Vedolux 30

Illustrations may differ from the actual product 

Allowing for printing errors and errors on proofs

Function

Vedolux.30

•  is a firewood boiler with a suction fan, designed for heating houses 

and smaller properties.

•  is environmentally-approved for firewood burning with an accumu-

lator tank.

• is designed for 20 in. firewood.
• is designed to be connected to an external water heater.
•  is primarily designed to be fired by firewood, but can also be modi-

fied for use with a pellet burner.

•  has an output of 113 kBTU when burning firewood and capable of 

137 kBTU when burning pellets.

Ceramic.combustion.chamber

The combustion chamber is designed for reverse combustion. The 
depth of the combustion chamber is 21.7 in. A bypass damper pre-
vents smoke entering the room when firewood is added.

Flue.cleaning

All flue ducts in the boiler are cleaned from the same hatch at the 
front of the boiler. The hatch is hinged and is opened with a single 
operation. The flue ducts are round, which means there are no awk-
ward corners when flue cleaning.

Chimney

The Vedolux 30 has a suction fan minimizing the chimney require-
ments of the boiler.

Accumulator.tank

To optimise combustion and efficiency, and to meet environmental 
requirements relating to firewood burning, the boiler must be con-
nected to an accumulator tank. The accumulator tank is dimensioned 
according to the requirements of the building.

Delivery

The product is delivered with the following components:
• flue pipe.
• flue cleaning tool with bracket.
• flue gas thermometer.
• gas lighter.
• 1.5 bar pressure relief valve.
• NPT adapters:   

NPT G15 (½”) x 1 pcs.
NPT G25 (1”) x 2 pcs. 
NPT G32 (1¼”) x 2 pcs.

Accessories

• Stand to make firewood burning more convenient.
• Accumulator Control 3.
• Hatch set for pellet burner

Summary of Contents for Vedolux 30

Page 1: ...Installation operation and care Vedolux 30 2011 03 31 xxxxxx SMOKELESS...

Page 2: ...ust not do in order to prevent damage or disturbance to the component the burner the process or the surroundings General General 2 Notes 3 Function 4 Vedolux 30 Ceramic combustion chamber Flue cleanin...

Page 3: ...3 Vedolux 30 Illustrationsmaydifferfromtheactualproduct Allowingforprintingerrorsanderrorsonproofs To be completed when the Vedolux 30 is installed Serial number Installation date Installer Tel Other...

Page 4: ...firewood is added Flue cleaning All flue ducts in the boiler are cleaned from the same hatch at the front of the boiler The hatch is hinged and is opened with a single operation The flue ducts are ro...

Page 5: ...7 6 2 3 12 13 14 1 1 2 13 19 Weight empty filled with water 639 860 lb lb Volume 26gal Design pressure 22psi Test pressure 31psi Pressure drop water flow 0 14 gal s 0 145psi Design temperature 220 F M...

Page 6: ...dolux 30 has a suction fan minimizing the chimney require ments Clearance to combustibles 12 sides and rear 18 top and 36 front Flue pipe The boiler is supplied with an angled flue pipe a flue pipe ru...

Page 7: ...with the applicable regulations The boiler has a cooling coil which combined with a suitable thermal valve is used to prevent the boiler temperature exceeding 230 F if the water boils Follow the inst...

Page 8: ...trolled by the thermostat 21 When the firewood is burnt out and the flue gas temperature falls below the value set for the thermostat 21 the fan and charging pump stop running If the boiler temperatur...

Page 9: ...s to fell the tree in spring just after the leaves have come out then wait a few weeks before trimming and splitting the wood During these weeks the leaves wilt and draw out the moisture After another...

Page 10: ...ose the bypass damper Check that you can see flames in the inspection glass Adding wood To prevent smoke and flames entering the room when adding wood you must open the bypass damper before opening th...

Page 11: ...he flue gases One way of telling whether it is time for cleaning is to check the flue gas ther mostat It is a good idea to clean the boiler if the flue gas tempera ture is approx 80 F higher than the...

Page 12: ...system the static head If the difference is 16 4 ft the pressure is 7 3 psi if it is 32 8 ft the pressure is 14 5 psi The necessary pressure in the heating system depends on the height difference bet...

Page 13: ...cboilerisatitsmostefficientwhentheceramicishot The temperatureintheboilerthereforeneedstobeincreasedquicklybefore chargingbegins Theservicelifeoftheboilerisshortenedifthereisno controlsystem Addacontr...

Page 14: ...76 psi 1 5 29 50 05 Cleaning tool bracket 1 30 00 11 Glass fibre cord 10mm m 1 7 30 00 30 Ceramic fibre paper 1x25mm m 1 1 34 31 04 02 Grate front V 30 1 34 31 04 03 Grate rear V 30 1 9 71 05 06 Firew...

Page 15: ......

Page 16: ...4644 226358 291 94 Kristianstad www varmebaronen se Sweden info varmebaronen se V rmebaronen AB retains the right to change the specification of included components without prior notice as part of it...

Reviews: