Important Cable Information

Substantial power loss and reduced battery operating time results from inverters installed with cables that

are not able to supply full power. Symptoms of low battery power can result from cables that are either

excessively long or an insufficient gauge. Marine installations are also subjected to vibration and stresses

that exceed those of other mobile installations. Therefore, the installer/operator should be especially

aware of the requirements to maintain secure, tight, water-resistant electrical connections and to provide

for strain relief for DC cables and appliance wiring. Cable insulation must be the appropriate type for

the environment.

Read All Instructions Before Using This Power Inverter!

SAVE THESE INSTRUCTIONS

IMPORTANT SAFETY INSTRUCTIONS 

To ensure reliable service, your power inverter must be installed and used properly. Please read the

installation and operating instructions thoroughly prior to installation and use. Pay particular attention to

the WARNING and CAUTION statements in this User’s Manual. The CAUTION statements advise

against certain conditions and practices that may result in damage to your inverter. The WARNING

statements identify conditions or practices that may result in personal injury.

WARNINGS
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, EXPLOSION OR INJURY:
• NEVER connect to AC distribution wiring.
• Remove appliance plug from outlet strip or turn off inverter before working on the

appliance. Multiple outlet power strips with switches and circuit breakers only
interrupt power to the "hot" receptacle terminals. The "neutral" terminals remain
powered with respect to the "ground" terminals.

• NOT approved for ignition protected areas. Do not make any electrical connections

or disconnections in areas designated as IGNITION PROTECTED.

• This is not a toy — keep away from children.
• This equipment employs components that tend to produce arcs or sparks. DO NOT

install in compartments containing batteries or flammable materials.

• Use this unit in properly ventilated areas ONLY.
• Do not open — there are no user-serviceable parts inside.
• Do not insert foreign objects into the outlets.
• Do not expose the unit to liquids, including water, rain or snow.

CAUTIONS

• Always inspect battery supply connections and cables to ensure they are tight and that cable insulation

is not damaged.

• Do not use with positive ground electrical systems*. Reverse polarity connection will result in a blown

fuse and may cause permanent damage to the inverter and will void warranty.

*The majority of modern automobiles, RVs, trucks and boats are negative ground.

• Grounding the Neutral will cause the inverter to shut down. Do not operate this inverter if it is wet. Do

not install in engine compartment — install in a well ventilated area.

• This inverter has not been not tested for use with medical devices.
• Do not attempt to install or operate this unit while operating a motor vehicle.

APPLIANCE CAUTIONS

NEVER plug small appliances directly into the inverter outlets to recharge nickel-cadmium batteries.
Always use the charger provided with the appliance.

NEVER plug in battery chargers for cordless power tools if the charger carries a warning that dangerous
voltages are present at the battery terminals. 

Certain chargers for small nickel-cadmium batteries can be damaged if plugged into the inverters. DO
NOT use inverters with the following two types of equipment.

1. Small, battery-operated appliances such as flashlights, cordless razors and toothbrushes that can

be plugged directly into an AC receptacle to recharge.

2. Battery chargers that have a warning label stating that dangerous voltages are present at the

battery terminals.

The majority of portable appliances do not have this problem. Most portable appliances use separate
transformers or chargers that plug into AC receptacles to supply a low DC or AC voltage output to the
appliance. If the appliance label states that the charger or adapter produces a low DC or AC voltage
output (30 volts or less), there should be no problem powering that charger or adapter.

Some fluorescent lamps may not operate properly with this type of inverter. If the bulb appears to be too
bright, or fails to light, do not use the lamp with this inverter.

Some fans with synchronous motors may slightly increase in speed (RPM) when powered by the inverter.
This is not harmful to the fan or to the inverter.

VEC049_thru_56D_Manual_092205  10/21/05  11:50 AM  Page ii

Summary of Contents for MAXX SST VEC056D

Page 1: ...USER S MANUAL WARRANTY INFORMATION IMPORTANT SAFETY INFORMATION SAVE THESE INSTRUCTIONS VEC049D VEC053D VEC050D VEC054D VEC056D VEC051D MAXX SST Compact Power Inverters Converts 12 Volt DC to 120 Vol...

Page 2: ...that cable insulation is not damaged Do not use with positive ground electrical systems Reverse polarity connection will result in a blown fuse and may cause permanent damage to the inverter and will...

Page 3: ...ses that exceed those of other mobile installations Therefore the installer operator should be especially aware of the requirements to maintain secure tight water resistant electrical connections and...

Page 4: ...shipping charges on all returned items During the warranty period manufacturer will be responsible for the return shipping charges to the customer in the United States LIMITATIONS This warranty does...

Page 5: ...carefully before use to ensure optimum performance and to avoid damage to this product This Power Inverter is configured with the latest Soft Start Technology SST and supplies continuous power and pe...

Page 6: ...Diagram Back View Diagram WATTAGE POWER METER ON OFF POWER SWITCH 2 120 VOLT AC OUTLETS RED FAULT LED INDICATOR HIGH SPEED COOLING FAN NEGATIVE TERMINALS GROUNDNG TERMINAL POSITIVE TERMINAL GREEN POWE...

Page 7: ...DC MAXX SST uses a 12 volt DC power source like those found in motor vehicles or it can be operated using multiple battery configurations with commercial battery NEGATIVE TERMINALS GROUNDING TERMINAL...

Page 8: ...wer Inverter Output Waveform The AC output waveform of the Power Inverter is known as modified sine wave It is a waveform that has characteristics similar to the sine wave shape of utility power This...

Page 9: ...ction so that if you do exceed the inverter s output capacity continuously the unit will automatically shut down Once the excessive load is removed the inverter can be restarted and resume normal oper...

Page 10: ...Cup Coffee Maker 5 5 605 Electric Trimmer 5 5 605 1 2 Hammer Drill 5 5 605 Reciprocating Saw 6 660 Vacuum Cleaner 7 2 792 1 1 8 Rotary Hammer 7 8 858 1 6 H P Submersible Sump Pump 8 880 Compact Microw...

Page 11: ...he battery from being completely discharged The inverter will also shut down if the input voltage exceeds 15 5 volts This protects the inverter against excessive input voltage Although the inverter ha...

Page 12: ...operate from the inverter To do this read the labels on the equipment to be operated 2 Estimate the number of hours the equipment will be in use between battery recharges 3 Determine the total watt ho...

Page 13: ...city Protective Features LOW BATTERY ALARM An audible alarm will sound when the 12 volt DC power supply voltage drops down to 10 5 0 3 volts This indicates that the battery needs to be charged or ther...

Page 14: ...and 105 F 40 C 3 At least three inches of clearance from other objects is maintained for cooling airflow 4 The unit is not exposed to direct heat sunlight or to explosive or flammable fumes and 5 The...

Page 15: ...responding positive and negative terminals on the 12 volt DC vehicle battery or other 12 volt DC power source There may be some minor sparking 5 Turn the inverter ON OFF Switch ON 6 Plug in a lamp wit...

Page 16: ...med the above preliminary installation steps proceed with the actual inverter installation Contact the manufacturer for any further installation information or questions You can purchase fuses fuse ho...

Page 17: ...f after following all of the above steps the inverter does not perform properly the source voltage may be too low or the cables may be too long or the gauge too light Having checked and if necessary c...

Page 18: ...rs The inverter ON OFF Switch must be in the OFF position when connecting the Remote Control to the unit or the Remote Control will not operate Once the unit has been turned ON using the Remote Contro...

Page 19: ...hat high quality shielded antenna cable is used Do not use the inverter to operate high power appliances or tools at the same time you are using it to operate the TV Make sure the inverter s case is p...

Page 20: ...15 5 0 Low Voltage Alarm 10 5 0 3 volts DC 10 5 0 3 volts DC 10 5 0 3 volts DC 10 5 0 3 volts DC 10 5 0 Low Voltage Shutdown 10 0 0 3 volts DC 10 0 0 3 volts DC 10 0 0 3 volts DC 10 0 0 3 volts DC 10...