Vector START-IT 450 AMP JUMP-START SYSTEM Instruction Manual Download Page 6

5

Controls and Indicators

CHARGING/RECHARGING

Lead-acid batteries require routine maintenance to ensure a full charge and long battery life. All batteries lose
energy from self-discharge over time and more rapidly when they are at higher temperatures. Therefore, batteries
need periodic charging to replace energy lost through self-discharge. When the unit is not in frequent use, Black
& Decker recommends the battery be recharged at least every 60 days.
Check the battery charge level by pressing the battery status button. The LED charge
status display will indicate the level of battery charge. When only one red LED lights,
recharge the unit.
When the battery is overly discharged and if the green LED is lit when the charger is 
plugged in, this indicates the battery is at a high impedance stage. 
In this event, recharge the unit and leave the unit on charge for a period of 48 hrs before
using the unit. 

Notes:

This unit is delivered in a partially charged state – you must fully charge it before using it for
the first time. Initial AC charge should be for 48 hours.

Recharging battery after each use will prolong battery life; frequent heavy discharges
between recharges and/or overcharging will reduce battery life. The battery can be  
recharged using the AC Charging Adapter (shown).
Make sure all other unit functions are turned OFF during recharging, as this can
slow the recharging process.

120 Volt AC Charging Method

The 120 Volt AC Charging Adapter is a UL listed “wall” type unit that operates from any 120 volt, 60 Hz AC
supply that has a standard North American outlet. The adapter has a barrel connector that plugs into the unit’s
Recharging Port. Make sure the Jump-Starter Power Switch and Area Light Power Switch are turned OFF
during AC charging/recharging. When the 120 Volt AC Charging Adapter is plugged into the 12 Volt DC
Recharging Port, the Battery Charge Status LED Indicators will automatically light. As recharge progresses, the
red LEDs will light, one by one. Charge the unit until one red, two yellow and one green LED indicators are lit.
Continue to recharge for one to two hours, then disconnect the Charging Adapter.

Note:

The unit cannot be overcharged using this method.

Viewing Battery Charge Status

Press the Battery Status Pushbutton located on the unit’s front panel. The four LEDs that make up the Battery
Status Display will light according to the unit’s level of charge, where one light indicates the unit requires
recharging and all four lit indicates that the unit is fully charged and ready to operate.

1.  CHARGING PORT FOR 120 VOLT AC

CHARGING ADAPTER

2. BATTERY CHARGE LEVEL PUSHBUTTON
3. LED BATTERY STATUS INDICATORS

4. JUMP-STARTER POWER SWITCH
5. REVERSE POLARITY INDICATOR
6. NEGATIVE (–) BLACK CLAMP 
7. POSITIVE (+) RED CLAMP

Front View

Back View

120 VOLT AC

CHARGING ADAPTER

1

2

3

4

5

6

7

90527010 VEC012 EN SP.qxp:VEC012_ManualEN_090407  9/11/09  8:17 AM  Page 5

Summary of Contents for START-IT 450 AMP JUMP-START SYSTEM

Page 1: ...r com NewOwner to register your new product PLEASE READ BEFORE RETURNING THIS PRODUCT FOR ANY REASON If you have a question or experience a problem with your Black Decker purchase go to HTTP WWW BLACK...

Page 2: ...Don t carry plugged in appliance with finger on switch Be sure switch is off when plugging in ELECTRICAL FAULT CIRCUIT INTERRUPTOR protection should be provided on the circuits or outlets to be used...

Page 3: ...umber size and shape as those in the charger b the extension cord is properly wired and in good electrical condition c the wire size is large enough for the AC rating of the charger as indicated in th...

Page 4: ...g this unit close to the vehicle s battery and engine stand the unit on a flat stable surface and be sure to keep all clamps cords clothing and body parts away from moving vehicle parts Never allow RE...

Page 5: ...NSTRUCTIONS THIS MANUAL CONTAINS IMPORTANT SAFETY AND OPERATING INSTRUCTIONS FOR THE START IT 450 AMP JUMP START SYSTEM MODEL VEC012 WARNING TO REDUCE THE RISK OF INJURY Follow these instructions and...

Page 6: ...arging as this can slow the recharging process 120 Volt AC Charging Method The 120 Volt AC Charging Adapter is a UL listed wall type unit that operates from any 120 volt 60 Hz AC supply that has a sta...

Page 7: ...nd NEGATIVE terminals are incorrect the Reverse Polarity Indicator will light red and the unit will sound a beep Disconnect clamps and reconnect to battery with correct polarity If vehicle fails to st...

Page 8: ...thorized Service Center for repair or replacement at our option Proof of purchase may be required Black Decker owned and authorized Service Centers are listed under Tools Electric in the yellow pages...

Page 9: ...S Si no encuentra la respuesta o no tiene acceso a Internet llame al 1 800 544 6986 de lunes a viernes de 8 a m a 5 p m hora del Este para hablar con un agente Cuando llame tenga a mano el n mero de c...

Page 10: ...uptor est apagado cuando lo enchufe LA PROTECCI N DEL INTERRUPTOR DEL CIRCUITO DE LA AVER A EL CTRICA se debe proporcionar en los circuitos o los enchufes que se utilizar n Los recept culos est n disp...

Page 11: ...icos Estas bater as pueden estallar y provocar lesiones a las personas y da os a la propiedad Use la unidad para carga refuerzo solamente de una bater a de PLOMO CIDO No est dise ada para proveer ener...

Page 12: ...ab n en el caso de que el cido de la bater a entre en contacto con la piel Si el cido de la bater a entra en contacto con la piel o la ropa lave inmediatamente con agua y jab n durante al menos 10 min...

Page 13: ...tema de bater a de 6 voltios o 24 voltios Este sistema no est dise ado para ser utilizado en reemplazo de una bater a de veh culo No intente hacer funcionar un veh culo que no tenga la bater a instala...

Page 14: ...al menos cada 60 d as Controle el nivel de carga de la bater a oprimiendo el bot n de estado de la bater a El indicador LED de estado de carga mostrar el nivel de carga de la bater a Recargue la unida...

Page 15: ...nte de sus respectivas leng etas Conecte primero la pinza roja luego la pinza negra 4 Procedimiento para arrancar mediante puente un SISTEMA CON NEGATIVO A TIERRA el terminal de la bater a est conecta...

Page 16: ...onal capacitado dispuesto a brindar a los clientes un servicio eficiente y confiable en la reparaci n de herramientas el ctricas Si necesita consejo t cnico reparaciones o piezas de repuesto originale...

Page 17: ...a operaci n est sujeta a las dos condiciones siguientes 1 este dispositivo no puede causar interferencia perjudicial y 2 este mecanismo debe aceptar cualquier interferencia recibida incluida la interf...

Reviews: