OTAA (Over The Air Activation)

 – meter makes three trying to connect the network with configured 

frequency plan (RU868 by default). The meter will begin to send data when it receives the LoRaWAN 
activation confirmation. If all attempts fail, the meter will continue to accumulate data and will 
attempt to connect to the network every six hours.

 

By default, meter makes attempts to connect to the network with OTAA method once a day until it 

connected to the server. You can change default settings via “Vega LoRaWAN Configurator” application (see 
part 3.5).

 

 

You can initiate emergency communication session including activation by a magnet getting on 

external magnetic field reception area for 15-20 seconds (fig.2).

 

 

2.6.2 CLASS 

А 

DEVICE

 

 

Meter is class A device (by LoRaWAN classification) and has the following features:

 

 

ADR («Adaptive Data Rate»);

 

 

sending of confirmed messages (configurable);

 

 

storing undelivered messages in device memory while sending messages with confirmation;

 

 

adjustable data collection and transmission periods;

 

 

temperature measurement;

 

 

charge measuring of the built-in battery in %.

 

 

2.6.3 COMMUNICATION AND COLLECTION PERIODS

 

 

2.6.3.1 COMMUNICATION PERIOD

 

 

Communication period may be equal to 1, 6, 12 and 24 hours. Device sends data in random point in 

time during set period

:

 

 

If communication period equal to 1 hour, then during the next hour;

 

 

If communication period equal to 6 hours, then during the next 6 hours;

 

 

If communication period equal to 12 hours, then during the next 12 hours;

 

 

If communication period equal to 24 hours, then during the next 24 hours.

 

 

2.6.3.2 DATA COLLECTION PERIOD

 

 

Data collection period may be equal to 1, 6, 12 and 24 hours. Meter saves data in the internal 

memory with time by the internal clock:

 

 

at 00.00 when the period is equal to 24 hours;

 

 

at 00.00 and at 12.00 when the period is equal to 12 hours;

 

 

at 00.00, 6.00, 12.00 and 18.00 when the period is equal to 6 hours;

 

 

at the beginning of current hour when the period is equal to 1 hour.

 

 

The readings are stored in the meter memory until the next  communication session; maximum 

number of saved messages is 200. At the next communication session, the device starts sending 
accumulated messages, from the earliest to the latest. 

 

 

With the "Confirmed uplinks" option turned off, the device just sends all accumulated messages to 

the network in order from the earliest to the latest. There is no check of package delivery in this mode. Non-
transmitted messages do not save in the device memory.

 

With the "Confirmed uplinks" option turned on, the device will send the next message only after 

receiving a confirmation of the delivery of the previous one. If such confirmation has not received after the 
fulfilled in the settings uplink number of transmissions, the meter completes the communication session 
until the next one according to the schedule. In this case, the device continues to collect data according to 
the data collection period and store it in memory. Non-transmitted messages remain in the device memory 
until the next communication session.

 

Summary of Contents for SGVE

Page 1: ...iotvega com betar ru Electronic Water Meter SHVE SGVE with LPWAN 868 VEGA radio channel the second generation1 User Manual 1 In production since December 2020...

Page 2: ...network 10 2 6 2 Class device 11 2 6 3 Communication and collection periods 11 2 6 3 1 Communication period 11 2 6 3 2 Data collection period 11 3 VEGA LORAWAN CONFIGURATOR APPLICATION 12 3 1 Operatin...

Page 3: ...COL 26 4 1 Transmitting messages 26 4 1 1 MODEM transmits packets with the following types 26 4 1 2 Time correction request 26 4 1 3 Packet with current settings 26 4 2 MODEM Recieves packets with the...

Page 4: ...terfaces configurator application and communication protocol and some other data which is necessary to meters exploitation This manual is targeted at specialists familiar with installation work fundam...

Page 5: ...xternal magnetic field influence electronic magnetic seal control of internal battery charge control of temperature inside device case reference Information registration of random reverse flow of wate...

Page 6: ...eter mm DN15 15 mm Ambient temperature 5 55 Relative humidity of ambient air 0 100 Ambient pressure range kPa 86 106 Temperature class 30 90 Maximum admissible pressure MAP10 Pressure loss p 63 Flow p...

Page 7: ...l Sensitivity dBm 138 Radio coverage in restrained urban conditions km Up to 5 Radio coverage within line of sight km Up to 15 Power Power source Internal Lithium Battery 3 6 V Battery size ER17505 or...

Page 8: ...nd rotated by water flowing The impeller turnovers number is proportionally to water flowing volume A bipolar magnet is molded into the impeller Counting Hall sensor takes information about the impell...

Page 9: ...um method of check sum calculation serial number of the meter in the S format for example S40488568 date of the meter verification in the Id dd mm yy format for example Id 01 01 20 2 2 METER S OPERATI...

Page 10: ...rong enough the meter LED indicator displays warning symbol b at the high order digit place first index but readings still displaying If the external magnetic field influence continues more than 5 min...

Page 11: ...ours If communication period equal to 12 hours then during the next 12 hours If communication period equal to 24 hours then during the next 24 hours 2 6 3 2 DATA COLLECTION PERIOD Data collection peri...

Page 12: ...TTENTION Full functionality becomes available after password entering You can see only DevEUI and no available any settings or other information without the password The Send Password command is place...

Page 13: ...UTER 3 3 1 ADAPTER CONNECTION DRIVER INSTALLING Meter has the optical port for connection to computer which also used for testing The adapter Optical port USB connected to the USB port of computer car...

Page 14: ...s of the license agreement then I accept and fig 5 The installation will begin after that Figure 5 Driver installing After finish of install process the window will appears fig 6 After pressing adapte...

Page 15: ...n in relation to meter_ General view Figure 8 Optical port USB adapter location in relation to meter_ Close up At the main window of the application you need to choose the device model Vega SHVE SGVE...

Page 16: ...16 Figure 10 Device info tab After making the necessary changes to the settings you should click the Apply settings button and only then disconnect from the device with the Disconnect button...

Page 17: ...fo tab displays network information about the device there are basic information Device info field current state Network info Link check keys for device activation in LoRaWAN network ABP info OTAA inf...

Page 18: ...are version and time in UTC 0 00 factory number and meter verification date ATTENTION The date of the meter verification does not correspond to the current 3 4 2 5 Network info shows whether the devic...

Page 19: ...19 Figure 13 Link check field 3 4 2 8 Device output not displayed in the Simple mode monitoring the device status displaying all events in real time...

Page 20: ...ncy plans specified in table 3 Table 3 Frequency plan2 Channel Frequency Modulation EU868 1 868 1 MultiSF 125 kHz 2 868 3 MultiSF 125 kHz 3 868 5 MultiSF 125 kHz RX2 869 525 SF12 125 kHz RU868 1 868 9...

Page 21: ...econd receiving window parameters are mandatory Without these parameters the custom frequency band will be considered empty 3 5 2 2 Activation type allows setting up ABP or OTAA device activation meth...

Page 22: ...n accept delay 1 not displayed in the Simple mode sets the time that the device will open the first receiving window to receive confirmation for the join request from the LoRaWAN network fig 19 The se...

Page 23: ...ower not displayed in the Simple mode the device RF transmitter power has adjusted to this value when sending packets to the LoRaWAN network fig 21 This option can be change by the network server Figu...

Page 24: ...meters of the device temperature battery charge meter diameter current readings 3 6 2 2 Data transmission settings a group of parameters that allows you to configure the collection and transmission pe...

Page 25: ...are shown Table 4 Parameter Value Communication period 12 hours Data collection period 12 hours Time zone UTC 03 00 Frequency plan RU868 Activation method OTAA Confirmed Uplinks function OFF Adaptive...

Page 26: ...byte Leak flag continuous consumption 0 3 cubic meter per 30 minutes 1 leak 0 normal uint8 1 byte Breakthrough flag continuous consumption 0 3 cubic meter per 30 minutes 1 breakthrough 0 normal uint8...

Page 27: ...Table 8 Size in bytes Field description Data type 1 byte Packet type this packet 1 uint8 4 2 2 PACKET WITH SETTINGS Received on LoRaWAN port 3 The configuration package is completely identical to the...

Page 28: ...ommunication period 1 byte 1 1 hour 2 6 hours 3 12 hours 4 24 hours 49 Data collection period 1 byte 1 1 hour 2 6 hours 3 12 hours 4 24 hours 55 Timezone in minutes 2 bytes from 720 to 840 4 2 3 UNLOC...

Reviews: