• This equipment employs parts (switches, relays, etc.) that produce arcs or sparks. Therefore, if used in a garage

or enclosed area, the unit MUST be placed not less than 18 inches above the floor.

• THIS UNIT IS NOT FOR USE BY CHILDREN AND SHOULD ONLY BE OPERATED BY ADULTS.

CAUTION: TO REDUCE THE RISK OF INJURY OR PROPERTY DAMAGE:

• Pull cord by plug rather than cord when disconnecting the 120V AC Charging Adapter from the unit.
• NEVER ATTEMPT TO JUMP-START OR CHARGE A FROZEN BATTERY.
• To recharge this unit, use only the supplied AC Charging Adapter.
• Vehicles that have on-board computerized systems may be damaged if vehicle battery is jump-started. Before

jump-starting, read the vehicle’s owner’s manual to confirm that external-starting assistance 
is suitable.

• When working with lead acid batteries, always make sure immediate assistance is available in case of accident

or emergency.

• Always have protective eyewear when using this product: contact with battery acid may cause blindness and/or

severe burns. Be aware of first aid procedures in case of accidental contact with battery acid.

• Have plenty of fresh water and soap nearby in case battery acid contacts skin.
• If battery acid contacts skin or clothing, wash immediately with soap and water for at least 10 minutes and get

medical attention immediately.

• Never smoke or allow a spark or flame in vicinity of vehicle battery, engine or power station
• Remove personal metal items such as rings, bracelets, necklaces and watches when working with a lead acid

battery. A lead acid battery can produce a short circuit current high enough to weld a ring, or similar metal
object, to skin, causing a severe burn.

• Do not wear vinyl clothing when jump-starting a vehicle when jump-starting a vehicle, friction can cause

dangerous static-electrical sparks.

• Jump-start procedures should only be performed in a safe, dry, well-ventilated area.
• Always store battery clamps when not in use. Never touch battery clamps together. This can cause dangerous

sparks, power arcing and/or explosion.

• When using this unit close to the vehicle’s battery and engine, stand the unit on a flat, stable surface, and be

sure to keep all clamps, cords, clothing and body parts away from moving vehicle parts.

• Never allow RED and BLACK clamps to touch each other or another common metal conductor — this could

cause damage to the unit and/or create a sparking/explosion hazard.
a) For negative-grounded systems, connect the POSITIVE (RED) clamp to the POSITIVE ungrounded battery

post and the NEGATIVE (BLACK) clamp to the vehicle chassis or engine block away from the battery. Do not
connect the clamp to the carburetor, fuel lines or sheet-metal body parts. Connect to a heavy gauge metal part
of the frame or engine block.

b) For positive-grounded systems, connect the NEGATIVE (BLACK) clamp to the NEGATIVE ungrounded battery

post and the POSITIVE (RED) clamp to the vehicle chassis or engine block away from the battery. Do not
connect the clamp to the carburetor, fuel lines or sheet-metal body parts. Connect to a heavy gauge metal part
of the frame or engine block.

• If the connections to the battery’s POSITIVE and NEGATIVE terminals are incorrect, the Reverse Polarity

Indicator will light (red) and the unit will sound a beep.  Disconnect clamps and reconnect to battery with
correct polarity.

• Always disconnect the NEGATIVE (BLACK) jumper cable first, followed by the POSITIVE (RED) jumper cable,

except for positive grounded systems.

• Do not expose battery to fire or intense heat since it may explode. Before disposing of the battery, protect

exposed terminals with heavy-duty electrical tape to prevent shorting (shorting can result in injury or fire).

• Place this unit as far away from the battery as cables permit.
• Never allow battery acid to come in contact with this unit.
• Do not operate this unit in a closed area or restrict ventilation in any way.

FIRST AID

– SKIN: If battery acid comes in contact with skin, rinse immediately with water, then wash

thoroughly with soap and water. If redness, pain, or irritation occurs, seek immediate medical attention.
EYES: If battery acid comes in contact with eyes, flush eyes immediately, for a minimum of 15 minutes and
seek immediate medical attention. 

90527010 VEC012 EN SP.qxp:VEC012_ManualEN_090407  9/11/09  8:17 AM  Page 3

Summary of Contents for START-IT 450 AMP JUMP-START SYSTEM

Page 1: ...r com NewOwner to register your new product PLEASE READ BEFORE RETURNING THIS PRODUCT FOR ANY REASON If you have a question or experience a problem with your Black Decker purchase go to HTTP WWW BLACK...

Page 2: ...Don t carry plugged in appliance with finger on switch Be sure switch is off when plugging in ELECTRICAL FAULT CIRCUIT INTERRUPTOR protection should be provided on the circuits or outlets to be used...

Page 3: ...umber size and shape as those in the charger b the extension cord is properly wired and in good electrical condition c the wire size is large enough for the AC rating of the charger as indicated in th...

Page 4: ...g this unit close to the vehicle s battery and engine stand the unit on a flat stable surface and be sure to keep all clamps cords clothing and body parts away from moving vehicle parts Never allow RE...

Page 5: ...NSTRUCTIONS THIS MANUAL CONTAINS IMPORTANT SAFETY AND OPERATING INSTRUCTIONS FOR THE START IT 450 AMP JUMP START SYSTEM MODEL VEC012 WARNING TO REDUCE THE RISK OF INJURY Follow these instructions and...

Page 6: ...arging as this can slow the recharging process 120 Volt AC Charging Method The 120 Volt AC Charging Adapter is a UL listed wall type unit that operates from any 120 volt 60 Hz AC supply that has a sta...

Page 7: ...nd NEGATIVE terminals are incorrect the Reverse Polarity Indicator will light red and the unit will sound a beep Disconnect clamps and reconnect to battery with correct polarity If vehicle fails to st...

Page 8: ...thorized Service Center for repair or replacement at our option Proof of purchase may be required Black Decker owned and authorized Service Centers are listed under Tools Electric in the yellow pages...

Page 9: ...S Si no encuentra la respuesta o no tiene acceso a Internet llame al 1 800 544 6986 de lunes a viernes de 8 a m a 5 p m hora del Este para hablar con un agente Cuando llame tenga a mano el n mero de c...

Page 10: ...uptor est apagado cuando lo enchufe LA PROTECCI N DEL INTERRUPTOR DEL CIRCUITO DE LA AVER A EL CTRICA se debe proporcionar en los circuitos o los enchufes que se utilizar n Los recept culos est n disp...

Page 11: ...icos Estas bater as pueden estallar y provocar lesiones a las personas y da os a la propiedad Use la unidad para carga refuerzo solamente de una bater a de PLOMO CIDO No est dise ada para proveer ener...

Page 12: ...ab n en el caso de que el cido de la bater a entre en contacto con la piel Si el cido de la bater a entra en contacto con la piel o la ropa lave inmediatamente con agua y jab n durante al menos 10 min...

Page 13: ...tema de bater a de 6 voltios o 24 voltios Este sistema no est dise ado para ser utilizado en reemplazo de una bater a de veh culo No intente hacer funcionar un veh culo que no tenga la bater a instala...

Page 14: ...al menos cada 60 d as Controle el nivel de carga de la bater a oprimiendo el bot n de estado de la bater a El indicador LED de estado de carga mostrar el nivel de carga de la bater a Recargue la unida...

Page 15: ...nte de sus respectivas leng etas Conecte primero la pinza roja luego la pinza negra 4 Procedimiento para arrancar mediante puente un SISTEMA CON NEGATIVO A TIERRA el terminal de la bater a est conecta...

Page 16: ...onal capacitado dispuesto a brindar a los clientes un servicio eficiente y confiable en la reparaci n de herramientas el ctricas Si necesita consejo t cnico reparaciones o piezas de repuesto originale...