"EVO220" - WHOLE HOUSE HEAT RECOVERY UNIT

INSTALLATION AND OPERATING INSTRUCTIONS

Safety Notice

It is important to read this Instruction Manual carefully before installing or using the product.  Following these instruc-

tions will ensure that your ventilation system is installed, commissioned and used properly and continues to operate ef-

fectively.  Vectaire will not be held responsible and will not accept liability for any damage caused to persons or property

through failure to follow the guidance provided in this manual.   It should always be available with the product for easy

reference.

EVO220 - 

5"/125mm spigot,  max capacity 75 l/sec

-

General Information

The Vectaire EVO220 heat recovery system provides whole house mechanical

ventilation to living areas, bedrooms, kitchen and bathrooms.  It extracts stale,

contaminated air from kitchens, utility rooms and bathrooms, and uses the heat

recovered from this air to warm fresh, incoming air to create a flow of fresh

air throughout the dwelling.  The extract and intake air streams are separated

to avoid contamination.
The system will operate continuously to create a stable, comfortable, healthy

environment avoiding the use of excessive energy and saving heat already gen-

erated.
The heat recovery unit will generally be installed in the loft of a house or the void

above the ceiling in an apartment (but may be installed in a cupboard) and will

be connected by hidden ductwork to vents sited in the ceilings of the rooms

which require ventilation.  Each unit is commissioned individually allowing its per-

formance to be tailored to suit the performance required.  There will be a facility

to boost the extraction rate when desired (e.g when cooking or bathing or pol-

lutant levels rise).  This may be done automatically or manually.  

The system is designed to run continuously and should NOT be switched off

except for maintenance or filter replacement.  It is important to follow the

advice in this user manual and correctly install and maintain the system to ensure a healthy and comfortable indoor

environment. 

Features

•    

whole house heat recovery units giving continuous ventilation in the kitchen and up to five additional wet rooms

    low noise levels

    variable choice low (trickle) speed and boost options for optimum setting at installation

    boost speed can be triggered by a switched live connection from a variety of external devices including:

     -     PIRFF (passive infra red)

*

     -     DRH240 (dynamic remote humidistat)

*

     -     THM (thermostat)

*

     -     a light switch (if more than one light switch is used, 

each one must be a double pole switch)

     

-     a remote switch/pull cord

     or via LCD control panel  

•    Economical EC motor with electronic control plus:

    

Standard control features

     >   Independent motor speed control

           •  

Each motor can be adjusted independently

         •

Trickle, boost and purge speeds can be set at installation

     >   Adjustable over-run timer - 

from 0-90 Minutes, factory set to 0 minutes

     >   Adjustable delay-on timer - 

from 0-5 Minutes, factory set to 2 minutes

     >   Integral frost stat – 

proportionally reduces intake motor speed as temperature falls

     

>   BMS connections

– for remote motor shut off

•    

Installation MUST be carried out by suitably qualified personnel and MUST be in accordance with current IEE 

     regulations

Page 2

Summary of Contents for EVO220DC

Page 1: ...EVO220DC Whole House Heat Recovery Unit with Low Energy DC Motor and LCD control for domestic and commercial use Installation Operating and Maintenance Instructions ...

Page 2: ...nit is commissioned individually allowing its per formance to be tailored to suit the performance required There will be a facility to boost the extraction rate when desired e g when cooking or bathing or pol lutant levels rise This may be done automatically or manually The system is designed to run continuously and should NOT be switched off except for maintenance or filter replacement It is impo...

Page 3: ...r living room The condensation drain must be fitted and if insulated use the equivalent of at least 25mm of insulating material with a thermal conductivity of 0 04 W mK Care should be taken to ensure that ducting is free from blockages before switching on the unit as this may invalidate your guarantee External grilles should be located a minimum of 600mm from any flue outlet in accordance with all...

Page 4: ...50Hz Consumption 0 92Amps The unit is supplied with A mains rated 4 core flexible cord black brown grey green yellow An optional factory fitted 2 cord volt free flexible cord for purge switching A triple pole isolation switch with contact separation of at least 3mm must be used to connect the appliance to the fixed wiring when using the Switched Live Boost controls must not be located within 1 met...

Page 5: ... plastic strap fitted carefully pull out the heat exchanger Caution if this is done during cold weather the heat exchanger may contain water It is advisable to have a plastic bowl available to avoid spillage Lightly clean the faces of the heat exchanger with a vacuum cleaner Replace the heat exchanger carefully by sliding the assembly back into the cabinet Replace the front cover by securing in pl...

Reviews: