Vector START-IT 450 AMP JUMP-START SYSTEM Instruction Manual Download Page 5

4

IMPORTANT: 

This unit is delivered in a partially charged state. Fully charge unit with a household extension

cord (not supplied) for a full 48 hours before using for the first time. You cannot overcharge the unit using the
AC charging method.

• All On/Off switches should be in the OFF position when the unit is charging or not in use. Make sure all

switches are in the OFF position before connection to a power source or load.

• Do not use any accessory that is not recommended or provided by the manufacturer.
• This system is designed to be used only on vehicles with a 12 volt DC battery system. Do not connect to a 6

volt or 24 volt battery system.

• This system is not designed to be used as a replacement for a vehicular battery. Do not attempt to operate a

vehicle that does not have a battery installed.

• Excessive engine cranking can damage a vehicle’s starter motor. If the engine fails to start after the

recommended number of attempts, discontinue jump-start procedures and look for other problems that may
need to be corrected.

• Do not use this jump-starter on a watercraft. It is not qualified for marine applications.
• Although this unit contains a non-spillable battery, it is recommended that unit be kept upright during storage,

use and recharging. To avoid possible damage that may shorten the unit’s working life, protect it from direct
sunlight, direct heat and/or moisture.

• Read And Understand This Instruction Manual Before Using This Unit.

SAVE THESE INSTRUCTIONS

THIS MANUAL CONTAINS IMPORTANT SAFETY AND OPERATING INSTRUCTIONS FOR THE START-IT

®

450 AMP JUMP-

START SYSTEM MODEL VEC012.

WARNING: TO REDUCE THE RISK OF INJURY:

• Follow these instructions and those published by the battery manufacturer and manufacturer of any equipment

you intend to use with this unit. Review cautionary markings on these products and on engine.

INTRODUCTION

Thank you for choosing the 

Start-It

®

450 Amp Jump-Start System

. This compact jump-starter is unique in the

amount of energy it can supply for its size. The internal battery is a high density sealed, lead-acid battery that
stores and delivers energy comparable to full sized ordinary jump-starters. Please read this guide carefully
before use to ensure optimum performance and avoid damage to the unit or items that you are using it with. 
The 

Start-It

®

450 Amp Jump-Start System 

is a compact, durable, portable jump-start system for vehicles that

have a standard 12 volt battery system. This self-contained, rechargeable system will start most vehicles
without the need for a host vehicle or 12 volt DC power supply.

FEATURES

• 450 instant starting amps
• Keyless ON/OFF Power Switch
• Built-in non-spillable, maintenance-free, heavy duty, 17 amp/hour, sealed, lead-acid battery
• Easy-to-read LED battery charge status indicators
• Reverse polarity connection warning indicator
• Cordless/rechargeable, includes 120 Volt AC Charging Adapter
• Requires no maintenance (other than recharging) for optimum operation
• Heavy duty cables and clamps
• Exclusive cable storage channels keep jumper cables out of the way until needed 

90527010 VEC012 EN SP.qxp:VEC012_ManualEN_090407  9/11/09  8:17 AM  Page 4

Summary of Contents for START-IT 450 AMP JUMP-START SYSTEM

Page 1: ...r com NewOwner to register your new product PLEASE READ BEFORE RETURNING THIS PRODUCT FOR ANY REASON If you have a question or experience a problem with your Black Decker purchase go to HTTP WWW BLACK...

Page 2: ...Don t carry plugged in appliance with finger on switch Be sure switch is off when plugging in ELECTRICAL FAULT CIRCUIT INTERRUPTOR protection should be provided on the circuits or outlets to be used...

Page 3: ...umber size and shape as those in the charger b the extension cord is properly wired and in good electrical condition c the wire size is large enough for the AC rating of the charger as indicated in th...

Page 4: ...g this unit close to the vehicle s battery and engine stand the unit on a flat stable surface and be sure to keep all clamps cords clothing and body parts away from moving vehicle parts Never allow RE...

Page 5: ...NSTRUCTIONS THIS MANUAL CONTAINS IMPORTANT SAFETY AND OPERATING INSTRUCTIONS FOR THE START IT 450 AMP JUMP START SYSTEM MODEL VEC012 WARNING TO REDUCE THE RISK OF INJURY Follow these instructions and...

Page 6: ...arging as this can slow the recharging process 120 Volt AC Charging Method The 120 Volt AC Charging Adapter is a UL listed wall type unit that operates from any 120 volt 60 Hz AC supply that has a sta...

Page 7: ...nd NEGATIVE terminals are incorrect the Reverse Polarity Indicator will light red and the unit will sound a beep Disconnect clamps and reconnect to battery with correct polarity If vehicle fails to st...

Page 8: ...thorized Service Center for repair or replacement at our option Proof of purchase may be required Black Decker owned and authorized Service Centers are listed under Tools Electric in the yellow pages...

Page 9: ...S Si no encuentra la respuesta o no tiene acceso a Internet llame al 1 800 544 6986 de lunes a viernes de 8 a m a 5 p m hora del Este para hablar con un agente Cuando llame tenga a mano el n mero de c...

Page 10: ...uptor est apagado cuando lo enchufe LA PROTECCI N DEL INTERRUPTOR DEL CIRCUITO DE LA AVER A EL CTRICA se debe proporcionar en los circuitos o los enchufes que se utilizar n Los recept culos est n disp...

Page 11: ...icos Estas bater as pueden estallar y provocar lesiones a las personas y da os a la propiedad Use la unidad para carga refuerzo solamente de una bater a de PLOMO CIDO No est dise ada para proveer ener...

Page 12: ...ab n en el caso de que el cido de la bater a entre en contacto con la piel Si el cido de la bater a entra en contacto con la piel o la ropa lave inmediatamente con agua y jab n durante al menos 10 min...

Page 13: ...tema de bater a de 6 voltios o 24 voltios Este sistema no est dise ado para ser utilizado en reemplazo de una bater a de veh culo No intente hacer funcionar un veh culo que no tenga la bater a instala...

Page 14: ...al menos cada 60 d as Controle el nivel de carga de la bater a oprimiendo el bot n de estado de la bater a El indicador LED de estado de carga mostrar el nivel de carga de la bater a Recargue la unida...

Page 15: ...nte de sus respectivas leng etas Conecte primero la pinza roja luego la pinza negra 4 Procedimiento para arrancar mediante puente un SISTEMA CON NEGATIVO A TIERRA el terminal de la bater a est conecta...

Page 16: ...onal capacitado dispuesto a brindar a los clientes un servicio eficiente y confiable en la reparaci n de herramientas el ctricas Si necesita consejo t cnico reparaciones o piezas de repuesto originale...

Page 17: ...a operaci n est sujeta a las dos condiciones siguientes 1 este dispositivo no puede causar interferencia perjudicial y 2 este mecanismo debe aceptar cualquier interferencia recibida incluida la interf...

Reviews: