Värmebaronen EK 13

Electrical installation

27

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

17

18

21

22

23

24

25

26

41 31 21

42 32 22

30-90 °C

31 21 11

32 22 12

N

102 °C

N

6 kW

4 kW

3 kW

41 31 21 11

42 32 22 12 30-90 °C

L1L2L3

1122

F N N

230V~

6 kW

20

19

1. Terminal block.
2. Power cable connection.
3. Power supply, circulation pump, 230 V~.
4. Blocking, power stage one.
5. All-pole switch.
6. Operation indicator.
7. Miniature circuit breaker for control and circulation pump.
8. Overheating protection.
9. Contactor, blocking, power stage one.
10. Thermostat, power stage one.
11. Indicator, power stage one.
12. Electric elements, power group one, 6 kW.
13. Electric elements, power group two, 4 kW.
14. Electric elements, power group three, 3 kW.
15. Indicator, power stage two.
16. Indicator, power stage three.
17. Thermostat, power stages two and three.

18. Printed circuit board.
19. Relay group, power stage two.
20. Relay group, power stage three.
21.  Selection of connection delay:

Jumpered: power stages two and three delayed for two hours
(standard).
Unjumpered: power stage three delayed for two hours.

22.  Neutral for the electronics. The incoming control phase for the

circuit board comes via relay group no. 19, connection no. 4.

23. Selection of connection delay, one or two hours.
24.  The two-hour lock may be disabled by short-circuiting the pins

until LED no. 26 goes out.

25.  Connection of load guard or other external blocking:

closure 1 - 2, relay group no. 19 picked up.
closure 2 - 3, relay group no. 20 picked up.

26.  LED, flashes when the two-hour lock is operating, normally off.
27. Connection pin for power groups on immersion heater.

Summary of Contents for EK 13

Page 1: ...2 1 1 2 2 0 1 1 Installation and maintenance Electric cartridge EK 13...

Page 2: ...External blocking Connection delay after power cut Limitation of power Load guard Electrical installation wiring diagram 7 Control panel 8 Operation and maintenance 8 General Operation Overheating pro...

Page 3: ...3 V rmebaronen EK 13 Tel Notes Production number Installation date Installer Other To be completed when the cartridge is installed...

Page 4: ...n free The system must be leakproof so that the water does not need to be replaced with new oxygen rich water and the water is not oxygenated during installation Water quality in respect of suitable t...

Page 5: ...oxygenation of the heating system Closed system The cartridge is connected to a closed expansion tank and in an unbroken uninterruptible connection to a type approved safety valve with maximum 3 bar...

Page 6: ...rating mode and open in idle mode 25 4 1 To external control unit Connection delay after power cut The electric cartridge has connection delayed power stages after a power cut according to the standar...

Page 7: ...ower group three 3 kW 15 Indicator power stage two 16 Indicator power stage three 17 Thermostat power stages two and three 18 Printed circuit board 19 Relay group power stage two 20 Relay group power...

Page 8: ...Otherwise it works in the same way as the thermostat for power stage one Overheating protection The electric cartridge has overheating protection that is triggered when the temperature exceeds approxi...

Page 9: ...circuit is Take action Then reset the miniature circuit breaker Operating indicators for stages two and three off Stage one on Miniature circuit breaker on circuit board triggered Check where the sho...

Page 10: ...e EK 13 1 1 160003 12 pole terminal block 1 160006 End plate 1 160009 2 pole bridge 2 160011 4 pole bridge 1 9 170046 Contactor 230 V 1 7 180021 Miniature circuit breaker 10 A 1 11 15 16 190002 Indica...

Page 11: ......

Page 12: ...V rmebaronen AB Arkelstorpsv gen 88 SE 291 94 Kristianstad Tel 46 44 22 63 20 Fax 46 44 22 63 58 www varmebaronen se www varmebaronen com info varmebaronen se...

Reviews: