INSTALLATION
Series 655
48/112
Edition 23.09.2019
979645EA
4.8.4.1
Pressure ramp configuration
Time Mode (Ramp Mode = Time)
Slope Mode (Ramp Mode = Slope)
The time within Target Pressure Used (ramp) reaches a
new Target Pressure is defined in parameter value
Ramp Time. Ramp Time is a value in the unit [seconds].
After setting a new Target Pressure, Target Pressure
Used will converge the Target Pressure in the slope
defines in parameter Ramp Slope. Ramp Slope is a
value in the unit [pressure / seconds]