INSTALLATION
Series 655
38/112
Edition 23.09.2019
979645EA
4.7
Sensor configuration
4.7.1
Sensor configuration
It’s important to do proper sensor configuration. The valve internally calculates in absolute values, so the
valve has to know what sensors are connected.
Parameter
Description
Available
Set to ‘True’ if a sensor is connected
Enable
Set to ‘True’ if the sensor signal is used for pressure control
Range.Data Unit
Set the pressure data unit of the gauge
Range.Upper Limit Data Value
Range.Lower Limit Data Value
Set the upper limit and lower limit of the gauge in the unit of
“Range.Data Unit”
Example for a 250mTorr linear sensor:
Upper Limit = 250.0
Lower Limit = 0.0
Range.Upper Limit Voltage Value
Range.Lower Limit Voltage Value
These parameters are only used for gauges with analog voltage
interface.
The values corresponds to Range.Upper Limit Data Value and
Range Lower Limit Data Value
Example:
Upper Limit: 10.0V
250mTorr Range Upper Limit Data Value
Lower Limit: 0.0V
0.0mTorr Range Lower Limit Data Value
Range.Scale
Select if a ‘Linear’ or a ‘Logarithmic’ type of gauge is used.
Most gauges are linear type gauges.
Input Source
Select ‘Analog’ if a gauge with analog voltage interface is used.
Select ‘Digital’ if an RS485 gauge is used.
Parameter location:
CPA
DEVICENET
Pressure Sensor.Sensor 1
Pressure Sensor.Sensor 2
Not accessible