17
4 Mounting
VEGAMIP R62 • Receiving unit
41911-EN-200522
Avoid long sockets in which the medium can remain and if possible,
mount VEGAMIP 62 front-flush. This applies mainly if buildup and
dust are expected.
2
1
Fig. 11: Front flush mounting
1 Unfavourable mounting - bulk solid can settle in front of the sensor
2 Correct front-flush mounting
If a front-flush mounting is not possible, you can fill long sockets with
a plastic or ceramic cylinder to avoid build up of bulk solids and dust
deposits. Select the material according to the diameter of the socket
and adapt the length as far as possible to the shape of the vessel wall.
Secure the filling material against falling out or turning. If using a fixing
screw is technically not possible, you can secure the material in the
socket with an adhesive.
Buildup