background image

2

11.03

Vedolux 30

Illustrations may differ from the actual product 

Allowing for printing errors and errors on proofs

Contents

Read this document carefully before carrying out any installation, 

adjustment or service – and follow the instructions.

Keep these instructions close to the boiler!
The boiler must not be modified, changed or rebuilt.
To  guarantee  high  reliability,  all  installation,  adjustment  and 
ongoing service must be carried out correctly.
The correct settings are important for economical heating.
The type and serial number of the boiler must be quoted whenever 
you contact your retailer, see the rating plate.
For service issues, contact your installer.
Värmebaronen AB retains the right to change the specification 
without  prior  notice,  as  part  of  its  policy  of  continuous 
improvement and development.

You may see the following symbols in these instructions and on the 

product:

 

Information that is important for optimum function.

  Tells you what you must – or must not – do in order to 

avoid personal injury.

  Tells you what you must – or must not – do in order to 

prevent damage or disturbance to the component, the 
burner, the process or the surroundings.

General

General.............................................................................................2
Notes.................................................................................................3
Function............................................................................................4

Vedolux 30 
Ceramic combustion chamber 
Flue cleaning 
Chimney 
Accumulator tank 
Delivery 
Accessories
T

echnical.data..................................................................................5

Installation........................................................................................6

Chimney 
Flue pipe 
Flue gas thermometer 
Connection to accumulator system 
Function of accumulator control 
Ex pansion system 

Vented 
Unvented

Cooling coil - temperature limiter 
Turbulators 
Bracket for cleaning tool 
Draught hatch 
Pellet burner/oil burner

Electrical.connection.......................................................................8

Electrical connection

Wiring.diagram.and.control.panel..................................................8

Function

Checks..............................................................................................9

Firewood...........................................................................................9

Firewood as a fuel 
Firewood 
Heat content 
First burning cycle

Firewood.as.a.fuel...........................................................................10

First burning cycle 
Lighting a fire without gas 
Lighting a fire with the gas lighter 
Adding wood 
Bypass damper 
Controlling combustion

Cleaning............................................................................................11

Cleaning the boiler 
Chimney sweeping 
Cleaning the fan

Operation.and.care..........................................................................12

Ceramic - combustion tunnel 
Safety valves 
Venting 
Water pressure in the system 
Unvented expansion system 
Overheating protection 
If there is a risk of freezing 
Draining the boiler 
Boiler cleaning 
Pellet burner 
Power failure

Problems.burning.firewood............................................................13
Component.specification................................................................14

Summary of Contents for Vedolux 30

Page 1: ...Installation operation and care Vedolux 30 2011 03 31 xxxxxx SMOKELESS...

Page 2: ...ust not do in order to prevent damage or disturbance to the component the burner the process or the surroundings General General 2 Notes 3 Function 4 Vedolux 30 Ceramic combustion chamber Flue cleanin...

Page 3: ...3 Vedolux 30 Illustrationsmaydifferfromtheactualproduct Allowingforprintingerrorsanderrorsonproofs To be completed when the Vedolux 30 is installed Serial number Installation date Installer Tel Other...

Page 4: ...firewood is added Flue cleaning All flue ducts in the boiler are cleaned from the same hatch at the front of the boiler The hatch is hinged and is opened with a single operation The flue ducts are ro...

Page 5: ...7 6 2 3 12 13 14 1 1 2 13 19 Weight empty filled with water 639 860 lb lb Volume 26gal Design pressure 22psi Test pressure 31psi Pressure drop water flow 0 14 gal s 0 145psi Design temperature 220 F M...

Page 6: ...dolux 30 has a suction fan minimizing the chimney require ments Clearance to combustibles 12 sides and rear 18 top and 36 front Flue pipe The boiler is supplied with an angled flue pipe a flue pipe ru...

Page 7: ...with the applicable regulations The boiler has a cooling coil which combined with a suitable thermal valve is used to prevent the boiler temperature exceeding 230 F if the water boils Follow the inst...

Page 8: ...trolled by the thermostat 21 When the firewood is burnt out and the flue gas temperature falls below the value set for the thermostat 21 the fan and charging pump stop running If the boiler temperatur...

Page 9: ...s to fell the tree in spring just after the leaves have come out then wait a few weeks before trimming and splitting the wood During these weeks the leaves wilt and draw out the moisture After another...

Page 10: ...ose the bypass damper Check that you can see flames in the inspection glass Adding wood To prevent smoke and flames entering the room when adding wood you must open the bypass damper before opening th...

Page 11: ...he flue gases One way of telling whether it is time for cleaning is to check the flue gas ther mostat It is a good idea to clean the boiler if the flue gas tempera ture is approx 80 F higher than the...

Page 12: ...system the static head If the difference is 16 4 ft the pressure is 7 3 psi if it is 32 8 ft the pressure is 14 5 psi The necessary pressure in the heating system depends on the height difference bet...

Page 13: ...cboilerisatitsmostefficientwhentheceramicishot The temperatureintheboilerthereforeneedstobeincreasedquicklybefore chargingbegins Theservicelifeoftheboilerisshortenedifthereisno controlsystem Addacontr...

Page 14: ...76 psi 1 5 29 50 05 Cleaning tool bracket 1 30 00 11 Glass fibre cord 10mm m 1 7 30 00 30 Ceramic fibre paper 1x25mm m 1 1 34 31 04 02 Grate front V 30 1 34 31 04 03 Grate rear V 30 1 9 71 05 06 Firew...

Page 15: ......

Page 16: ...4644 226358 291 94 Kristianstad www varmebaronen se Sweden info varmebaronen se V rmebaronen AB retains the right to change the specification of included components without prior notice as part of it...