background image

3

Vax Careline

0870 606 1248

safety information

2. Safety Information

For Household Use Only

When using the vacuum cleaner, basic safety precautions
should always be observed, including the following:

1.

Only use the vacuum cleaner indoors on dry
surfaces.

2.

Turn off the vacuum cleaner controls before
connecting or disconnecting from the mains supply.

3.

Always unplug the vacuum cleaner before
connecting or disconnecting the vacuum hose and
accessories.

4.

This appliance is not intended for use by persons
(including children) with reduced physical, sensory or
mental capabilities, or lack of experience and
knowledge, unless they have been given supervision
or instruction concerning use of the appliance by a
person responsible for their safety. Children should
be supervised to ensure that they do not play with
the appliance.

5.

Use only as described in this manual.
Use only the manufacturer’s recommended
attachments.

6.

Do not use the vacuum cleaner if it has been
dropped, damaged, left outdoors or dropped into
water. Do not use the vacuum cleaner with a
damaged cord or plug. If the supply cord or plug is
damaged, return the vacuum cleaner to a Vax
Authorised Service Agent or suitably qualified
person for examination, repair or adjustment.

7.

Do not pull or carry by the cord. Do not use the cord
as a handle, close a door on the cord or pull the cord
around sharp edges or corners. Do not run the
vacuum cleaner over the cord. Keep the cord away
from heated surfaces.

8.

Do not handle the plug or vacuum cleaner with wet
hands. Do not use outdoors or on wet surfaces.

9.

Do not put any objects into openings. Do not use
with any openings blocked and do not restrict air
flow. Keep all openings free of dust, lint, hair or
anything that may reduce airflow.

10. Keep hair, loose clothing, fingers and all parts of the

body away from openings and moving parts.

11. Do not pick up hot coals, cigarette butts, matches or

any hot, smoking or burning objects.

12. Do not pick up flammable or combustible materials

(lighter fluid, petrol, kerosene, etc) or use in the
presence of explosive liquids or vapours.

13. Do not vacuum up harmful or toxic material (chlorine

bleach, ammonia, drain cleaner, etc).

14. Do not vacuum up hard or sharp objects such as

glass, nails, screws, coins, etc.

15. Do not use without the filters in place.

16. Take extra care when vacuuming on stairs.

17. Keep vacuuming area well lit.

18. Store the vacuum cleaner indoors in a cool, dry area.

19. Turn off the on/off switch before unplugging the

vacuum cleaner.

20. Use only CE-approved 13 amp extension cords. Non-

approved extension cords may overheat. Care should
be taken to arrange the cord so that the cord cannot
be pulled or tripped over.

WARNING:

Always switch off and unplug the

vacuum cleaner from the electrical outlet

before assembling, opening or emptying the dirt
container, or before connecting/disconnecting the
attachments.

CAUTION:

The vacuum cleaner is a very powerful

unit. Before plugging the cord into the electrical

outlet, make sure the switch is in the ‘off’ position. Hold
the vacuum cleaner firmly when starting and in use.

IMPORTANT:

If the inlet, hose or extension tube is

blocked, switch off the vacuum cleaner and

remove the blockage(s) before re-starting the vacuum
cleaner.

IMPORTANT:

Cleaning filters regularly improves

vacuum performance. Make sure all filters are

replaced back into the vacuum cleaner before using. This
vacuum cleaner is intended for household use only and
not for commercial or industrial use.

PLEASE KEEP THESE INSTRUCTIONS FOR
FURTHER USE.

!

!

!

!

Motor Thermostat

IMPORTANT:

The motor is equipped with a

thermal cut-out. If for any reason, the vacuum

cleaner should over-heat, the thermostat will
automatically turn the unit off. Should this occur,
unplug the vacuum cleaner from the electrical outlet
and turn off the switch. Remove the dirt container
and empty. Clean the filters. Allow the cleaner to cool
for approximately one (1) hour. To re-start, plug into
an electrical outlet and switch back on.

!

Summary of Contents for Mach5 VZL-6015

Page 1: ...ways fully extend the mains cable before use Retain for future reference Vax careline 0870 6061248 Bagless upright 5 1 8 7 9 11 10 15 14 12 13 17 18 19 20 21 25 22 23 24 21 16 6 4 3 2 26 27 Vax model number VZL 6015 VZL 6016 VZL 6015A VZL 6016A VZL 6015AA VZL 6016AA ...

Page 2: ...revent damage to lino parquet and other hard flooring See page 5 details Vax will not be held responsible for damage to hard floors including lino if the customer fails to switch the brush bar off on these surfaces 12 Furniture guard The guard helps prevent cleaner from marking furniture 13 Carpet height adjuster Turn knob to correct setting for height of carpet being cleaned 14 Post motor filter ...

Page 3: ...arette butts matches or any hot smoking or burning objects 12 Do not pick up flammable or combustible materials lighter fluid petrol kerosene etc or use in the presence of explosive liquids or vapours 13 Do not vacuum up harmful or toxic material chlorine bleach ammonia drain cleaner etc 14 Do not vacuum up hard or sharp objects such as glass nails screws coins etc 15 Do not use without the filter...

Page 4: ...ver base Fig 3 3 Using a Phillips screwdriver fasten 3 screws located at the bottom of the upper housing Fig 3 4 Place bottom of dirt container into cleaner body first Pivot container into cleaner body Fig 3 5 Press on dirt container release button while firmly pressing on the container Release button in order for it to return to proper position and lock into place Fig 3 6 Attach Hose Align end of...

Page 5: ...ligning with opposite end of plug and push firmly UNTIL YOU HEAR A SNAP OR A CLICK Fig 3 10 After ends are connected pull on plug to make sure it is securely attached NOTE The plug will only fit together one way If plug is not fitting together check alignment of ends After the plug ends are fully connected the orange tie wrap must be removed Use caution so as NOT TO CUT the black power cord Discar...

Page 6: ...t To turn cleaner ON push ON OFF switch once To turn cleaner OFF push switch again Fig 4 1 The cleaner is shipped with the brushbar in the OFF position To turn the brushbar ON step on the pedal A The indicator B will show red in the Brushbar on window Fig 4 2 Cord Rewind Grasp the end of the plug and pull to release cord from cord reel After desired cord length is reached the cord will lock into p...

Page 7: ...o room put handle in upright position tilt cleaner back on rear wheels and push forward Fig 4 5 Carrying Cleaner The cleaner can also be moved by using the carrying handle Fig 4 6 Handle Positions The handle of your cleaner has three positions upright for storage and when using cleaning tools operating position for general operation on carpet and floors low for reaching under low furniture Step on...

Page 8: ...s shown and will prevent rug from clinging to cleaner Fig 4 11 Continue to lift up nozzle so that when you have reached the edge it is completely off the rug Move cleaner back to start again lower nozzle and use only forward strokes Cleaning Tools Tools allow for cleaning surfaces above the floor and for reaching hard to clean areas The cleaner is ready for tool use when handle is in upright posit...

Page 9: ...ors and carpeted stairs Crevice tool may be used in tight spaces corners and along edges in such places as dresser drawers upholstered furniture stairs and baseboards Extension tubes are used to give extra length to your hose Use them with any of the above tools Floor brush Model VZL 6016 VZL 6016A VZL 6016AA only use on hard surface floors Attach extension tube and tools Attach tool or extension ...

Page 10: ...ectrical outlet Do not use the cleaner without dirt cup or filters in place Press dirt cup release button A and pivot cup out Fig 5 2 Holding dirt cup over trash receptacle press dirt cup door release button A to open dirt cup door Fig 5 3 Close door and press dirt cup door release button to latch dirt cup door closed Place bottom of dirt cup in first Pivot cup into cleaner body Fig 5 4 Press on d...

Page 11: ...top of the housing to the right and pull down to remove gray filter frame Remove black foam filter Rinse filter frame cartridge and foam filter under cold water Allow both filter frame and filter to air dry for 24 hours before replacing filter into filter frame Reposition filter frame cartridge by inserting tabs B into slots on back of housing Rotate filter cartridge frame up toward top of housing...

Page 12: ...he flat wide belt is described below the other belt is described under Brushbar IMPORTANT Disconnect cleaner from electrical outlet Brushbar can start suddenly Unplug cleaner before turning it over To check the flat belt remove bottom plate as shown below Replace belt if it is stretched cut or broken Replacing Flat Belt Disconnect cleaner from electrical outlet Place handle in low position and tur...

Page 13: ... lowest setting Turn cleaner over and remove bottom plate Lift up brushbar and slide V belt A off brushbar Fig 6 9 Inspecting the V belt The V belt is designed to last for a long time and is not normally replaced However if the V belt is cracked gouged or broken it should be replaced Slide flat belt off large pulley as shown previously To remove V belt slide back of belt over pulley A Then firmly ...

Page 14: ...ess the latches on both sides of tool and remove bottom plate A Fig 6 13 Unscrew the two Phillips screws and remove belt guard Fig 6 14 Remove brushbar including end plates A and discard Inspect belt to ensure that it is in good condition If belt is cracked gouged or broken replace it see following section Insert brushbar through belt and position belt over gear teeth B on brushbar Fig 6 15 With c...

Page 15: ...eplaced Remove tool from hose The belt can be seen through the top of the nozzle or by removing the bottom plate and belt guard Fig 6 19 Remove tool from hose Remove bottom plate belt guard and brushbar as described previously Grasp turbine A and pull firmly to remove Remove belt from turbine pulley B Replace with new belt Fig 6 20 With flat sides of turbine retainers A pointing down slide retaine...

Page 16: ...kage Checking Airflow Path Through Hose Inlet Tube on Back of Cleaner Turn cleaner OFF and unplug If blockage can be seen in tube A remove 5 screws using a Phillips screwdriver Pull tube from cleaner remove blockage Fig 7 2 Reposition tube on back of cleaner replace 5 screws Checking Under Hood Turn cleaner OFF and unplug Remove hood belt and brushbar as described in previous section Look into ope...

Page 17: ...e refer to section 7 PROBLEM Cleaner hard to push Cause Incorrect carpet height setting Solution Move carpet height adjuster to higher setting PROBLEM Smoky burning smell detected Cause Belt broken or stretched Solution Replace brushbar as described in Section 6 PROBLEM Powered Hand Tool brushbar won t turn Cause Too much pressure being applied to tool Solution Continue using tool applying light p...

Page 18: ...ecification 10 Technical Specification Voltage 220 240V 50Hz Wattage 1500W Capacity 2 6l Filters Washable pre motor filter assembly HEPA post motor assembly Cord Length 8 3m Weight 10 68kg Subject to technical change without notice ...

Page 19: ...19 Vax Careline 0870 606 1248 This page has been left intentionally blank ...

Page 20: ... with the following Directives Safety 2006 95 EC Low Voltage Directive EMC 2004 108 EC Electromagnetic Compatibility Directive Waste electrical products should not be disposed of with household waste Please recycle where facilities exist Check with your Local Authority or retailer for recycling advice Vax Ltd Kingswood Road Hampton Lovett Droitwich Worcestershire WR9 OQH UK email info vax co uk we...

Reviews: