8
Värmebaronen EP 350
Operation and maintenance
red indicator
Off: normal.
Flashing: serious fault.
The screen shows the cause when
is pressed.
yellow indicator
Off: normal.
Flashing: warning.
The screen shows the cause when
is pressed.
green indicator
On: normal.
Flashing: something is preventing power increase/de-
crease.
The screen shows the cause when
is pressed.
START
Used to restart the boiler after a power cut.
STOP
Breaks the power supply to the boiler by tripping the
boiler's load-break switch.
The voltage to the control circuit is not broken.
Control panel
moves the index arrow upwards between the lines con-
taining parameters that can be changed.
Set/change the content with the UP/DOWN arrow.
Parameters with a large setting range have a fast move
function when the button has been pressed for a while.
moves the index arrow downwards between the lines
containing parameters that can be changed.
Set/change the content with the UP/DOWN arrow.
Parameters with a large setting range have a fast move
function when the button has been pressed for a while.
Press the RIGHT arrow to select the highlighted line.
Set/change the content with the UP/DOWN arrow.
-
Confirms a change and jumps back to the current menu.
Changes made take immediate effect when you press
OK.
Screen
Shows status, alarms, etc. The screen returns to the Operat-
ing menu a minute after any button has been pressed.
Manometer
Shows the water pressure in the boiler/heating system.
START
STOP
VÄRMEBARONEN AB
EP350-....-....
VERS 1.09
(ENGLISH)
>>>>>>>>>><<<<<<<<<<