background image

1

TABLE OF CONTENTS

Introduction  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

1

Features  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

1

VEC049D & VEC053D Diagrams  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

2

VEC050D & VEC054D Diagrams  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

2

VEC051D & VEC056D Diagrams  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

3

MAXX SST Safety Features  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

3

Principle of Operation  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

4

Appliance Power Consumption  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

5

Appliance Consumption in Amps and Watts Chart  . . . . . . . . . . . . . . . . . . . . . . . . . . . .

6

Operating Instructions  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

7

Power Source Requirements  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

7

Determining Battery Size  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

8

Runtime  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

8

Protective Features  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

9

Installation  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10

Operating Environment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Installation Procedures  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Connection To Load  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Operating Tips  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Notes on Using the Remote Control (sold separately)  . . . . . . . . . . . . . . . . . . . . . . . . . . . 14

Care and Maintenance  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14

Storage  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Fuse Replacement  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Preventive Maintenance  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14

Troubleshooting  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15

Common Audio/Visual Problems  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Fault Protection and Troubleshooting Guide  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15

Specifications  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16

INTRODUCTION

Thank you for purchasing a 

Vector Power Inverter.

Please read this guide carefully

before use to ensure optimum performance and to avoid damage to this product.
This Power Inverter is configured with the latest Soft Start Technology (SST) and
supplies continuous power and peak watts in the form of 120 volt AC outlets to run
most household or electronic appliances. Before introduction of SST, high start-up
currents from large inductive loads could shut down an inverter. SST improves inverter
operation by: 
• Gradual voltage ramp-up during inverter start-up, eliminating failed cold starts

under load.

• Output that momentarily dips in voltage and quickly recovers to allow large

motorized loads to start, eliminating most shutdowns from momentary overloads. 

• A new technology that cools the power transistors more efficiently, and, combined

with Soft Start, dramatically increases reliability and life of the product.

Added safety features include automatic shutdown and a low battery alarm to prevent
damage to your battery.

FEATURES

On the front panel are two LED indicators. The green LED indicates power and proper
operation of the inverter, the red LED indicates inverter shutdown from over-load or
over-temperature condition, or abnormal input voltages. The ON/OFF Switch turns
the inverter ON and OFF. The switch can also be used to force reset of inverter circuits
by switching it OFF, then back ON again. All models also feature a port to attach a
remote control (sold separately).

TWO YEAR LIMITED WARRANTY PROGRAM

This limited warranty program is the only one that applies to this product, and it sets forth all the

responsibilities of Vector Manufacturing, regarding this product. There is no other warranty, other than

those described herein. Any implied warranty of merchantability or fitness for a particular purpose on

this product is limited in duration to the duration of this warranty.
This Vector Manufacturing product is warranted, to the original purchaser only, to be free of defects in

materials and workmanship for two years from the date of purchase without additional charge. The

warranty does not extend to subsequent purchasers or users. Manufacturer will not be responsible for

any amount of damage in excess of the retail purchase price of the product under any circumstances.

Incidental and consequential damages are specifically excluded from coverage under this warranty.
This product is not intended for commercial use. This warranty does not apply to damage to units from

misuse or incorrect installation/connection. Misuse includes wiring or connecting to improper polarity

power sources.
RETURN/REPAIR POLICY: Defective products may be returned to manufacturer. Any defective product

that is returned to manufacturer within 30 days of the date of purchase will be replaced free of charge.

If such a product is returned more than 30 days but less than two years from the purchase date,

manufacturer will repair the unit or, at its option, replace it, free of charge.
If the unit is repaired, new or reconditioned replacement parts may be used, at manufacturer’s option.

A unit may be replaced with a new or reconditioned unit of the same or comparable design. The

repaired or replaced unit will then be warranted under the terms of the remainder of the warranty

period. The customer is responsible for the shipping charges on all returned items. During the warranty

period, manufacturer will be responsible for the return shipping charges to the customer in the United

States.
LIMITATIONS: This warranty does not cover accessories, such as charging adapters, bulbs, fuses and

batteries, damage or defects resulting from normal wear and tear (including chips, scratches, abrasions,

discoloration or fading due to usage or exposure to sunlight), accidents, damage during shipping to our

service facility, alterations, unauthorized use or repair, neglect, misuse, abuse, failure to follow

instructions for care and maintenance, fire, flood and Acts of God.
If your problem is not covered by this warranty, call our Technical Support Department at (954) 584-

4446 or toll free at (866) 584-5504 for general repair information and charges if applicable. You may

also contact us through our website at www.vectormfg.com.
STATE LAW RIGHTS: This warranty gives you specific legal rights. Some states do not allow limitations

on how long an implied warranty lasts or the exclusion or limitation of incidental or consequential

damages, so the exclusions or limitations stated herein may not apply. This warranty gives the purchaser

specific legal rights; other rights, which vary from state to state, may apply.
TO REQUEST WARRANTY SERVICE FOR THIS PRODUCT: Contact Technical Support by telephone, fax

or mail (see below). We suggest that you keep the original packaging in case you need to ship the unit.

When returning a product, include your name, address, phone number, dated sales receipt (or copy)

and a description of the reason for return and product serial number. After repairing or replacing the

unit, we will make every effort to return it to you within four weeks.
WARRANTY ACTIVATION: Please complete Warranty Activation Card and mail to Vector

Manufacturing. Enter the appropriate model number as Model and “MAXX SST

Compact Power

Inverter” as Product Type. All Vector products must be registered within 30 days of purchase to activate

this warranty. Mail the completed registration form, along with a copy of the original sales receipt, to:

ATTN.: CUSTOMER SERVICE 

4140 SW 30th Ave., Ft. Lauderdale, FL 33312 

• TOLL FREE: (866 ) 584-5504 • FAX: (954) 584-5556 •

WARRANTY IS NON-TRANSFERABLE.

BD090705

© 2005 VECTOR MANUFACTURING

MADE IN CHINA

VEC049_thru_56D_Manual_092205  10/21/05  11:50 AM  Page iv

Summary of Contents for MAXX SST VEC056D

Page 1: ...USER S MANUAL WARRANTY INFORMATION IMPORTANT SAFETY INFORMATION SAVE THESE INSTRUCTIONS VEC049D VEC053D VEC050D VEC054D VEC056D VEC051D MAXX SST Compact Power Inverters Converts 12 Volt DC to 120 Vol...

Page 2: ...that cable insulation is not damaged Do not use with positive ground electrical systems Reverse polarity connection will result in a blown fuse and may cause permanent damage to the inverter and will...

Page 3: ...ses that exceed those of other mobile installations Therefore the installer operator should be especially aware of the requirements to maintain secure tight water resistant electrical connections and...

Page 4: ...shipping charges on all returned items During the warranty period manufacturer will be responsible for the return shipping charges to the customer in the United States LIMITATIONS This warranty does...

Page 5: ...carefully before use to ensure optimum performance and to avoid damage to this product This Power Inverter is configured with the latest Soft Start Technology SST and supplies continuous power and pe...

Page 6: ...Diagram Back View Diagram WATTAGE POWER METER ON OFF POWER SWITCH 2 120 VOLT AC OUTLETS RED FAULT LED INDICATOR HIGH SPEED COOLING FAN NEGATIVE TERMINALS GROUNDNG TERMINAL POSITIVE TERMINAL GREEN POWE...

Page 7: ...DC MAXX SST uses a 12 volt DC power source like those found in motor vehicles or it can be operated using multiple battery configurations with commercial battery NEGATIVE TERMINALS GROUNDING TERMINAL...

Page 8: ...wer Inverter Output Waveform The AC output waveform of the Power Inverter is known as modified sine wave It is a waveform that has characteristics similar to the sine wave shape of utility power This...

Page 9: ...ction so that if you do exceed the inverter s output capacity continuously the unit will automatically shut down Once the excessive load is removed the inverter can be restarted and resume normal oper...

Page 10: ...Cup Coffee Maker 5 5 605 Electric Trimmer 5 5 605 1 2 Hammer Drill 5 5 605 Reciprocating Saw 6 660 Vacuum Cleaner 7 2 792 1 1 8 Rotary Hammer 7 8 858 1 6 H P Submersible Sump Pump 8 880 Compact Microw...

Page 11: ...he battery from being completely discharged The inverter will also shut down if the input voltage exceeds 15 5 volts This protects the inverter against excessive input voltage Although the inverter ha...

Page 12: ...operate from the inverter To do this read the labels on the equipment to be operated 2 Estimate the number of hours the equipment will be in use between battery recharges 3 Determine the total watt ho...

Page 13: ...city Protective Features LOW BATTERY ALARM An audible alarm will sound when the 12 volt DC power supply voltage drops down to 10 5 0 3 volts This indicates that the battery needs to be charged or ther...

Page 14: ...and 105 F 40 C 3 At least three inches of clearance from other objects is maintained for cooling airflow 4 The unit is not exposed to direct heat sunlight or to explosive or flammable fumes and 5 The...

Page 15: ...responding positive and negative terminals on the 12 volt DC vehicle battery or other 12 volt DC power source There may be some minor sparking 5 Turn the inverter ON OFF Switch ON 6 Plug in a lamp wit...

Page 16: ...med the above preliminary installation steps proceed with the actual inverter installation Contact the manufacturer for any further installation information or questions You can purchase fuses fuse ho...

Page 17: ...f after following all of the above steps the inverter does not perform properly the source voltage may be too low or the cables may be too long or the gauge too light Having checked and if necessary c...

Page 18: ...rs The inverter ON OFF Switch must be in the OFF position when connecting the Remote Control to the unit or the Remote Control will not operate Once the unit has been turned ON using the Remote Contro...

Page 19: ...hat high quality shielded antenna cable is used Do not use the inverter to operate high power appliances or tools at the same time you are using it to operate the TV Make sure the inverter s case is p...

Page 20: ...15 5 0 Low Voltage Alarm 10 5 0 3 volts DC 10 5 0 3 volts DC 10 5 0 3 volts DC 10 5 0 3 volts DC 10 5 0 Low Voltage Shutdown 10 0 0 3 volts DC 10 0 0 3 volts DC 10 0 0 3 volts DC 10 0 0 3 volts DC 10...

Reviews: