WARNING
Do not place any heat-generating elements (outlet filters) on the suction side of the de-
vice. Otherwise, dangerous overheating may occur.
6.3. Mechanical assembly of size 2 devices
The size 2 devices are equipped with a quick connection system that allows to make both power and
signal electrical connections on the fixed part, called "base", while the mobile part, called "power", is
applied later.
This allows to work easily during electrical connections without running the risk of damaging the power
part. It also facilitates quick power replacement in case of failure without the need to remove connec-
tions.
To open the device, please follow the instructions shown in the figure and proceed with caution.
In size 2 devices, the earth connection between the base and the power is made by means of four met-
al pins on the power side that engage into four special holes on the base with spring contacts. At the
same time these metal pins serve as a guide for a correct coupling between the base and the heat sink.
PSDrive
16