39089-US-210509
Mounting
Point Level
Mount the SHLG
®
parallel to the process pipe or vessel.
Figure 4.2
SHLG Point Level Orientation
Source Interference
When multiple adjacent pipes, vessels, or conveyors have nuclear gauges, you
must consider the orientation of the source beams so each gauge senses
radiation only from its appropriate source. Place the source holders on the inside,
with the radiation beams pointing away from each other.
Figure 4.3
Source/Detector Arrangement for Adjacent Vessels
1. Radiation Beam
2. Detector
3. Source Holders