Page 4 / 5
221031
Functions and Operations (continued)
● The shut-off delay is the length of time the light will stay at brightness after motion is detected.
● You can set the shut-off delay by rotating the “TIME” Delay knob arrow so it points to the desired time setting (from 5
seconds to 3 minutes). To increase the shut-off delay, turn the knob clockwise. To decrease the shut-off delay, turn the
knob counterclockwise.
Customization Options
Shut-off Delay
Notes:
1. The sensitivity of the motion sensor will increase as the environmental temperature gets cooler. For best
performance, gently clean the lens with a soft cloth every 1 or 2 months to ensure maximum sensitivity.
2. For best performance, install fixture at least 8 feet above the ground. At such a height, the fixture will provide a
detection distance of up to 70 feet at 77 degrees Fahrenheit. (See Fig.6)
3. The sensor detects movement across a detection range of 180 degrees. (See Fig.7)
4. The sensor will be more sensitive to motion across its detection path than motion directly towards it. (See Fig.8)
5. To reduce possible nuisances, do not mount the fixture near a heat source like an air conditioner, vent or furnace
exhaust, or in a direction facing any reflective object or other nearby light source.
4. PC MODE (nighttime operation only)
● In "PC" mode, the light will turn on at full brightness at dusk and remains on until dawn.
5. 3 HOURS (3H) MODE (nighttime operation only)
● In “3H” mode, the light turns to high-level brightness at dusk, and stays on for 3 hours, then it turns to
low-level 30% brightness. It turns to high-level brightness when motion is detected, and stays on as long as
motion continues. When motion is no longer detected, it remains on for the predetermined shut-off delay
time you set (30s/1min/3min), then returns to the low-level 30% brightness automatically.
● The light turns off automatically at dawn.
6. Manual Override (nighttime operation only)
● To temporarily override the settings in
“OFF” or “AUTO”
or “3H” mode for on-demand continuous high-level
brightness at night, turn the wall switch OFF then turn it
ON twice within 3 seconds, the light remains on all night long.
To shift back to “OFF” or “AUTO” or “3H” mode, turn the wall
switch OFF then turn it ON twice within 3 seconds again.
(See Fig.6)
● The light turns off automatically at dawn.
Note: To make sure the above functions operate properly,
always keep the wall switch in the ON position (including
the daytime).
Fig.6
“AUTO” “OFF”
or “3H” Mode
Manual
Override
Manual Override Operation Diagram
Turn wall switch OFF-ON-OFF-ON
in 0.5~3 Seconds
Turn wall switch OFF-ON-OFF-ON
in 0.5~3 Seconds
10'
8.0'
12.0'
70'
Where you install your fixture is important:
Be sure the light is mounted straight on the wall
or eave; otherwise, the detection distance may
be limited.
Fig. 6
Fig. 7
Fig. 8
Motion
Least sensitive
Motion
Most sensitive
Sensor
180˚