TECHNICAL DATA
Voltage/frequency:
230 V ~ 50 Hz (Phase-Neutral-Earth)
Heat pump output: (with SC10GHH compressor / with BSD122 DT compressor)
1,4 kW / 1,7 kW
Heat pump input: (with SC10GHH compressor / with BSD122 DT compressor)
395 W / 600 W
High supplementary heating:
2,0 kW / 230 V
Fuse protection:
> 13 A
Thermostat for supplementary heating:
Bei 65
°
C, Controlled via the display
Protection:
IP20
Water temperature:
Adjustable - max. 62
°
C
Refrigerant:
R 134 a (CH
2
FCF
3
)
Amount of refrigerant:
0,990 Kg or see name plate
Leak tested:
Air temperature:
-10
°
C to +35
°
C
Air flow:
200 to 300 m3/h
Stock temperature:
-20
°
C bis +60
°
C
External pressure in ventilation system without affecting the performance:
80 Pa (Fan speed 1)
Boiler – VT3130 / VT3130 ECO / VT2130:
270 l, Enamelled
Boiler – VT3131 / VT3131 ECO / VT2131:
258 l, Enamelled
Boiler – VT3132 / VT3132 ECO / VT2132:
242 l, Enamelled
Anode:
5/4” RT
Pressure tested:
13 bar / 1.3 MPa
Working pressure:
10 bar / 1 MPa
Max. boiler temperature:
65
°
C
Weight without packaging – VT3130 / VT3131 / VT3132:
145 Kg / 168 Kg / 190 Kg
Weight without packaging – VT3130 ECO / VT3131 ECO / VT3132 ECO:
134 Kg / 157 Kg / 179 Kg
Weight without packaging – VT2130 / VT2131 / VT2132:
152 Kg / 175 Kg / 197 Kg
Weight (full load) – VT3130 / VT3131 / VT3132:
396 Kg / 411 Kg / 417 Kg
Weight (full load) – VT3130 ECO / VT3131 ECO / VT3132 ECO:
384 Kg / 399 Kg / 405 Kg
Weight (full load) – VT2130 / VT2131 / VT2132:
406 Kg / 421 Kg / 427 Kg
Water connections:
Cold water:
1” RT
Hot water:
1” RT
Condensation water:
1/2” RT
Heat exchanger:
1” RT
Cirkulation:
3/4” RT
Heat exchanger, heat surface VT3131 / VT3131 ECO / VT2131:
1.00 m2 (5.90 l)
Heat exchanger, heat surface VT3231 / VT3231 ECO / VT2231:
Lower 1.5m2 (9.57L) +
upper 0.6m2 (3..83 L)
Idle consumption - at 7
°
C outside air and 55
°
C hot water temperature:
27 W / 24 hours*
Idle consumption - at 20
°
C ambient air and 55
°
C hot water temperature:
20 W / 24 hours*
COP:
2.83*
COP:
3,61**
*According to EN16147:2011, XL-Profile, outside air 7
°
C / hot water reference 55
°
C
** According to EN16147:2011, XL-Profile, ambient air 20
°
C / hot water reference 55
°
C