Introduction
Activating the Display
6
Activating the Display
OEM MESSAGE DISABLED
Display is blank after the 30 second timeout. Press a button on the display, if the timeout follows setup, the pre-
dispense default mode is displayed. Otherwise the display on the screen prior to the timeout will display.
OEM MESSAGE ENABLED
Display is blank after 30 second timeout. Press a button on the display, the OEM message scrolls in the
Descriptor field. Press a button on the display, if the timeout follows setup, the pre-dispense default mode is
displayed. Otherwise the display on the screen prior to the timeout will display.
Display Value Fields
REGISTER FIELD
Six digits display the current volume, currency value, final price, or rate of fuel dispensed. The area is used to
display different selections. Values may display in various resolutions by selecting options in the C&C Mode.
Decimal and comma selection is available in this mode for 5 of the 6 digits.
PRESET FIELD
Six digits display the volume preset, volume preset count down, price, currency preset values, currency preset
count down or tank load. The area is used to enter different selections of price, volume preset, currency preset, or
modify tank load. Values may display in various resolutions by selecting options in the C&C Mode. Decimal and
comma selection is available in this mode for 5 of the 6 digits.
TOTALIZER FIELD
Eight digits display the grand totalizer volume dispensed for the life of the product. Decimal selection is available in
this mode for 2 of the 8 digits.
DESCRIPTOR FIELD
Fourteen Characters at one time, with a rolling text capability for extended messages (up to 24 characters total),
displays description of values, labels, time/date, and instructional messages. labels, descriptions, and messages
are changeable in C&C Mode. Error codes will appear also in this field.
Display icons and indicators
•
Emergency Stop
- Octagon icon displayed when optional emergency stop switch contacts are closed (they
can be active open or closed, configurable in C&C mode). This remote switch will be mounted near the Display
Head and is pushed to stop flow and pulled to resume flow.
•
Fueling
- Fuel nozzle icon displayed constantly when system is ready to dispense. The Icon will flash when
approaching the time-out in delivery mode (30 seconds). See single delivery mode for further explanation.
•
Temperature
- The thermometer icon will display only when a temperature compensated product is selected.
•
Printer
- A page icon will display only when a printer is configured for the system. A slow flashing page icon is
displayed when the printer is actively printing. A fast flashing page icon is displayed when the printer requires
operator attention.
•
Multiple Delivery
- The multi-tank icon will display when the multiple delivery state is initiated.
•
Mode Indicators
- An indicator icon will point to the current Mode (Volume, Currency, Rate, or Setup) when
appropriate.