QUICK START GUIDE: RTU-300/320/600

 

 

 

VeEX Inc. 2827 Lakeview Court, Fremont, CA  94538  USA  Tel: +1.510.651.0500  Fax: +1.510.651.0505               

www.veexinc.com

     

[email protected]

  

How to Configure the RTU-300/320/600

 

Testing with the RTU (Remote Test Unit) 

 

Introduction 

The  RTU-300/320/600  is  a  rack  mounted  1G-100G  Ethernet  test  head  for  performance  testing  and  monitoring 
Carrier Ethernet and broadband networks. The main application of the RTU-300/320/600 is to be used under the 
VeSion

  performance  testing  and  monitoring  platform,  where  several  RTU-300/320/600  can  be  added  and 

operated for service provisioning, service activation testing, and service assurance applications.  
 
Optionally the RTU-300/320/600 can be operated as a stand alone test device through VNC/web remote access. In 
this  standalone  mode,  users  have  access  to  other  interfaces  and  features  that  are  available  such  as  OTN, 
SONET/SDH, and Fibre Channel. 
 

64K-100GE

 test rates are supported on the same module. These factory-installed hardware options allow flexibility 

to fit any additional application at a later time. For example, the addition of a second RTU-320 or RTU-600 module  
can be installed concurrently on the same test platform.   
 
RTU-320 Test Ports: 
2 x SFP+ for Ethernet, OTN & SONET/SDH 
2 x RJ45 for Ethernet 
2 x BNC for E1/DS3 
1 x RJ45 for E1/DS1 
1 x SMA for Clock Source 
 
RTU-600 Test Ports: 
1 x QSFP28 for 100GE and OTU4  
1 x QSFP+ for 40GE, OTU3  
1 x External Clock Interface 

 

Space efficient 1U rackmount with built-in, dual power switching matrix ensures continuous operation if the main 
power supply fails. 
 

 

 
 
 
 

Summary of Contents for RTU-300

Page 1: ...urt Fremont CA 94538 USA Tel 1 510 651 0500 Fax 1 510 651 0505 www veexinc com QUICK START GUIDE How to Configure the RTU Remote Connection Software Upgrade Port Configuration RTU 300 320 600 June 202...

Page 2: ...in this document may or may not be available in your test equipment or may look slightly different Make sure it is updated to the latest software packages available and that is has any related license...

Page 3: ...U 300 320 600 can be operated as a stand alone test device through VNC web remote access In this standalone mode users have access to other interfaces and features that are available such as OTN SONET...

Page 4: ...it is a known IP address to the user If the IP address is unknown the serial port must be used to assign verify an IP address Connect via VNC or VeSion to configure the unit and run tests 1 Download t...

Page 5: ...l 1 510 651 0500 Fax 1 510 651 0505 www veexinc com CustomerCare veexinc com 5 Note If you are using Putty for example use the following settings to connect to the RTU 115200 baud rate 3 The Status wi...

Page 6: ...ll be populated after the serial number is entered The VeSion server IP address Probe Server IP must be assigned in order to use VeSion to log in to the unit and launch tests The Local IP address shou...

Page 7: ...obe Configuration Tool To configure RTU operating mode follow these steps 1 Use the RTU 320 section to select RTU 300 320 Operation Mode VeSion Operate via VeSion management tool SCPI Operate via web...

Page 8: ...nc com 8 Web Remote Access Menu VNC Standalone Mode In order to operate the RTU 300 320 600 launch a new web browser window and type the RTU 300 320 600 management IP address Login using appropriate c...

Page 9: ...rade Perform a platform upgrade Module Upgrade Perform a module upgrade RTU 300 320 600 System Settings and Operating Mode Configuration via Web Remote Access VNC Standalone Mode To configure RTU oper...

Page 10: ...he Web Remote Access option and perform the following steps from the Platform Upgrade tab 1 Download and unzip the required software from https www veexinc com en us Support Software Make sure to ente...

Page 11: ...ce the upload process is completed and file verification is successful click Upgrade 6 Users will be asked to confirm if the upgrade procedure should continue as a reboot will be performed at the end...

Page 12: ...he following steps from the Module Upgrade tab 1 Download and unzip the required software from https www veexinc com en us Support Software Make sure to enter the RTU 300 320 600 serial number to find...

Page 13: ...pe the IP address configured previously after launching the VNC app The default password is pass1 To start testing load the required test application using the New button in Port Group 1 or Port Group...

Page 14: ...ss This section will focus on creating new users and assigning credentials to tester types in VeSion a web based management tool 1 Launch your web browser and type the VeSion server IP address Type yo...

Page 15: ...505 www veexinc com CustomerCare veexinc com 15 4 Tester level credentials enable users to run tests Privileges are limited to running tests and viewing configurations only 5 Notice the difference bet...

Page 16: ...s only Click on Add New Select Tester from the Group drop down menu Input the Name User ID and Password and click Save To test the newly created user log out and log back in using these new credential...

Page 17: ...Sion server Select a module Slot as shown below and a Test Mode The following test modes are available 1GE Dual Port L2 L3 Testing Enables running the 1GE Loopback Throughput V SAM and RFC2544 tests o...

Page 18: ...ting Enables running 10GE Loopback Throughput V SAM and RFC2544 tests on one port and 1GE V PERF test on another 1GE 10GE Dual Port L2 L3 Testing Enables running 1GE Loopback Throughput V SAM and RFC2...

Page 19: ...1 510 651 0505 www veexinc com CustomerCare veexinc com 19 Click on the Network Status tab to verify that the IP Configuration status is OK It should say PASS for IP Gateway Running a Throughput Test...

Page 20: ...ut Test via VeSion follow the next steps 1 From the home page click On Demand Test 2 Make sure the right RTU 300 is selected if other devices are also being used by this VeSion server Select the test...

Page 21: ...om CustomerCare veexinc com 21 4 Configure the Header Traffic General and other parameters and click Save Use the Save as New to save this profile for future testing Use a relevant name to easily sele...

Page 22: ...Test via VeSion 1 Select V SAM from the Test Type drop down menu 2 Once all the General and Service parameters are set save the profile for future use by clicking on Save as New Use a relevant name to...

Page 23: ...Test via VeSion To start the V PERF Test via VeSion 1 Make sure that the selected port is configured for L4 Testing and select V PERF as a Test Type in the drop down menu 2 Set the mode to be Server...

Page 24: ..._____________________________________________________________________ ___________________________________________________________________________________________ ______________________________________...

Reviews: