VEGASON 51K … 53K
9
Survey
VEGASON …
51K
52K
53K
Signal output
– active (4 … 20 mA)
•
•
•
– passive (4 … 20 mA)
•
•
–
Voltage supply
– two-wire technology (voltage supply and
signal output via a two-wire line)
•
•
–
– four-wire technology (voltage supply separated
from the signal line)
•
•
•
Process connection
– G1
1
/
2
A; 1
1
/
2
“ NPT
•
–
–
– G 2 A; 2“ NPT
–
•
–
– DN 100 compression flange
–
–
•
Adjustment
– PC
•
•
•
– adjustment module in the sensor
•
•
•
– adjustment module in external indicating instrument
•
•
•
– HART
®
-handheld
•
•
•
Measuring range in m
– liquids
0,25 … 4
0,4 … 7
0,6 … 15
– solids
0,3 … 2
0,25…3,5
0,75 … 7
Types and versions
Type code
The second letter of the type designation e.g.
VEGASON 5[1]… differentiates the instru-
ments acc. to process connection and meas-
uring range.
The letter e.g. VEGASON 51[K] characterises
the output signal:
K stands for an analogue 4 … 20 mA output
signal (compact instrument).
VEGASON 51 K E X . X X
(example)
P - 90 … 250 V AC (only in USA)
N - 20 … 36 V DC, 24 V AC (only in USA)
Z - supply via signal conditioning instrument (only in USA)
U - only in USA
X - outside the USA
Ex approved
K - Analogue 4 … 20 mA output signal
(two-wire or four-wire technology)
V - Digital output signal (two-wire technology)
Type 51: Measuring range 0,25 … 4 m
Type 52: Measuring range 0,4 … 7 m
Type 53: Measuring range 0,6 … 15 m
Measuring principle (SON for ultrasonic)