background image

 

Page 35 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Summary of Contents for SaxMag V Series

Page 1: ...V Series Internal Gear Pumps with Magnetic Coupling Operating Manual Ed 2013 03 Rev 00 Code 555...

Page 2: ...27 1 1997 Explosive atmospheres Explosion Protection Part 1 Basic concepts and methodology EN13463 1 2001 Non electrical equipment for potentially explosive atmospheres Part 1 Basic method and require...

Page 3: ...spare parts by customer 8 2 8 Improper modes of operation 8 2 9 Explosion protection 8 2 9 1 Filling the unit 9 2 9 2 Special operating conditions 9 2 9 3 Markings 9 2 9 4 Checking the sense of rotati...

Page 4: ...4 4 Accessories 18 4 5 Dimensions and weights 18 5 Mounting Installation 18 5 1 Safety regulations 18 5 2 Installation 19 5 2 1 Checks 19 5 2 2 ATEX Certification 19 5 3 Checks prior to installation 1...

Page 5: ...mentation If you have any questions or require further information please do not hesitate to consult the manufacturer Pump series size major operating data and the series number are indicated on the r...

Page 6: ...may cause hazards to persons Warning of electric power Safety symbol according to IEC 417 5036 and explosion protection Safety instructions pertaining to machines and their functions are indicated by...

Page 7: ...ions may result in the loss of any and all claims for damages In particular non compliance of safety information may result in the following hazards risks Failure of important machine equipment functi...

Page 8: ...hen the machine stands still It is imperative to follow the shutdown procedure described in this Operating Manual Pumps or pump units that discharge media hazardous to health must be decontaminated Al...

Page 9: ...rmal energy generated in the containment shell or on the external magnet may also cause an inadmissible rise in temperature If such risk exists make sure to take suitable monitoring measures see 4 3 4...

Page 10: ...n the piping The pump must not discharge against a closed system 2 9 6 Temperature limits Under normal operating conditions expect the highest temperatures to occur at the surface of the pump casing t...

Page 11: ...f the antifriction bearings depends on the mode of operation and the specific conditions on site Regular checks of the running noise prevent the risk of excessive temperatures caused by overheated bea...

Page 12: ...ng devices for transport The transport locking devices supplied with the pump can be removed after transport During start up and maintenance ensure safe transport of all components To this end suitabl...

Page 13: ...the filled in liquid might contaminate the product to be pumped Never start up the pump with water and do not leave any traces of water in the pump 3 3 Return Pumps that have delivered corrosive or po...

Page 14: ...to the internal magnet core that is mounted to the pump shaft The magnetic field generated by the motor driven magnet hub with the externally placed set of permanent magnets causes the internal magne...

Page 15: ...rough the pump the point where the teeth come out of mesh governs the phase of the liquid entering between the rotors and is therefore physically located close to the suction zone The liquid is carrie...

Page 16: ...of this Operating Manual 4 3 Main components 4 3 1 Magnetic coupling The external rotor is driven by an electric motor through antifriction bearings It is due to the magnetic forces of the permanent...

Page 17: ...bearing clearance and high temperature grease packing have sealing washers on either side The pump end shaft is supported in hydrodynamic carbide plain bearings which are lubricated by the pumped flui...

Page 18: ...g guard Baseplate welded fabrication for complete to ISO 3661 unit pump and motor of torsionally rigid design Where complete units are delivered the coupling and the coupling guard will be furnished b...

Page 19: ...se as possible to the tank of the liquid to be pumped and allow sufficient space around to facilitate maintenance work inspection and checks Keep enough free space specifically in front of the pump to...

Page 20: ...g system 5 5 Piping Piping connected to the pump must not transmit forces torques or moments to the latter it may be necessary to support connected pipes upstream of the pump Piping must be adequately...

Page 21: ...ssible loads in the technical section Where the liquid can reach high temperatures it must be ensured that expansion joints are installed in the piping Check the motor s electrical connections the bal...

Page 22: ...pumped medium or discharge side clogging Overtemperature resulting from recirculation when the pressure relief valve has operated Operator s failure to conduct checks as necessary Referring to the app...

Page 23: ...a dangerous electrostatic charges which can result in discharge sparks that could ignite a potentially explosive atmosphere are ruled out as trouble to be expected since the thickness of a paint coat...

Page 24: ...tly set or leaking 8 Insufficient suction pressure 9 Worn pump components gears sliding plate 1 Reduce pressure drop 2 Inspect suction line for leaks 3 Check speed contact manufacturer 4 Eliminate lin...

Page 25: ...act the manufacturer High containment shell temperature Excessive viscosity Product flow for cooling interrupted Contact the manufacturer Check filter and design High casing temperature Foreign matter...

Page 26: ...sed as a result of non observance of this manual The specific safety requirements in relation to strong magnetic fields must be strictly observed Persons who have a pacemaker should not be allowed to...

Page 27: ...ed If damaged replace it This also applies to all other pump seals Pull off the pinion 03 with pressed in plain bearing 37 from the cover 04 via the pin 06 Heat the pinion 03 to approx 80 C When the t...

Page 28: ...OPERATING MANUAL SAXMAG V Page 28 9 3 Disassembly of the pump casing 01 Unscrew the screws 44 and pull off the casing 01...

Page 29: ...ring bracket M1 01 On principle the plug in unit should only be separated from the external magnet M2 02 by radial guidance restricted guidance Make sure that the external magnet M2 02 and the contain...

Page 30: ...r M3 12 from the pump shaft M3 08 Separate the internal magnet M2 04 from the pump shaft M3 08 with the help of a suitable pull off device Remove the thrust washer M3 11 from the pump shaft M3 08 Pull...

Page 31: ...th magnet hub M2 01 from the bearing bracket M1 01 in the direction of the external magnet M2 02 Unscrew the bolts M1 08 and dismantle the ball bearing cover M1 02 from the bearing bracket M1 01 Remov...

Page 32: ...ase see the table below for further information Class Pump type V25 2 V30 2 V50 3 V60 2 V70 2 V80 2 V85 2 V100 2 1 0 2 mm 0 2 mm 0 3 mm 0 5 mm 2 0 3 mm 0 5 mm 0 7 mm 0 7 mm 3 0 5 mm 0 7 mm 1 0 mm Pump...

Page 33: ...ontact with liquids subject to labelling requirements under the law on hazardous substances and or dangerous goods If known please state the last medium pumped Prior to shipment provision the pump has...

Page 34: ...Page 34...

Page 35: ...Page 35...

Page 36: ...rd 35129 PADOVA Italy Tel 049 82 94 111 Fax 049 82 94 373 www variscospa com Vendite Italia Tel 049 82 94 111 Fax 049 82 94 373 italia variscospa com International sales Ph 39 049 82 94 111 Fax 39 049...