 101
: x
110 : x 111
: x
2
Binary Number Protocol #2
3
Binary Number Protocol #3
4
Binary Number Baud rate #1
54 : Dip S/W Number
00 : x 01
: 2400 bps
10 : 4800 bps
11 : 9600 bps
5
Binary Number Baud rate #2
6
Reserved
Reserved
7
Reserved
Reserved
8
Termination
RS-485 terminating resistance can be used
by user.
ON : Available
OFF : Not Available.
B. 485 TERMINATION
The 1st of DIP SW2 is used for
100Ω
termination.
Set ON DIP SW2 -1st of only the last looped camera from the controller.
Even in case of only one camera, set ON DIP SW2 -1st of the camera.
C. FUNCTION
CAM 1
CAM 2C
AM n-1
CAM n
TERMINATION
SW1-ON
037