background image

7

battery connections are tight and the battery (or batteries) is (are) fully-charged. If the
connections are good and the battery is charged, but the voltage still drops below 11
volts, you may need to use a larger battery (or battery combination).

CAUTION

Rechargeable Devices
Certain rechargeable devices do not operate well from a modified sine
wave inverter. They only operate properly from a standard household
outlet, which provides a pure sine wave. Therefore, the manufacturer
recommends that these types of devices be operated from a standard
household outlet only, not from the inverter.
This problem does not occur with most battery-operated equipment.
Most of these devices use a separate charger or transformer that is
plugged into an AC receptacle. This inverter is easily capable of
running most chargers and transformers.

OPERATING INSTRUCTIONS
Power Source Requirements

The inverter will operate from input voltages between 11 and 15 volts DC. If the
voltage drops below 10.6 volts, an audible low battery warning alarm will sound.
The inverter will shut down if the input voltage drops below 10.5 volts DC. This built-
in feature protects the battery from being completely discharged.
The inverter will also shut down if the input voltage exceeds 15.5 volts. This 
protects the inverter against excessive input voltage. Although the inverter has built-in
protection against over voltage, it may still be damaged if the input voltage exceeds
15.5 volts.
Inductive loads, such as TVs and stereos, require more current to operate than do
resistive loads with the same wattage rating. Induction motors, as well as some TVs,
may require two to six times their rated wattage to start up. Because  the MAXX SST

inverters have a peak watt power rating, many such appliances and tools may be
safely operated. The equipment that needs the highest starting wattage are pumps and
compressors that start under load. This equipment can be safely tested. If an overload
is detected, the inverters will simply shut down until the overload situation is corrected.
Use the front panel switch to turn OFF the inverter, then ON, to reset the inverter.

CAUTIONS

Exceeding recommended voltage limits will void manufacturer’s
warranty.
NEVER try to use the inverter with any 12 volt DC power source
that uses a POSITIVE ground. (Most vehicles and boats use negative
ground systems.)

The DC power source must be a well-regulated DC power supply as typically found
in vehicle and deep-cycle marine batteries. The DC power source may also be two
12 volt batteries connected in parallel. On larger applications the power source may
be several batteries connected in parallel as shown in the following “Battery Wiring”
diagram.

6

The following chart shows the approximate amperage and corresponding wattage at
120 volts AC for various common tools and appliances.

Appliance Consumption in Amps and Watts Chart

APPLIANCE

AMPS@ WATTS@

120VAC 120VAC

Laptop Computer

0.5 

55

Household Power Mixer

2

220

240-Watt Stereo/Amplifier

2.2

242

Refrigerator

3

330

3/8" Variable Speed Drill

3

330

Variable Speed Jig Saw

3

330

10-Speed Blender

3.2

352

Belt Sander

3.4

374

3/8" Reversible Drill

3.5

385

Household Food Processor

3.6

396

Computer and Monitor

4

440

Portable Vacuum

4.6

506

8-Cup Coffee Maker

5.5

605

Electric Trimmer

5.5

605

1/2" Hammer-Drill

5.5

605

Reciprocating Saw

6

660

Vacuum Cleaner

7.2

792

1-1/8" Rotary Hammer

7.8

858

1/6 H.P. Submersible Sump Pump

8

880

Compact Microwave Oven

8.5

935

10" Bench Saw

13.0

1500

Note:

Appliance specifications may vary from brand to brand. This table is offered
only as a guide to approximate power ratings. Check appliance manuals or
product labeling for actual ratings. For continuous use at maximum output, the
MAXX SST

inverter must be connected to a DC power supply capable of

providing at least 1/10th of the inverter’s continuous wattage rating.

The inverter will operate most AC loads within its power rating. Some induction
motors used in refrigerators, freezers, pumps and other motor-operated equipment,
require very high surge currents to start them. The inverter may not be able to start
some of these motors even though their rated current draw is within specifications for
this power inverter.
If a motor refuses to start, observe the battery voltage using a DC voltmeter while
trying to start the motor. If the battery voltmeter drops below 11 volts while the inverter
is attempting to start the motor, this may be why the motor won’t start. Make sure the

VEC049_thru_56D_Manual_092205  10/21/05  11:50 AM  Page 6

Summary of Contents for MAXX SST VEC056D

Page 1: ...USER S MANUAL WARRANTY INFORMATION IMPORTANT SAFETY INFORMATION SAVE THESE INSTRUCTIONS VEC049D VEC053D VEC050D VEC054D VEC056D VEC051D MAXX SST Compact Power Inverters Converts 12 Volt DC to 120 Vol...

Page 2: ...that cable insulation is not damaged Do not use with positive ground electrical systems Reverse polarity connection will result in a blown fuse and may cause permanent damage to the inverter and will...

Page 3: ...ses that exceed those of other mobile installations Therefore the installer operator should be especially aware of the requirements to maintain secure tight water resistant electrical connections and...

Page 4: ...shipping charges on all returned items During the warranty period manufacturer will be responsible for the return shipping charges to the customer in the United States LIMITATIONS This warranty does...

Page 5: ...carefully before use to ensure optimum performance and to avoid damage to this product This Power Inverter is configured with the latest Soft Start Technology SST and supplies continuous power and pe...

Page 6: ...Diagram Back View Diagram WATTAGE POWER METER ON OFF POWER SWITCH 2 120 VOLT AC OUTLETS RED FAULT LED INDICATOR HIGH SPEED COOLING FAN NEGATIVE TERMINALS GROUNDNG TERMINAL POSITIVE TERMINAL GREEN POWE...

Page 7: ...DC MAXX SST uses a 12 volt DC power source like those found in motor vehicles or it can be operated using multiple battery configurations with commercial battery NEGATIVE TERMINALS GROUNDING TERMINAL...

Page 8: ...wer Inverter Output Waveform The AC output waveform of the Power Inverter is known as modified sine wave It is a waveform that has characteristics similar to the sine wave shape of utility power This...

Page 9: ...ction so that if you do exceed the inverter s output capacity continuously the unit will automatically shut down Once the excessive load is removed the inverter can be restarted and resume normal oper...

Page 10: ...Cup Coffee Maker 5 5 605 Electric Trimmer 5 5 605 1 2 Hammer Drill 5 5 605 Reciprocating Saw 6 660 Vacuum Cleaner 7 2 792 1 1 8 Rotary Hammer 7 8 858 1 6 H P Submersible Sump Pump 8 880 Compact Microw...

Page 11: ...he battery from being completely discharged The inverter will also shut down if the input voltage exceeds 15 5 volts This protects the inverter against excessive input voltage Although the inverter ha...

Page 12: ...operate from the inverter To do this read the labels on the equipment to be operated 2 Estimate the number of hours the equipment will be in use between battery recharges 3 Determine the total watt ho...

Page 13: ...city Protective Features LOW BATTERY ALARM An audible alarm will sound when the 12 volt DC power supply voltage drops down to 10 5 0 3 volts This indicates that the battery needs to be charged or ther...

Page 14: ...and 105 F 40 C 3 At least three inches of clearance from other objects is maintained for cooling airflow 4 The unit is not exposed to direct heat sunlight or to explosive or flammable fumes and 5 The...

Page 15: ...responding positive and negative terminals on the 12 volt DC vehicle battery or other 12 volt DC power source There may be some minor sparking 5 Turn the inverter ON OFF Switch ON 6 Plug in a lamp wit...

Page 16: ...med the above preliminary installation steps proceed with the actual inverter installation Contact the manufacturer for any further installation information or questions You can purchase fuses fuse ho...

Page 17: ...f after following all of the above steps the inverter does not perform properly the source voltage may be too low or the cables may be too long or the gauge too light Having checked and if necessary c...

Page 18: ...rs The inverter ON OFF Switch must be in the OFF position when connecting the Remote Control to the unit or the Remote Control will not operate Once the unit has been turned ON using the Remote Contro...

Page 19: ...hat high quality shielded antenna cable is used Do not use the inverter to operate high power appliances or tools at the same time you are using it to operate the TV Make sure the inverter s case is p...

Page 20: ...15 5 0 Low Voltage Alarm 10 5 0 3 volts DC 10 5 0 3 volts DC 10 5 0 3 volts DC 10 5 0 3 volts DC 10 5 0 Low Voltage Shutdown 10 0 0 3 volts DC 10 0 0 3 volts DC 10 0 0 3 volts DC 10 0 0 3 volts DC 10...

Reviews: