7
4.2.2.
M1:
[Closing Profile]
The first 5 parameters are position references expressed as a percentage of the total length of the learned stroke.
Other parameters are speed references expressed as a percentage of the maximum value (rated RPM of the motor).
Sub-menus
Description
Int. Keyp.
DISP801
c0
[Point D_c]
Start of closing acceleration ramp (Default 98)
c1
[Point C_c]
End of closing acceleration ramp (Default 65)
c2
[Point B_c]
Start of closing deceleration ramp (Default 45)
c3
[Point A_c]
End of closing deceleration ramp (Default 05)
c4
[Point Z_c]
Start of acceleration for closure coupling (Default 02)
c5
[Speed v1_c]
Initial closing speed (Default 08)
c6
[Speed vH_c]
Maximum closing speed (Default 60)
c7
[Speed v2_c]
Final closing speed (Default 08)
c8
[Speed v_rif]
Synchronizing speed in closing
(Default 10)
OPEN DOOR (100 %)
CLOSED DOOR (0 %)
SPEED (%)
POSITION (%)
VH_c ( c6 )
V2_c ( c7 )
V1_c ( c5 )
A_c
( c3 )
B_c
( c2 )
C_c
( c1 )
D_c
( c0 )
Z_c
( c4 )