Serial Interface Manual
•
TLS2 Monitoring Systems
Part No. 577013-767, Revision H
28
Function Code:
204
Version 1
Function Type:
In-Tank Shift Inventory Report
Command Format:
Display:
<SOH>I204TT
Computer:
<SOH>i204TT
Typical Response Message, Display Format:
<SOH>
I20401
22-05-01 14:56
STATION HEADER 1....
STATION HEADER 2....
STATION HEADER 3....
STATION HEADER 4....
SHIFT REPORT
TANK PRODUCT
1 REGULAR UNLEADED VOLUME TC VOLUME ULLAGE HEIGHT WATER TEMP
SHIFT 1 STARTING VALUES 8518 8492 1482 76.26 0.00 64.57
ENDING VALUES 8518 8492 1482 76.26 0.00 64.57
DELIVERY VALUE 0
TOTALS 0
<ETX>
Typical Response Message, Computer Format:
<SOH>i204TTYYMMDDHHmmTTpssNNFFFFFFFF...
TTpssNNFFFFFFFF...&&CCCC<ETX>
Notes:
1.
YYMMDDHHmm - Current Date and Time
2.
TT - Tank Number (Decimal, 00 = all)
3.
p - Product Code (single ASCII character, from 20 Hex - 7E Hex)
4.
ss - Shift Number 01, 02, 03
5.
NN - Number of eight character Data Fields to follow (Hex)
6.
FFFFFFFF - ASCII Hex IEEE float:
1. Start Volume
2. Start Ullage
3. Start TC Volume
4. Start Height
5. Start Water
6. Start Temperature
7. End Volume
8. End Ullage
9. End TC Volume
A. End Height
B. End Water
C. End Temperature
D. Total Value
7.
&& - Data Termination Flag
8.
CCCC - Message Checksum