background image

5

11.03

Vedolux 30

Illustrations may differ from the actual product 

Allowing for printing errors and errors on proofs

Technical.data

1.  Hot water outlet, riser, 1¼” BPT*.
2.  Hot water outlet, return, 1¼” BPT*.
3.  Flue pipe, standard.
12  Base bolts, adjustable.
13.  Connections for cooling coil, 0.6 in Cu.
14.  Expansion connection, 1” BPT*.
19.  Base frame, accessory.

* Use the delivered NPT adapters for these connections. 

The NPT adapter builds 2.2”.

  Clearance to combustibles.

12” sides and rear, 18” top and 36” front. 

A

58.6

+0.8 -0

13.5

+0.8 -0

34.5

45.1

+0.8 -0

0.8

19.3

34.2

3.7

.8 -0

64.7

61.7

67.7

3.1

49.8

47.6

2

3

12

13

14

1

1

2

13

19

Weight

empty 

filled with water

639 
860

lb 
lb

Volume

26

gal

Design.pressure

22

psi

Test.pressure

31

psi

Pressure.drop

water flow 0.14 gal/s

0.145

psi

Design.temperature

220

°F

Max.operating.temperature

220

°F

Output

wood, moisture content 17 ±3 %

113

kBTU

pellets

137

kBTU

Combustion.chamber

volume

23.8 gal

depth

21.65 in

Length.of.wood

20 in

Burning.cycle.

moisture content 17 ±3%

3-3.5 h

Firewood.hatch

w x h11.8 x 9.7 in

Chimney.requirement

height

11.5 ft

flue duct recommended

Ø 5.71 

25.6

in 
in

2

flue duct

Ø 4 

12,6

in 
in

2

draught -10 / -20 Pa

Flue.gas.temperature

355 °F

Voltage

115 V, 60 Hz

Current

0.3 A

Protection.class

IP21

Boiler.group.as.per.EN.303-5

Class 3

UL391,.CSA-B366.1,.ETLM78-1.
Certified.by.Guardien.Fire.Test.Labs

n

6

15.7

4.8

5.3

n

5.9

4,1

6.3

Summary of Contents for Vedolux 30

Page 1: ...Installation operation and care Vedolux 30 2011 03 31 xxxxxx SMOKELESS...

Page 2: ...ust not do in order to prevent damage or disturbance to the component the burner the process or the surroundings General General 2 Notes 3 Function 4 Vedolux 30 Ceramic combustion chamber Flue cleanin...

Page 3: ...3 Vedolux 30 Illustrationsmaydifferfromtheactualproduct Allowingforprintingerrorsanderrorsonproofs To be completed when the Vedolux 30 is installed Serial number Installation date Installer Tel Other...

Page 4: ...firewood is added Flue cleaning All flue ducts in the boiler are cleaned from the same hatch at the front of the boiler The hatch is hinged and is opened with a single operation The flue ducts are ro...

Page 5: ...7 6 2 3 12 13 14 1 1 2 13 19 Weight empty filled with water 639 860 lb lb Volume 26gal Design pressure 22psi Test pressure 31psi Pressure drop water flow 0 14 gal s 0 145psi Design temperature 220 F M...

Page 6: ...dolux 30 has a suction fan minimizing the chimney require ments Clearance to combustibles 12 sides and rear 18 top and 36 front Flue pipe The boiler is supplied with an angled flue pipe a flue pipe ru...

Page 7: ...with the applicable regulations The boiler has a cooling coil which combined with a suitable thermal valve is used to prevent the boiler temperature exceeding 230 F if the water boils Follow the inst...

Page 8: ...trolled by the thermostat 21 When the firewood is burnt out and the flue gas temperature falls below the value set for the thermostat 21 the fan and charging pump stop running If the boiler temperatur...

Page 9: ...s to fell the tree in spring just after the leaves have come out then wait a few weeks before trimming and splitting the wood During these weeks the leaves wilt and draw out the moisture After another...

Page 10: ...ose the bypass damper Check that you can see flames in the inspection glass Adding wood To prevent smoke and flames entering the room when adding wood you must open the bypass damper before opening th...

Page 11: ...he flue gases One way of telling whether it is time for cleaning is to check the flue gas ther mostat It is a good idea to clean the boiler if the flue gas tempera ture is approx 80 F higher than the...

Page 12: ...system the static head If the difference is 16 4 ft the pressure is 7 3 psi if it is 32 8 ft the pressure is 14 5 psi The necessary pressure in the heating system depends on the height difference bet...

Page 13: ...cboilerisatitsmostefficientwhentheceramicishot The temperatureintheboilerthereforeneedstobeincreasedquicklybefore chargingbegins Theservicelifeoftheboilerisshortenedifthereisno controlsystem Addacontr...

Page 14: ...76 psi 1 5 29 50 05 Cleaning tool bracket 1 30 00 11 Glass fibre cord 10mm m 1 7 30 00 30 Ceramic fibre paper 1x25mm m 1 1 34 31 04 02 Grate front V 30 1 34 31 04 03 Grate rear V 30 1 9 71 05 06 Firew...

Page 15: ......

Page 16: ...4644 226358 291 94 Kristianstad www varmebaronen se Sweden info varmebaronen se V rmebaronen AB retains the right to change the specification of included components without prior notice as part of it...

Reviews: