Installation manual

11 

 

LAN CABLE 

8 PIN LAN FOR PANO 10M 

8 PIN LAN FOR PANO 1M 

HUB CABLE 

HOLDER 

X-ray Exposure Switch Holder 

 

 

SPEAKER BOX 

 

 

 

SWITCH Up/Down 

INDICATOR BOX 

X-ray exposure switch 

Cable for exposure switch 

USB KEY 

Image reconstruction key 

 

3D VIEWER KEY 

Image viewing 3D   

CASE 

Handle table 

Case Wire-1 

BLOCK 

Column Support Block A 

Column Support Block B 

Base Support Block   

Rear fixing Plate 

CAP 

Hole Cap (Silicon) 

Silicon Cap 

30 

WRENCH BOLT 

8*25 4 

8*25 (With ø8Spring&Flat 

Washer) 

8*60 (With ø8Spring&Flat 

Washer) 

8*50 (With ø8Spring&Flat 

Washer) 

3*8 2 

4*8 2 

4*25 4 

4*8 16 

PANORAMA COVER 

Small Disposable Bag 

CARPUS PLATE 

Carpus Plate (With sticker) 

Guide shaft 

Manual USER 

MANUAL 

EasyDent V4 

Ez3D2009 

3-D Dental Imaging 

Exposure Switch Manual 

 

Summary of Contents for PaX-Reve3D

Page 1: ......

Page 2: ......

Page 3: ...cabinet 26 3 5 Wiring each devise and finishing installation 26 3 6 Balancing the equipment 30 Chapter 4 Installing the control box 31 Chapter 5 Technical specifications 37 5 1 Unit technical specifi...

Page 4: ...6 5 3 4 Cephalometric Image Detector 46 5 4 Standard Accessories 47 5 5 Image Viewer programs 47 5 5 1 3D Image Viewer Ez3D2009 Standard 47 5 5 2 3D Image Viewer Ez3D2009 Professional 49 5 5 3 3D Imag...

Page 5: ...this manual for the users to keep better comprehension of their meaning Make sure that you fully understand them and obey the instructions they contain Symbol Message meaning Note This symbol indicat...

Page 6: ...re to ground the system 7 If there is any doubt on operation or condition do NOT install the system until a E WOO customer support team confirms the reliability Guidelines for Protection against Radia...

Page 7: ...a wall and operator uses the system on left Width of Door The width of door is more than 800mm for system movement into X ray room Ground The condition of ground should be balanced for system balance...

Page 8: ...for a dental diagnosis and treatment like Implant let alone the basic panoramic mode 5 Features capability of switching automatically the sensing mode even without mounting and unmounting sensors 6 E...

Page 9: ...Installation manual 7 1 2 General view of the PaX Reve3D...

Page 10: ...tton when a severe fault occurs Its primary use is to protect humans and equipment from a severe injuries and damages z CHIN REST help the patient rest while imaging z X RAY SENSOR Module used to dete...

Page 11: ...and stabilize the whole equipment 1 3 Exposure switch The exposure switch enables you to launch a radiological image acquisition via exposure button from outside the X Ray room You press and hold the...

Page 12: ...tion manual z When repairs are made by manufacturer s engineers and or trained engineers from the manufacturer z When user uses authorized components or approved components 2 2 Parts list supplied Par...

Page 13: ...3D 1 CASE Handle table 3 Case Wire 1 1 BLOCK Column Support Block A 2 Column Support Block B 2 Base Support Block Rear fixing Plate 1 CAP Hole Cap Silicon 3 Silicon Cap 30 WRENCH BOLT 8 25 4 8 25 With...

Page 14: ...nitor delivery status Please check whether the Shock Watch and Tilt Watch on each carton have been damaged before opening the cartons Shock Watch Tilt Watch Warning Please check the color status of Sh...

Page 15: ...D is to be installed is flat and dry Back Left Right Front At least 3 people are needed to carry and install this unit to prevent this product from being damaged and person from being injured Please k...

Page 16: ...14 Procedures 1 Carefully unpack the carton and position the unit as follows That is lay the unit on the floor with the column down for preparing installation 2 Please remove the moving handle using...

Page 17: ...10 fully inside the lower part of column as the arrows indicated below UP Down Underside of lower part of column Rear bracing plate for the base 4 Please assemble the column and the base together Be c...

Page 18: ...quired to do this Think about the unit is too heavy Firmly screw 4 wrench bolts M8 25 Accessory No 11 as stated in the following figure Important one person should grasp the bar pulling the unit towar...

Page 19: ...rom the unit 7 By factory default to prevent the unit from being damaged while shipping and moving the unit the rotating unit and vertical frame are firmly fixed to a particular position using wrench...

Page 20: ...PaX Reve3D 18 8 Please connect the power supply and Up Down switch cables 9 Turn on the unit and move up the column unit by approximately 20cm using the Up Down switch Power supply UP DOWN...

Page 21: ...o work on fastening the frontal part of assembly of column and base Two procedural works are required to fix column and base together with 6 wrench bolts screws M8 25 Wrench bolt 8 Flat washer spring...

Page 22: ...embly into the column and move it up fully so that one end of it falls in the hole Figure 2 Next pull it down through the hole and match the end of it onto the hole on the base Figure 3 Do this proced...

Page 23: ...Installation manual 21 Figure 3 Figure 4 12 Please cover the open area where work has just been done with the base cover in a way that two magnets face down on the base Magnets...

Page 24: ...sor is so susceptible to the physical impacts 1 Do follow these procedures to mount the Cephalometric unit on the column unit Insert the supplied Guide Shaft Assembly into the column and move it up fu...

Page 25: ...e connected to the LAN Hub later ONE72A ONE74A and ONE75A are concerned with connection this time 3 Upon combining A part with B fasten these two units using 2 wrench bolts M8 60 8 flat washer spring...

Page 26: ...PaX Reve3D 24 5 Please install the Case Column Top Assembly Accessory No 05 onto the front side of column Magnets...

Page 27: ...cables from the Touch panel screen through the wire guide hole as indicated in red circle The touch pad screen is supplied with Accessory No 09 2 Then attach the touch pad screen onto the column and...

Page 28: ...ttach the cabinet after adjusting two bolts on the side of the column 3 5 Wiring each devise and finishing installation 1 Connecting wires to the connector panel on the back of column Please connect t...

Page 29: ...s components Connect these various cables ONE72A ONE75A ONE74A and ONE54A to each corresponding component according to the following diagram Always be careful not to plug forcefully 3 The ONE73A cable...

Page 30: ...to those from the column For these works always be careful to not force too much when plugging each other Double check before wiring together and follow the schematic diagram Cable number Cabling name...

Page 31: ...Top using 6 truss bolts M4 8 Accessory No 20 6 Next fasten the Case column power Accessory No 06 using 4 truss bolts M4 8 Accessory No 20 Figure 1 And fix the Column Back Case cover Accessory No 02 t...

Page 32: ...er quality of image The level is required to do this job 1 First place the level on the front top edge of the vertical frame as shown in the figure While observing the level adjust the bolts on both r...

Page 33: ...or the LCD panel and its control box assembly LCD panel optional control box exposure switch 2 Installing control box with the basic configuration Locate the place where control box is to be mounted a...

Page 34: ...connector used to connect control box to the PaX Reve3D B is a 6 pin connector to provide the interoperability of this unit and other equipments making X ray exposure possible with single control box...

Page 35: ...Installation manual 33 Combine the control box with bracket that has already been installed on the wall And screw them with 4 truss bolts M4 10 Works have just finished...

Page 36: ...ptional Locate the place where control box is to be mounted and screw wall mounted type bracket using kal block and tapping crews M4 10 Match the corresponding holes of the control box and the rear br...

Page 37: ...the interoperability of this unit and other equipments making X ray exposure possible with single control box SPK provides communications between the patient and operator through speaker They are phy...

Page 38: ...PaX Reve3D 36 Combine the control box with bracket that has already been installed on the wall And screw them with 4 truss bolts M4 10 Works have just finished...

Page 39: ...s Standard Panoramic Adult Child 13 5 sec 12 0 sec Hemi Panoramic Left and Right 6 8 sec Frontal Dentition 10 6 sec TMJ Open Close mouth 11 2 sec 4 2 8 sec Maxillary Sinus 11 0 sec Cephalometric Exami...

Page 40: ...n Area Panoramic Mode 300 x 148 mm z Pixel Resolution 10 00 lp mm z Gray Level 14 bits 3 Cephalometric imaging detector z Technology Flat panel detector z Active Area 264x 325mm z Pixel Resolution 3 9...

Page 41: ...Installation manual 39 5 1 4 Dimension of beam limiting device...

Page 42: ...PaX Reve3D 40 5 1 5 Dimension of the Unit Unit mm...

Page 43: ...41 5 1 6 Focal spot distance FOD ODD FDD mm Mode FOD ODD FDD Focal Spot to Object Distance Object to Detector Distance Focal Spot to Detector Distance CT 424 3 254 5 678 8 PANO 456 6 149 2 605 8 CEPH...

Page 44: ...designed and produced to meet the following standards EN 60601 1 EN 60601 1 3 EN 60601 2 7 EN 60601 2 28 EN 60601 2 32 EN 60601 1 2 EN 61000 3 2 EN 61000 3 3 EN ISO 9001 EN ISO 13485 5 1 8 Marks Grap...

Page 45: ...V z Tube current 1 22 mA z Focal spot 0 5 mm z Inherent filtration 0 8 mm Al z Added filtration 2 0 mm Al z Total filtration 2 8 mm Al z Filament characteristics 3 5 4 9V 3 5A max filament current z A...

Page 46: ...10mA z High frequency generator constant potential micro processor controlled z Ripple 5 5 z Inverter frequency 36 kHz push pull z Nominal power less than 1 3 KW z High voltage DC z Exposure time Pan...

Page 47: ...5sec 31 0 3 0 3 0 3 High 24 sec 22 Normal 15sec 16 D 80X60 0 2 0 2 0 2 High 24 sec 30 Normal 15sec 17 0 3 0 3 0 3 High 24 sec 18 Normal 15sec 12 I 50X50 0 2 0 2 0 2 High 24 sec 18 Normal 15sec 13 0 3...

Page 48: ...8 200 Normal 15 sec I 50X50 0 2 0 2 0 2 High 24 sec 30 5 252 252 252 Normal 15 sec 0 3 0 3 0 3 High 24 sec 9 04 168 168 168 Normal 15 sec z Frame rate 30 fps z Gray scale 14 bit z Active area 144 mm 2...

Page 49: ...s and three dimensional animating work by loading DICOM format CT image and more z Easy conversions through various rendering method as VR Volume Rendering MIP minIP X ray z More accurate 3 D image by...

Page 50: ...terest ROI Region of Interest Segmentation Draw Mask 3D Picker Mask Overlay Output Capture Pane Region Full screen Print CINE player z Task MPR Rotating axis Move rotate adjust thickness Oblique slice...

Page 51: ...ollowing value added functionality with all functionality at EZ3D2009 Professional z Auto Canal Drawing z Knowledge Info z Auto Cross Sectional z Tooth Detachment 5 5 4 Database File Server 2D Image V...

Page 52: ...ee Draw Line Poly Line Measure Tool Distance Continuous Distance Angle Image Processing Invert Sharpen Film Effect Tool Image Analysis Magnifier Slide Profile Implant Simulation Add Implant Add Implan...

Page 53: ...be reproduced transmitted or transcribed without the expressed written permission of the manufacturer and authors of this manual If you do not properly set the device setting causing the device to mal...

Page 54: ......

Page 55: ......

Page 56: ...PaX Reve3D 52...

Reviews: