background image

Notice

Veeder-Root makes no warranty of any kind with regard to this publication, including, but not limited to, the implied warranties of

 

merchantability and fitness for a particular purpose.

Veeder-Root shall not be liable for errors contained herein or for incidental or consequential damages

 

in connection with the furnishing, performance, or use of this publication.

Veeder-Root reserves the right to change system options or features, or the information contained in this publication.
This publication contains proprietary information which is protected by copyright. All rights reserved. No part of this publication

 

may be photocopied, reproduced, or translated to another language without the prior written consent of Veeder-Root.
Contact Red Jacket Technical Support for additional troubleshooting information at 800-323-1799.

DAMAGE GOODS/LOST EQUIPMENT

Thoroughly  examine all components and units  as  soon  as  they  are  received.  If any  cartons  are  damaged or  missing,  write  a

 

complete and detailed description of the damage or shortage on the face of the freight bill. The carrier's agent must verify the

 

inspection and sign the description. Refuse only the damaged product, not the entire shipment.
VR must be notified of any damages and/or shortages within 30 days of receipt of the shipment, as stated in our Terms and

 

Conditions.

VEEDER-ROOT’S PREFERRED CARRIER

1. Fax Bill of Lading to V/R Customer Service at 800-234-5350.
2. Call V/R Customer Service at 800-873-3313 with the specific part numbers and quantities that were received damaged or

 

lost.

3. VR will file the claim with the carrier and replace the damaged/missing product at no charge to the customer. Customer

 

Service will work with production facility to have the replacement product shipped as soon as possible.

CUSTOMER’S PREFERRED CARRIER

1. Customer files claim with carrier.

2. Customer  may  submit  a  replacement  purchase  order.  Customer  Service  will  work  with  production  facility  to  have  the

 

replacement product shipped as soon as possible.

3. If “lost” equipment is delivered at a later date and is not needed, VR will allow a Return to Stock without a restocking fee.

4. VR will NOT be responsible for any compensation when a customer chooses their own carrier.

RETURN SHIPPING

For the parts return procedure, please follow the instructions in the “General Returned Goods Policy” pages of the “Policies and

 

Literature” section of the Veeder-Root North American Red Jacket Mechanical Products Price Book.   Veeder-Root will not accept

 

any return product without a Return Goods Authorization (RGA) number clearly printed on the outside of the package.

RESPONSIBILITIES OF THE INSTALLER AND STATION OWNER

This installation, operation and service instruction manual shall be left with the owner of the service station at which this equipment

 

is installed. Retain these instructions for future use and provide them to persons servicing or removing this equipment.

 

ã Veeder-Root 2021. All rights reserved

.

Summary of Contents for TLS-350 Series

Page 1: ...Manual No 577013 776 l Revision F TCP IP Interface Module Installation Guide...

Page 2: ...of Lading to V R Customer Service at 800 234 5350 2 Call V R Customer Service at 800 873 3313 with the specific part numbers and quantities that were received damaged or lost 3 VR will file the claim...

Page 3: ...Appendix A TCP IP Configuration Check List TCP IP Card IP Address Configuration Check List A 1 TCP IP TLS Setup Check List A 2 Figures Figure 1 TCP IP interface module component locations 4 Figure 2...

Page 4: ...m Setup Selections S SAT board type V21 later console software 9 Table 3 Network Connection Activity LED Codes ref view in Figure 8 10 Table 4 Telnet Setup Menu Settings Consoles with V15 20 Software...

Page 5: ...tion guide P N 577013 776 3330020 424 includes the screws 330020 425 includes the wiring harness Contractor Certification Requirements Service Technician Certification Previously known as Level 2 3 Co...

Page 6: ...A potential shock hazard exists TURN POWER OFF Live power to a device creates a potential shock hazard Turn Off power to the device and asso ciated accessories when servicing the unit READ ALL RELATE...

Page 7: ...8 and 4 Setting up the module s IP Address Configuration using either Telnet page 15 or a browser page 23 Verifying TCP IP Interface Module Configuration Key components of the TCP IP Interface module...

Page 8: ...of the console Attach securing screw from kit see Figure 3 Leave the console door open Figure 1 TCP IP interface module component locations Legend for numbered boxes in Figure 1 1 End plate for TLS 30...

Page 9: ...ace Module in the Console 5 Legend for numbered boxes in Figure 2 1 Battery backup switch S1 shown in On position to left 2 Remove knockout blank to install TCP IP module 3 Connector for TCP IP module...

Page 10: ...or numbered boxes in Figure 3 1 TX red 2 RX green 3 Bracket secured in notch 4 Remove blank in console base for access to module s plug in connector 5 4 40 x 0 312 taptite screw T 10 Torx drive 6 Modu...

Page 11: ...module into the open slot until the motherboard connector is snugly seated Do not apply excessive force when installing the module With your thumb push in the black retaining fastener on the end plate...

Page 12: ...E key to access Diag Mode Press FUNCTION key to access System Diagnostic Press the STEP key to view the software revision level Where YY equals the console s installed software For example if the vers...

Page 13: ...5 Depending on displayed board type S SAT and the console s installed software revision level select the Comm board setup parameters shown in Table 1 or Table 2 as applicable Connect a PC or Laptop to...

Page 14: ...the top edge of the RJ 45 connector should remain On when a proper connection is made ref Table 3 Legend For Numbered Boxes In Figure 7 1 PC 2 Plugs into PC Ethernet card 3 Ethernet cable 4 Hub 5 Do...

Page 15: ...as shown in Table 3 4 Before entering the TCP IP Interface Module s IP Address enter a static IP Address in your connected laptop IP Address setup procedures for both Windows 7 and 10 are discussed i...

Page 16: ...ace Module 12 Figure 10 Network Screen 2 Select Network and Sharing Center Figure 11 Figure 11 Select Network and Sharing Center 3 Select Local Area Connection Figure 12 Windows 10 computers display E...

Page 17: ...ation Connect a PC or Laptop to the TCP IP Interface Module 13 4 Select Properties Figure 13 Figure 13 Select Properties 5 Select Internet Protocol Version 4 TCP IPv4 Figure 14 Figure 14 Select Intern...

Page 18: ...e For example if the IP Address for the TCP IP module is 10 2 1 51 enter 10 2 1 50 for the laptop s IP Address For the subnet mask use 255 255 255 0 as shown in Figure 15 Leave the Default Gateway bla...

Page 19: ...t address A host wishing to obtain a physical address broadcasts an ARP request onto the TCP IP network The host on the network that has the IP address in the request then replies with its physical ha...

Page 20: ...ring the TCP IP Interface Module s IP Address 1 On new computers Telnet must be manually turned before the TCP IP Interface Module can be configured If Telnet has already been activated continued to s...

Page 21: ...paces between words and letters in all entries must be entered as shown or the address will not be successfully assigned arp s y y y y 00 20 4a xx xx xx where y y y y is the IP address of the TCP IP m...

Page 22: ...gure 16 Enter the required TCP IP Interface Mod ule s configuration settings shown in Table 4 if your console has software versions 15 20 or enter the set tings in Table 6 if your console has software...

Page 23: ...ction Remote IP Adr IP address of the computer the console will call on dialout Example 010 002 001 0591 Remote port port of the remote computer Disconn Mode 80 with DTR drop Flush Mode 00 Disconn Tim...

Page 24: ...55 255 255 252 Not Recommended 255 255 255 248 3 255 255 255 240 4 255 255 255 224 5 255 255 255 192 6 255 255 255 128 7 255 255 255 0 8 255 255 254 0 9 255 255 252 0 10 255 255 248 0 11 255 255 240 0...

Page 25: ...onnection Remote IP Adr IP address of the computer the console will call on dialout Example 010 002 001 0591 Remote port port of the remote computer Disconn Mode 80 with DTR drop Flush Mode 00 Disconn...

Page 26: ...10001 where y y y y is the IP address of the TCP IP Interface Module and 10001 is the port number Make sure you enter spaces as shown 2 Press Enter A blank screen will appear 3 Type ctrl A 200 4 Press...

Page 27: ...rovider must provide Gateway Server Router Address 6 Assign Netmask of 255 255 255 0 unless otherwise specified by Customer Network Administrator Note Customer IT department or Internet provider must...

Page 28: ...ence TLS 3XX System Setup manual Communication Setup for details 2 To ensure the TLS can call out alarms verify that Receiver Setup is complete and alarms are assigned to the proper receiver Reference...

Page 29: ......